Cargando…

Envelope Enhancement Increases Cortical Sensitivity to Interaural Envelope Delays with Acoustic and Electric Hearing

Evidence from human psychophysical and animal electrophysiological studies suggests that sensitivity to interaural time delay (ITD) in the modulating envelope of a high-frequency carrier can be enhanced using half-wave rectified stimuli. Recent evidence has shown potential benefits of equivalent ele...

Descripción completa

Detalles Bibliográficos
Autores principales: Hartley, Douglas E. H., Isaiah, Amal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122409/
https://www.ncbi.nlm.nih.gov/pubmed/25093417
http://dx.doi.org/10.1371/journal.pone.0104097
_version_ 1782329348195352576
author Hartley, Douglas E. H.
Isaiah, Amal
author_facet Hartley, Douglas E. H.
Isaiah, Amal
author_sort Hartley, Douglas E. H.
collection PubMed
description Evidence from human psychophysical and animal electrophysiological studies suggests that sensitivity to interaural time delay (ITD) in the modulating envelope of a high-frequency carrier can be enhanced using half-wave rectified stimuli. Recent evidence has shown potential benefits of equivalent electrical stimuli to deaf individuals with bilateral cochlear implants (CIs). In the current study we assessed the effects of envelope shape on ITD sensitivity in the primary auditory cortex of normal-hearing ferrets, and profoundly-deaf animals with bilateral CIs. In normal-hearing animals, cortical sensitivity to ITDs (±1 ms in 0.1-ms steps) was assessed in response to dichotically-presented i) sinusoidal amplitude-modulated (SAM) and ii) half-wave rectified (HWR) tones (100-ms duration; 70 dB SPL) presented at the best-frequency of the unit over a range of modulation frequencies. In separate experiments, adult ferrets were deafened with neomycin administration and bilaterally-implanted with intra-cochlear electrode arrays. Electrically-evoked auditory brainstem responses (EABRs) were recorded in response to bipolar electrical stimulation of the apical pair of electrodes with singe biphasic current pulses (40 µs per phase) over a range of current levels to measure hearing thresholds. Subsequently, we recorded cortical sensitivity to ITDs (±800 µs in 80-µs steps) within the envelope of SAM and HWR biphasic-pulse trains (40 µs per phase; 6000 pulses per second, 100-ms duration) over a range of modulation frequencies. In normal-hearing animals, nearly a third of cortical neurons were sensitive to envelope-ITDs in response to SAM tones. In deaf animals with bilateral CI, the proportion of ITD-sensitive cortical neurons was approximately a fifth in response to SAM pulse trains. In normal-hearing and deaf animals with bilateral CI the proportion of ITD sensitive units and neural sensitivity to ITDs increased in response to HWR, compared with SAM stimuli. Consequently, novel stimulation strategies based on envelope enhancement may prove beneficial to individuals with bilateral cochlear implants.
format Online
Article
Text
id pubmed-4122409
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-41224092014-08-12 Envelope Enhancement Increases Cortical Sensitivity to Interaural Envelope Delays with Acoustic and Electric Hearing Hartley, Douglas E. H. Isaiah, Amal PLoS One Research Article Evidence from human psychophysical and animal electrophysiological studies suggests that sensitivity to interaural time delay (ITD) in the modulating envelope of a high-frequency carrier can be enhanced using half-wave rectified stimuli. Recent evidence has shown potential benefits of equivalent electrical stimuli to deaf individuals with bilateral cochlear implants (CIs). In the current study we assessed the effects of envelope shape on ITD sensitivity in the primary auditory cortex of normal-hearing ferrets, and profoundly-deaf animals with bilateral CIs. In normal-hearing animals, cortical sensitivity to ITDs (±1 ms in 0.1-ms steps) was assessed in response to dichotically-presented i) sinusoidal amplitude-modulated (SAM) and ii) half-wave rectified (HWR) tones (100-ms duration; 70 dB SPL) presented at the best-frequency of the unit over a range of modulation frequencies. In separate experiments, adult ferrets were deafened with neomycin administration and bilaterally-implanted with intra-cochlear electrode arrays. Electrically-evoked auditory brainstem responses (EABRs) were recorded in response to bipolar electrical stimulation of the apical pair of electrodes with singe biphasic current pulses (40 µs per phase) over a range of current levels to measure hearing thresholds. Subsequently, we recorded cortical sensitivity to ITDs (±800 µs in 80-µs steps) within the envelope of SAM and HWR biphasic-pulse trains (40 µs per phase; 6000 pulses per second, 100-ms duration) over a range of modulation frequencies. In normal-hearing animals, nearly a third of cortical neurons were sensitive to envelope-ITDs in response to SAM tones. In deaf animals with bilateral CI, the proportion of ITD-sensitive cortical neurons was approximately a fifth in response to SAM pulse trains. In normal-hearing and deaf animals with bilateral CI the proportion of ITD sensitive units and neural sensitivity to ITDs increased in response to HWR, compared with SAM stimuli. Consequently, novel stimulation strategies based on envelope enhancement may prove beneficial to individuals with bilateral cochlear implants. Public Library of Science 2014-08-05 /pmc/articles/PMC4122409/ /pubmed/25093417 http://dx.doi.org/10.1371/journal.pone.0104097 Text en © 2014 Hartley, Isaiah http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Hartley, Douglas E. H.
Isaiah, Amal
Envelope Enhancement Increases Cortical Sensitivity to Interaural Envelope Delays with Acoustic and Electric Hearing
title Envelope Enhancement Increases Cortical Sensitivity to Interaural Envelope Delays with Acoustic and Electric Hearing
title_full Envelope Enhancement Increases Cortical Sensitivity to Interaural Envelope Delays with Acoustic and Electric Hearing
title_fullStr Envelope Enhancement Increases Cortical Sensitivity to Interaural Envelope Delays with Acoustic and Electric Hearing
title_full_unstemmed Envelope Enhancement Increases Cortical Sensitivity to Interaural Envelope Delays with Acoustic and Electric Hearing
title_short Envelope Enhancement Increases Cortical Sensitivity to Interaural Envelope Delays with Acoustic and Electric Hearing
title_sort envelope enhancement increases cortical sensitivity to interaural envelope delays with acoustic and electric hearing
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122409/
https://www.ncbi.nlm.nih.gov/pubmed/25093417
http://dx.doi.org/10.1371/journal.pone.0104097
work_keys_str_mv AT hartleydouglaseh envelopeenhancementincreasescorticalsensitivitytointerauralenvelopedelayswithacousticandelectrichearing
AT isaiahamal envelopeenhancementincreasescorticalsensitivitytointerauralenvelopedelayswithacousticandelectrichearing