Cargando…

Comparison of Optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic

PURPOSE: We aimed to assess the agreement between clinical assessment of diabetic retinopathy and Optomap ultrawide-field imaging (UWFI) in a real-life clinic setting. METHODS: Structured examination findings, from diabetic patients attending routine medical retina clinics in July 2011, were retrosp...

Descripción completa

Detalles Bibliográficos
Autores principales: Purbrick, Robert M J, Izadi, Shahrnaz, Gupta, Ankur, Chong, N Victor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122561/
https://www.ncbi.nlm.nih.gov/pubmed/25114501
http://dx.doi.org/10.2147/OPTH.S66700
_version_ 1782329371188527104
author Purbrick, Robert M J
Izadi, Shahrnaz
Gupta, Ankur
Chong, N Victor
author_facet Purbrick, Robert M J
Izadi, Shahrnaz
Gupta, Ankur
Chong, N Victor
author_sort Purbrick, Robert M J
collection PubMed
description PURPOSE: We aimed to assess the agreement between clinical assessment of diabetic retinopathy and Optomap ultrawide-field imaging (UWFI) in a real-life clinic setting. METHODS: Structured examination findings, from diabetic patients attending routine medical retina clinics in July 2011, were retrospectively compared with the grade obtained from Optomap UWFI images, graded independently by two ophthalmologists, taken at the same visit. RESULTS: A total of 84 eyes (42 patients) were examined, and 74 eyes (37 patients) were suitable for analysis. The hospital Eye Service slit-lamp biomicroscopy grades for retinopathy were: no diabetic retinopathy in zero eyes; background retinopathy in 21 eyes; preproliferative retinopathy in 34 eyes; and proliferative retinopathy in 19 eyes. For retinopathy, the agreement between the Optomap UWFI and clinical grading was moderate for both graders (κ=0.57 and κ=0.63), and there was almost perfect agreement between the two graders (κ=0.92). The clinical grades for the presence of photocoagulation scars were: no photocoagulation scars in 46 eyes and photocoagulation scars visible in 28 eyes, indicating substantial agreement between the Optomap UWFI and clinical grading for both graders (κ=0.73 and κ=0.64). There were two instances where proliferative retinopathy was documented clinically but graded as preproliferative by both graders of Optomap UWFI. These were investigated, and neither patient required treatment, ie, the difference in retinopathy grade would not have affected the patient outcomes. CONCLUSION: This study demonstrated moderate agreement between Optomap UWFI and hospital slit-lamp biomicroscopy grading of patients’ retinopathy in a real-life medical retina clinic setting. The authors believe that Optomap UWFI is, not only a very useful adjunct to clinical examination in terms of detection and recording of retinopathy, but also, could have a role in standalone “virtual” clinics.
format Online
Article
Text
id pubmed-4122561
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-41225612014-08-11 Comparison of Optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic Purbrick, Robert M J Izadi, Shahrnaz Gupta, Ankur Chong, N Victor Clin Ophthalmol Original Research PURPOSE: We aimed to assess the agreement between clinical assessment of diabetic retinopathy and Optomap ultrawide-field imaging (UWFI) in a real-life clinic setting. METHODS: Structured examination findings, from diabetic patients attending routine medical retina clinics in July 2011, were retrospectively compared with the grade obtained from Optomap UWFI images, graded independently by two ophthalmologists, taken at the same visit. RESULTS: A total of 84 eyes (42 patients) were examined, and 74 eyes (37 patients) were suitable for analysis. The hospital Eye Service slit-lamp biomicroscopy grades for retinopathy were: no diabetic retinopathy in zero eyes; background retinopathy in 21 eyes; preproliferative retinopathy in 34 eyes; and proliferative retinopathy in 19 eyes. For retinopathy, the agreement between the Optomap UWFI and clinical grading was moderate for both graders (κ=0.57 and κ=0.63), and there was almost perfect agreement between the two graders (κ=0.92). The clinical grades for the presence of photocoagulation scars were: no photocoagulation scars in 46 eyes and photocoagulation scars visible in 28 eyes, indicating substantial agreement between the Optomap UWFI and clinical grading for both graders (κ=0.73 and κ=0.64). There were two instances where proliferative retinopathy was documented clinically but graded as preproliferative by both graders of Optomap UWFI. These were investigated, and neither patient required treatment, ie, the difference in retinopathy grade would not have affected the patient outcomes. CONCLUSION: This study demonstrated moderate agreement between Optomap UWFI and hospital slit-lamp biomicroscopy grading of patients’ retinopathy in a real-life medical retina clinic setting. The authors believe that Optomap UWFI is, not only a very useful adjunct to clinical examination in terms of detection and recording of retinopathy, but also, could have a role in standalone “virtual” clinics. Dove Medical Press 2014-07-29 /pmc/articles/PMC4122561/ /pubmed/25114501 http://dx.doi.org/10.2147/OPTH.S66700 Text en © 2014 Purbrick et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Purbrick, Robert M J
Izadi, Shahrnaz
Gupta, Ankur
Chong, N Victor
Comparison of Optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic
title Comparison of Optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic
title_full Comparison of Optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic
title_fullStr Comparison of Optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic
title_full_unstemmed Comparison of Optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic
title_short Comparison of Optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic
title_sort comparison of optomap ultrawide-field imaging versus slit-lamp biomicroscopy for assessment of diabetic retinopathy in a real-life clinic
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122561/
https://www.ncbi.nlm.nih.gov/pubmed/25114501
http://dx.doi.org/10.2147/OPTH.S66700
work_keys_str_mv AT purbrickrobertmj comparisonofoptomapultrawidefieldimagingversusslitlampbiomicroscopyforassessmentofdiabeticretinopathyinareallifeclinic
AT izadishahrnaz comparisonofoptomapultrawidefieldimagingversusslitlampbiomicroscopyforassessmentofdiabeticretinopathyinareallifeclinic
AT guptaankur comparisonofoptomapultrawidefieldimagingversusslitlampbiomicroscopyforassessmentofdiabeticretinopathyinareallifeclinic
AT chongnvictor comparisonofoptomapultrawidefieldimagingversusslitlampbiomicroscopyforassessmentofdiabeticretinopathyinareallifeclinic