Cargando…
Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis
Percutaneous transosseous Ilizarov wiring, whilst preferred in the tibia because of its unique properties, carries a high risk of complications in the femur. The aim of this work was to evaluate the efficacy of a more patient-friendly semicircular pin external fixator module built up from parts of t...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Milan
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122683/ https://www.ncbi.nlm.nih.gov/pubmed/25070587 http://dx.doi.org/10.1007/s11751-014-0199-6 |
_version_ | 1782329379140927488 |
---|---|
author | Khanfour, Ashraf A. El-Sayed, Mohamed M. |
author_facet | Khanfour, Ashraf A. El-Sayed, Mohamed M. |
author_sort | Khanfour, Ashraf A. |
collection | PubMed |
description | Percutaneous transosseous Ilizarov wiring, whilst preferred in the tibia because of its unique properties, carries a high risk of complications in the femur. The aim of this work was to evaluate the efficacy of a more patient-friendly semicircular pin external fixator module built up from parts of the Ilizarov fixator components and its use in managing diaphyseal femoral nonunions. A group of 20 patients with infected diaphyseal nonunions of the femur after internal osteosynthesis were included in this study. The mean age of the patients at the time of surgery was 46 years (range 16–60, SD 15.6). The mean morbidity time since the original trauma was 10.2 months (range 6–15, SD 2.5). All the cases were fixed by the described external fixator module. Bony union with resolution of infection occurred in 18 (94.7 %) out of 19 cases after a mean period in the fixator of 11.2 months (range 8–18 SD 2.9). After a mean follow-up period of 3.5 years (range 2–9, SD 2.6), there were 14 excellent, 3 good, 1 fair and 1 poor results from radiological evaluation and 10 excellent, 7 good, 1 fair and 1 poor results from functional assessment. In conclusion, the described semi-circular pin fixator module is patient-friendly and effective in managing infected nonunions of the femoral diaphysis. |
format | Online Article Text |
id | pubmed-4122683 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer Milan |
record_format | MEDLINE/PubMed |
spelling | pubmed-41226832014-08-18 Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis Khanfour, Ashraf A. El-Sayed, Mohamed M. Strategies Trauma Limb Reconstr Original Article Percutaneous transosseous Ilizarov wiring, whilst preferred in the tibia because of its unique properties, carries a high risk of complications in the femur. The aim of this work was to evaluate the efficacy of a more patient-friendly semicircular pin external fixator module built up from parts of the Ilizarov fixator components and its use in managing diaphyseal femoral nonunions. A group of 20 patients with infected diaphyseal nonunions of the femur after internal osteosynthesis were included in this study. The mean age of the patients at the time of surgery was 46 years (range 16–60, SD 15.6). The mean morbidity time since the original trauma was 10.2 months (range 6–15, SD 2.5). All the cases were fixed by the described external fixator module. Bony union with resolution of infection occurred in 18 (94.7 %) out of 19 cases after a mean period in the fixator of 11.2 months (range 8–18 SD 2.9). After a mean follow-up period of 3.5 years (range 2–9, SD 2.6), there were 14 excellent, 3 good, 1 fair and 1 poor results from radiological evaluation and 10 excellent, 7 good, 1 fair and 1 poor results from functional assessment. In conclusion, the described semi-circular pin fixator module is patient-friendly and effective in managing infected nonunions of the femoral diaphysis. Springer Milan 2014-07-29 2014-08 /pmc/articles/PMC4122683/ /pubmed/25070587 http://dx.doi.org/10.1007/s11751-014-0199-6 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Article Khanfour, Ashraf A. El-Sayed, Mohamed M. Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis |
title | Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis |
title_full | Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis |
title_fullStr | Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis |
title_full_unstemmed | Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis |
title_short | Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis |
title_sort | efficacy of a compliant semicircular ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122683/ https://www.ncbi.nlm.nih.gov/pubmed/25070587 http://dx.doi.org/10.1007/s11751-014-0199-6 |
work_keys_str_mv | AT khanfourashrafa efficacyofacompliantsemicircularilizarovpinfixatormodulefortreatinginfectednonunionofthefemoraldiaphysis AT elsayedmohamedm efficacyofacompliantsemicircularilizarovpinfixatormodulefortreatinginfectednonunionofthefemoraldiaphysis |