Cargando…

Effect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma

PURPOSE: To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS: I...

Descripción completa

Detalles Bibliográficos
Autores principales: Nilforushan, Naveed, Parsamanesh, Mohammad, Yu, Fei, Nassiri, Nariman, Miraftabi, Arezoo, Coleman, Anne L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4123272/
https://www.ncbi.nlm.nih.gov/pubmed/25100904
http://dx.doi.org/10.4103/0974-9233.134671
Descripción
Sumario:PURPOSE: To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS: In this prospective comparative case series, phacoemulsification with implantation of yellow-tinted Acrysof Natural IOL was performed in 16 eyes of 16 patients with visually significant cataract (best-corrected visual acuity (VA) better than 20/120) and mild to moderate glaucoma. Pre- and postoperative values for VA and for perimetry indices including mean deviation (MD), pattern standard deviation (PSD), and foveal threshold (FT) from both SAP and SWAP testing were compared. RESULTS: Postoperative VA improved significantly after cataract surgery and yellow-tinted IOL implantation (P < 0.001). After cataract extraction and IOL implantation, MD and FT on SWAP testing improved significantly (P = 0.001); however, there was no statistically significant change with SAP testing between the pre- and postoperative perimetry indices. There was no statistically significant change in PSD with either SAP or SWAP testing postoperatively. The differences between pre- and postoperative values for all perimetry indices under study were not significant when comparing SAP with SWAP tests, except for MD which had improved statistically significantly in SWAP testing (P = 0.03). CONCLUSIONS: In mild to moderate glaucoma patients with cataracts, the perimetry indices of SWAP testing improved after phacoemulsification and yellow-tinted IOL implantation. This suggests that the yellow-tinted IOLs have less effect on SWAP testing than visually significant cataracts.