The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation

BACKGROUND: Due to the advantages of its bone-conserving nature, hip resurface arthroplasty (HRA) has recently gained the interest of orthopedic surgeons for the treatment of young and active patients who have osteonerosis of the femoral head. However, in long-term follow-up studies after HRA, narro...

Descripción completa

Detalles Bibliográficos
Autores principales: Tai, Ching-Lung, Chen, Yung-Chou, Hsieh, Pang-Hsin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4124961/
https://www.ncbi.nlm.nih.gov/pubmed/25095740
http://dx.doi.org/10.1186/1471-2474-15-262
_version_ 1782329699071950848
author Tai, Ching-Lung
Chen, Yung-Chou
Hsieh, Pang-Hsin
author_facet Tai, Ching-Lung
Chen, Yung-Chou
Hsieh, Pang-Hsin
author_sort Tai, Ching-Lung
collection PubMed
description BACKGROUND: Due to the advantages of its bone-conserving nature, hip resurface arthroplasty (HRA) has recently gained the interest of orthopedic surgeons for the treatment of young and active patients who have osteonerosis of the femoral head. However, in long-term follow-up studies after HRA, narrowing of the femoral neck has often been found, which may lead to fracture. This phenomenon has been attributed to the stress alteration (stress shielding). Studies addressing the effects of necrotic size and the orientation of the implant on stress alterations are lacking. METHODS: Computed tomography images of a standard composite femur were used to create a three-dimensional finite-element (FE) intact femur model. Based on the intact model, FE models simulating four different levels of necrotic regions (0°, 60°, 100°, 115°) and three different implant insertion angles (varus 10°, neutral, valgus 10°) were created. The von Mises stress distributions and the displacement of the stem tip of each model were analyzed and compared for loading conditions that simulated a single-legged stance. RESULTS: Stress shielding occurred at the femoral neck after HRA. More severe stress shielding and an increased displacement of the stem tip were found for femoral heads that had a wider necrotic lesion. From a biomechanics perspective, the results were consistent with clinical evidence of femoral neck narrowing after HRA. In addition, a varus orientation of the implant resulted in a larger displacement of the stem tip, which could lead to an increased risk of implant loosening. CONCLUSIONS: A femoral head with a wide necrotic lesion combined with a varus orientation of the prosthesis increases the risk of femoral neck narrowing and implant loosening following HRA.
format Online
Article
Text
id pubmed-4124961
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-41249612014-08-08 The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation Tai, Ching-Lung Chen, Yung-Chou Hsieh, Pang-Hsin BMC Musculoskelet Disord Research Article BACKGROUND: Due to the advantages of its bone-conserving nature, hip resurface arthroplasty (HRA) has recently gained the interest of orthopedic surgeons for the treatment of young and active patients who have osteonerosis of the femoral head. However, in long-term follow-up studies after HRA, narrowing of the femoral neck has often been found, which may lead to fracture. This phenomenon has been attributed to the stress alteration (stress shielding). Studies addressing the effects of necrotic size and the orientation of the implant on stress alterations are lacking. METHODS: Computed tomography images of a standard composite femur were used to create a three-dimensional finite-element (FE) intact femur model. Based on the intact model, FE models simulating four different levels of necrotic regions (0°, 60°, 100°, 115°) and three different implant insertion angles (varus 10°, neutral, valgus 10°) were created. The von Mises stress distributions and the displacement of the stem tip of each model were analyzed and compared for loading conditions that simulated a single-legged stance. RESULTS: Stress shielding occurred at the femoral neck after HRA. More severe stress shielding and an increased displacement of the stem tip were found for femoral heads that had a wider necrotic lesion. From a biomechanics perspective, the results were consistent with clinical evidence of femoral neck narrowing after HRA. In addition, a varus orientation of the implant resulted in a larger displacement of the stem tip, which could lead to an increased risk of implant loosening. CONCLUSIONS: A femoral head with a wide necrotic lesion combined with a varus orientation of the prosthesis increases the risk of femoral neck narrowing and implant loosening following HRA. BioMed Central 2014-08-05 /pmc/articles/PMC4124961/ /pubmed/25095740 http://dx.doi.org/10.1186/1471-2474-15-262 Text en Copyright © 2014 Tai et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Tai, Ching-Lung
Chen, Yung-Chou
Hsieh, Pang-Hsin
The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation
title The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation
title_full The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation
title_fullStr The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation
title_full_unstemmed The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation
title_short The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation
title_sort effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4124961/
https://www.ncbi.nlm.nih.gov/pubmed/25095740
http://dx.doi.org/10.1186/1471-2474-15-262
work_keys_str_mv AT taichinglung theeffectsofnecroticlesionsizeandorientationofthefemoralcomponentonstressalterationsintheproximalfemurinhipresurfacingafiniteelementsimulation
AT chenyungchou theeffectsofnecroticlesionsizeandorientationofthefemoralcomponentonstressalterationsintheproximalfemurinhipresurfacingafiniteelementsimulation
AT hsiehpanghsin theeffectsofnecroticlesionsizeandorientationofthefemoralcomponentonstressalterationsintheproximalfemurinhipresurfacingafiniteelementsimulation
AT taichinglung effectsofnecroticlesionsizeandorientationofthefemoralcomponentonstressalterationsintheproximalfemurinhipresurfacingafiniteelementsimulation
AT chenyungchou effectsofnecroticlesionsizeandorientationofthefemoralcomponentonstressalterationsintheproximalfemurinhipresurfacingafiniteelementsimulation
AT hsiehpanghsin effectsofnecroticlesionsizeandorientationofthefemoralcomponentonstressalterationsintheproximalfemurinhipresurfacingafiniteelementsimulation