Cargando…
Comparative analysis of physicochemical properties of root perforation sealer materials
OBJECTIVES: This study evaluated the solubility, dimensional alteration, pH, electrical conductivity, and radiopacity of root perforation sealer materials. MATERIALS AND METHODS: For the pH test, the samples were immersed in distilled water for different periods of time. Then, the samples were retai...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Conservative Dentistry
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4125584/ https://www.ncbi.nlm.nih.gov/pubmed/25110644 http://dx.doi.org/10.5395/rde.2014.39.3.201 |
_version_ | 1782329778653626368 |
---|---|
author | Dorileo, Maura Cristiane Gonçales Orçati Pedro, Fábio Luis Miranda Bandeca, Matheus Coelho Guedes, Orlando Aguirre Villa, Ricardo Dalla Borges, Alvaro Henrique |
author_facet | Dorileo, Maura Cristiane Gonçales Orçati Pedro, Fábio Luis Miranda Bandeca, Matheus Coelho Guedes, Orlando Aguirre Villa, Ricardo Dalla Borges, Alvaro Henrique |
author_sort | Dorileo, Maura Cristiane Gonçales Orçati |
collection | PubMed |
description | OBJECTIVES: This study evaluated the solubility, dimensional alteration, pH, electrical conductivity, and radiopacity of root perforation sealer materials. MATERIALS AND METHODS: For the pH test, the samples were immersed in distilled water for different periods of time. Then, the samples were retained in plastic recipients, and the electrical conductivity of the solution was measured. The solubility, dimensional alteration, and radiopacity properties were evaluated according to Specification No. 57 of the American National Standards Institute/American Dental Association (ANSI/ADA). Statistical analyses were carried out using analysis of variance (ANOVA) and Tukey's test at a significance level of 5%. When the sample distribution was not normal, a nonparametric ANOVA was performed with a Kruskal-Wallis test (α = 0.05). RESULTS: The results showed that white structural Portland cement (PC) had the highest solubility, while mineral trioxide aggregate (MTA)-based cements, ProRoot MTA (Dentsply-Tulsa Dental) and MTA BIO (Ângelus Ind. Prod.), had the lowest values. MTA BIO showed the lowest dimensional alteration values and white PC presented the highest values. No differences among the tested materials were observed in the the pH and electrical conductivity analyses. Only the MTA-based cements met the ANSI/ADA recommendations regarding radiopacity, overcoming the three steps of the aluminum step wedge. CONCLUSIONS: On the basis of these results, we concluded that the values of solubility and dimensional alteration of the materials were in accordance with the ANSI/ADA specifications. PCs did not fulfill the ANSI/ADA requirements regarding radiopacity. No differences were observed among the materials with respect to the pH and electrical conductivity analyses. |
format | Online Article Text |
id | pubmed-4125584 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Academy of Conservative Dentistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-41255842014-08-10 Comparative analysis of physicochemical properties of root perforation sealer materials Dorileo, Maura Cristiane Gonçales Orçati Pedro, Fábio Luis Miranda Bandeca, Matheus Coelho Guedes, Orlando Aguirre Villa, Ricardo Dalla Borges, Alvaro Henrique Restor Dent Endod Research Article OBJECTIVES: This study evaluated the solubility, dimensional alteration, pH, electrical conductivity, and radiopacity of root perforation sealer materials. MATERIALS AND METHODS: For the pH test, the samples were immersed in distilled water for different periods of time. Then, the samples were retained in plastic recipients, and the electrical conductivity of the solution was measured. The solubility, dimensional alteration, and radiopacity properties were evaluated according to Specification No. 57 of the American National Standards Institute/American Dental Association (ANSI/ADA). Statistical analyses were carried out using analysis of variance (ANOVA) and Tukey's test at a significance level of 5%. When the sample distribution was not normal, a nonparametric ANOVA was performed with a Kruskal-Wallis test (α = 0.05). RESULTS: The results showed that white structural Portland cement (PC) had the highest solubility, while mineral trioxide aggregate (MTA)-based cements, ProRoot MTA (Dentsply-Tulsa Dental) and MTA BIO (Ângelus Ind. Prod.), had the lowest values. MTA BIO showed the lowest dimensional alteration values and white PC presented the highest values. No differences among the tested materials were observed in the the pH and electrical conductivity analyses. Only the MTA-based cements met the ANSI/ADA recommendations regarding radiopacity, overcoming the three steps of the aluminum step wedge. CONCLUSIONS: On the basis of these results, we concluded that the values of solubility and dimensional alteration of the materials were in accordance with the ANSI/ADA specifications. PCs did not fulfill the ANSI/ADA requirements regarding radiopacity. No differences were observed among the materials with respect to the pH and electrical conductivity analyses. The Korean Academy of Conservative Dentistry 2014-08 2014-06-30 /pmc/articles/PMC4125584/ /pubmed/25110644 http://dx.doi.org/10.5395/rde.2014.39.3.201 Text en ©Copyights 2014. The Korean Academy of Conservative Dentistry. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Dorileo, Maura Cristiane Gonçales Orçati Pedro, Fábio Luis Miranda Bandeca, Matheus Coelho Guedes, Orlando Aguirre Villa, Ricardo Dalla Borges, Alvaro Henrique Comparative analysis of physicochemical properties of root perforation sealer materials |
title | Comparative analysis of physicochemical properties of root perforation sealer materials |
title_full | Comparative analysis of physicochemical properties of root perforation sealer materials |
title_fullStr | Comparative analysis of physicochemical properties of root perforation sealer materials |
title_full_unstemmed | Comparative analysis of physicochemical properties of root perforation sealer materials |
title_short | Comparative analysis of physicochemical properties of root perforation sealer materials |
title_sort | comparative analysis of physicochemical properties of root perforation sealer materials |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4125584/ https://www.ncbi.nlm.nih.gov/pubmed/25110644 http://dx.doi.org/10.5395/rde.2014.39.3.201 |
work_keys_str_mv | AT dorileomauracristianegoncalesorcati comparativeanalysisofphysicochemicalpropertiesofrootperforationsealermaterials AT pedrofabioluismiranda comparativeanalysisofphysicochemicalpropertiesofrootperforationsealermaterials AT bandecamatheuscoelho comparativeanalysisofphysicochemicalpropertiesofrootperforationsealermaterials AT guedesorlandoaguirre comparativeanalysisofphysicochemicalpropertiesofrootperforationsealermaterials AT villaricardodalla comparativeanalysisofphysicochemicalpropertiesofrootperforationsealermaterials AT borgesalvarohenrique comparativeanalysisofphysicochemicalpropertiesofrootperforationsealermaterials |