Cargando…

Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants

Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1:...

Descripción completa

Detalles Bibliográficos
Autores principales: Estelita, Sérgio, Janson, Guilherme, Chiqueto, Kelly, Ferreira, Eduardo Silveira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4127219/
https://www.ncbi.nlm.nih.gov/pubmed/25136368
http://dx.doi.org/10.1155/2014/424923
_version_ 1782329999749021696
author Estelita, Sérgio
Janson, Guilherme
Chiqueto, Kelly
Ferreira, Eduardo Silveira
author_facet Estelita, Sérgio
Janson, Guilherme
Chiqueto, Kelly
Ferreira, Eduardo Silveira
author_sort Estelita, Sérgio
collection PubMed
description Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 followed by sonication for cleaning before and after sandblasting (Al(2)O(3)-90 µ) and autoclave sterilization. G2 and G3 mini-implants were weighed after recycling process to evaluate weight loss (W). All the screws were broken to determine the fracture torque (FT). The influence of recycling process on FT and W was evaluated by ANOVA, Mann-Whitney, and multiple linear regression analysis. Results. FT was not influenced by recycling protocols even when sandblasting was added. Sandblasting caused weight loss due to abrasive mechanical stripping of screw surface. Screw diameter was the only variable that affected FT. Conclusions. Torsional strengths of screws that underwent the recycling protocols were not changed. Thus, screw diameter choice can be a more critical step to avoid screw fracture than recycling decision.
format Online
Article
Text
id pubmed-4127219
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41272192014-08-18 Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants Estelita, Sérgio Janson, Guilherme Chiqueto, Kelly Ferreira, Eduardo Silveira Int J Dent Research Article Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 followed by sonication for cleaning before and after sandblasting (Al(2)O(3)-90 µ) and autoclave sterilization. G2 and G3 mini-implants were weighed after recycling process to evaluate weight loss (W). All the screws were broken to determine the fracture torque (FT). The influence of recycling process on FT and W was evaluated by ANOVA, Mann-Whitney, and multiple linear regression analysis. Results. FT was not influenced by recycling protocols even when sandblasting was added. Sandblasting caused weight loss due to abrasive mechanical stripping of screw surface. Screw diameter was the only variable that affected FT. Conclusions. Torsional strengths of screws that underwent the recycling protocols were not changed. Thus, screw diameter choice can be a more critical step to avoid screw fracture than recycling decision. Hindawi Publishing Corporation 2014 2014-07-17 /pmc/articles/PMC4127219/ /pubmed/25136368 http://dx.doi.org/10.1155/2014/424923 Text en Copyright © 2014 Sérgio Estelita et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Estelita, Sérgio
Janson, Guilherme
Chiqueto, Kelly
Ferreira, Eduardo Silveira
Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants
title Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants
title_full Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants
title_fullStr Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants
title_full_unstemmed Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants
title_short Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants
title_sort effect of recycling protocol on mechanical strength of used mini-implants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4127219/
https://www.ncbi.nlm.nih.gov/pubmed/25136368
http://dx.doi.org/10.1155/2014/424923
work_keys_str_mv AT estelitasergio effectofrecyclingprotocolonmechanicalstrengthofusedminiimplants
AT jansonguilherme effectofrecyclingprotocolonmechanicalstrengthofusedminiimplants
AT chiquetokelly effectofrecyclingprotocolonmechanicalstrengthofusedminiimplants
AT ferreiraeduardosilveira effectofrecyclingprotocolonmechanicalstrengthofusedminiimplants