The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry
OBJECTIVES: To explore the effects of computed tomography (CT) image characteristics and B-spline knot spacing (BKS) on the spatial accuracy of a B-spline deformable image registration (DIR) in the head-and-neck geometry. METHODS: The effect of image feature content, image contrast, noise, and BKS o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4128373/ https://www.ncbi.nlm.nih.gov/pubmed/25074293 http://dx.doi.org/10.1186/1748-717X-9-169 |
_version_ | 1782330121854648320 |
---|---|
author | Brouwer, Charlotte L Kierkels, Roel GJ van ’t Veld, Aart A Sijtsema, Nanna M Meertens, Harm |
author_facet | Brouwer, Charlotte L Kierkels, Roel GJ van ’t Veld, Aart A Sijtsema, Nanna M Meertens, Harm |
author_sort | Brouwer, Charlotte L |
collection | PubMed |
description | OBJECTIVES: To explore the effects of computed tomography (CT) image characteristics and B-spline knot spacing (BKS) on the spatial accuracy of a B-spline deformable image registration (DIR) in the head-and-neck geometry. METHODS: The effect of image feature content, image contrast, noise, and BKS on the spatial accuracy of a B-spline DIR was studied. Phantom images were created with varying feature content and varying contrast-to-noise ratio (CNR), and deformed using a known smooth B-spline deformation. Subsequently, the deformed images were repeatedly registered with the original images using different BKSs. The quality of the DIR was expressed as the mean residual displacement (MRD) between the known imposed deformation and the result of the B-spline DIR. Finally, for three patients, head-and-neck planning CT scans were deformed with a realistic deformation field derived from a rescan CT of the same patient, resulting in a simulated deformed image and an a-priori known deformation field. Hence, a B-spline DIR was performed between the simulated image and the planning CT at different BKSs. Similar to the phantom cases, the DIR accuracy was evaluated by means of MRD. RESULTS: In total, 162 phantom registrations were performed with varying CNR and BKSs. MRD-values < 1.0 mm were observed with a BKS between 10–20 mm for image contrast ≥ ± 250 HU and noise < ± 200 HU. Decreasing the image feature content resulted in increased MRD-values at all BKSs. Using BKS = 15 mm for the three clinical cases resulted in an average MRD < 1.0 mm. CONCLUSIONS: For synthetically generated phantoms and three real CT cases the highest DIR accuracy was obtained for a BKS between 10–20 mm. The accuracy decreased with decreasing image feature content, decreasing image contrast, and higher noise levels. Our results indicate that DIR accuracy in clinical CT images (typical noise levels < ± 100 HU) will not be effected by the amount of image noise. |
format | Online Article Text |
id | pubmed-4128373 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-41283732014-08-12 The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry Brouwer, Charlotte L Kierkels, Roel GJ van ’t Veld, Aart A Sijtsema, Nanna M Meertens, Harm Radiat Oncol Research OBJECTIVES: To explore the effects of computed tomography (CT) image characteristics and B-spline knot spacing (BKS) on the spatial accuracy of a B-spline deformable image registration (DIR) in the head-and-neck geometry. METHODS: The effect of image feature content, image contrast, noise, and BKS on the spatial accuracy of a B-spline DIR was studied. Phantom images were created with varying feature content and varying contrast-to-noise ratio (CNR), and deformed using a known smooth B-spline deformation. Subsequently, the deformed images were repeatedly registered with the original images using different BKSs. The quality of the DIR was expressed as the mean residual displacement (MRD) between the known imposed deformation and the result of the B-spline DIR. Finally, for three patients, head-and-neck planning CT scans were deformed with a realistic deformation field derived from a rescan CT of the same patient, resulting in a simulated deformed image and an a-priori known deformation field. Hence, a B-spline DIR was performed between the simulated image and the planning CT at different BKSs. Similar to the phantom cases, the DIR accuracy was evaluated by means of MRD. RESULTS: In total, 162 phantom registrations were performed with varying CNR and BKSs. MRD-values < 1.0 mm were observed with a BKS between 10–20 mm for image contrast ≥ ± 250 HU and noise < ± 200 HU. Decreasing the image feature content resulted in increased MRD-values at all BKSs. Using BKS = 15 mm for the three clinical cases resulted in an average MRD < 1.0 mm. CONCLUSIONS: For synthetically generated phantoms and three real CT cases the highest DIR accuracy was obtained for a BKS between 10–20 mm. The accuracy decreased with decreasing image feature content, decreasing image contrast, and higher noise levels. Our results indicate that DIR accuracy in clinical CT images (typical noise levels < ± 100 HU) will not be effected by the amount of image noise. BioMed Central 2014-07-29 /pmc/articles/PMC4128373/ /pubmed/25074293 http://dx.doi.org/10.1186/1748-717X-9-169 Text en Copyright © 2014 Brouwer et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Brouwer, Charlotte L Kierkels, Roel GJ van ’t Veld, Aart A Sijtsema, Nanna M Meertens, Harm The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry |
title | The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry |
title_full | The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry |
title_fullStr | The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry |
title_full_unstemmed | The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry |
title_short | The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry |
title_sort | effects of computed tomography image characteristics and knot spacing on the spatial accuracy of b-spline deformable image registration in the head and neck geometry |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4128373/ https://www.ncbi.nlm.nih.gov/pubmed/25074293 http://dx.doi.org/10.1186/1748-717X-9-169 |
work_keys_str_mv | AT brouwercharlottel theeffectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT kierkelsroelgj theeffectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT vantveldaarta theeffectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT sijtsemanannam theeffectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT meertensharm theeffectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT brouwercharlottel effectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT kierkelsroelgj effectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT vantveldaarta effectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT sijtsemanannam effectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry AT meertensharm effectsofcomputedtomographyimagecharacteristicsandknotspacingonthespatialaccuracyofbsplinedeformableimageregistrationintheheadandneckgeometry |