Cargando…

Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both per...

Descripción completa

Detalles Bibliográficos
Autores principales: Kola, Mehmet, Duran, Hikmet, Turk, Adem, Mollamehmetoglu, Suleyman, Kalkisim, Ahmet, Erdol, Hidayet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4129666/
https://www.ncbi.nlm.nih.gov/pubmed/25136453
http://dx.doi.org/10.1155/2014/739652
_version_ 1782330260779433984
author Kola, Mehmet
Duran, Hikmet
Turk, Adem
Mollamehmetoglu, Suleyman
Kalkisim, Ahmet
Erdol, Hidayet
author_facet Kola, Mehmet
Duran, Hikmet
Turk, Adem
Mollamehmetoglu, Suleyman
Kalkisim, Ahmet
Erdol, Hidayet
author_sort Kola, Mehmet
collection PubMed
description Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ). Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC). Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2) and reproducibility (ICC, 0.916-0.999) were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2) and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all). Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.
format Online
Article
Text
id pubmed-4129666
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41296662014-08-18 Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents Kola, Mehmet Duran, Hikmet Turk, Adem Mollamehmetoglu, Suleyman Kalkisim, Ahmet Erdol, Hidayet J Ophthalmol Research Article Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ). Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC). Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2) and reproducibility (ICC, 0.916-0.999) were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2) and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all). Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned. Hindawi Publishing Corporation 2014 2014-07-22 /pmc/articles/PMC4129666/ /pubmed/25136453 http://dx.doi.org/10.1155/2014/739652 Text en Copyright © 2014 Mehmet Kola et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kola, Mehmet
Duran, Hikmet
Turk, Adem
Mollamehmetoglu, Suleyman
Kalkisim, Ahmet
Erdol, Hidayet
Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_full Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_fullStr Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_full_unstemmed Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_short Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents
title_sort evaluation of the repeatability and the reproducibility of al-scan measurements obtained by residents
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4129666/
https://www.ncbi.nlm.nih.gov/pubmed/25136453
http://dx.doi.org/10.1155/2014/739652
work_keys_str_mv AT kolamehmet evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT duranhikmet evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT turkadem evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT mollamehmetoglusuleyman evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT kalkisimahmet evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents
AT erdolhidayet evaluationoftherepeatabilityandthereproducibilityofalscanmeasurementsobtainedbyresidents