Cargando…

Evaluation of pars plana sclera fixation of posterior chamber intraocular lens

PURPOSE: The purpose of this study was to evaluate the clinical efficacy and safety of modified posterior chamber intraocular lens (PCIOL) implantation with transscleral fixation. DESIGN AND SETTING: This is a study, which is conducted at Department of Ophthalmology, Jinan Eye Hospital, Jinan Second...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Fangju, Liu, Wei, Shu, Xiangwei, Tan, Ruili, Ji, Qiang, Zhai, Xiangjuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4131319/
https://www.ncbi.nlm.nih.gov/pubmed/25005196
http://dx.doi.org/10.4103/0301-4738.126987
_version_ 1782330442738827264
author Han, Fangju
Liu, Wei
Shu, Xiangwei
Tan, Ruili
Ji, Qiang
Zhai, Xiangjuan
author_facet Han, Fangju
Liu, Wei
Shu, Xiangwei
Tan, Ruili
Ji, Qiang
Zhai, Xiangjuan
author_sort Han, Fangju
collection PubMed
description PURPOSE: The purpose of this study was to evaluate the clinical efficacy and safety of modified posterior chamber intraocular lens (PCIOL) implantation with transscleral fixation. DESIGN AND SETTING: This is a study, which is conducted at Department of Ophthalmology, Jinan Eye Hospital, Jinan Second People's Hospital. MATERIALS AND METHODS: A total of 82 patients who were scheduled for sutured PCIOL were divided randomly into modified and conventional groups. The former underwent PCIOL through pars plana fixation with knot buried and without scleral flap and the latter underwent transscleral fixation of PCIOL in the ciliary sulcus. The main outcome measures included operative time, postoperative visual acuity, and postoperative complications. RESULTS: The mean operative time of the modified group was 39.95 ± 5.87 min, which was significantly less than that of the conventional group (45.77 ± 5.21 min; P < 0.05). No difference was found in postoperative visual acuity between the two groups. There were no significant postoperative complications, including knot exposure, endophthalmitis, and retinal detachment in either group. The optical clamping of PCIOL was prone to occur in the conventional group. CONCLUSION: Modified sutured PCIOL implantation is a safe, effective, and feasible technique for the correction of aphakia in eyes without adequate posterior capsular support.
format Online
Article
Text
id pubmed-4131319
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-41313192014-08-14 Evaluation of pars plana sclera fixation of posterior chamber intraocular lens Han, Fangju Liu, Wei Shu, Xiangwei Tan, Ruili Ji, Qiang Zhai, Xiangjuan Indian J Ophthalmol Original Article PURPOSE: The purpose of this study was to evaluate the clinical efficacy and safety of modified posterior chamber intraocular lens (PCIOL) implantation with transscleral fixation. DESIGN AND SETTING: This is a study, which is conducted at Department of Ophthalmology, Jinan Eye Hospital, Jinan Second People's Hospital. MATERIALS AND METHODS: A total of 82 patients who were scheduled for sutured PCIOL were divided randomly into modified and conventional groups. The former underwent PCIOL through pars plana fixation with knot buried and without scleral flap and the latter underwent transscleral fixation of PCIOL in the ciliary sulcus. The main outcome measures included operative time, postoperative visual acuity, and postoperative complications. RESULTS: The mean operative time of the modified group was 39.95 ± 5.87 min, which was significantly less than that of the conventional group (45.77 ± 5.21 min; P < 0.05). No difference was found in postoperative visual acuity between the two groups. There were no significant postoperative complications, including knot exposure, endophthalmitis, and retinal detachment in either group. The optical clamping of PCIOL was prone to occur in the conventional group. CONCLUSION: Modified sutured PCIOL implantation is a safe, effective, and feasible technique for the correction of aphakia in eyes without adequate posterior capsular support. Medknow Publications & Media Pvt Ltd 2014-06 /pmc/articles/PMC4131319/ /pubmed/25005196 http://dx.doi.org/10.4103/0301-4738.126987 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Han, Fangju
Liu, Wei
Shu, Xiangwei
Tan, Ruili
Ji, Qiang
Zhai, Xiangjuan
Evaluation of pars plana sclera fixation of posterior chamber intraocular lens
title Evaluation of pars plana sclera fixation of posterior chamber intraocular lens
title_full Evaluation of pars plana sclera fixation of posterior chamber intraocular lens
title_fullStr Evaluation of pars plana sclera fixation of posterior chamber intraocular lens
title_full_unstemmed Evaluation of pars plana sclera fixation of posterior chamber intraocular lens
title_short Evaluation of pars plana sclera fixation of posterior chamber intraocular lens
title_sort evaluation of pars plana sclera fixation of posterior chamber intraocular lens
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4131319/
https://www.ncbi.nlm.nih.gov/pubmed/25005196
http://dx.doi.org/10.4103/0301-4738.126987
work_keys_str_mv AT hanfangju evaluationofparsplanasclerafixationofposteriorchamberintraocularlens
AT liuwei evaluationofparsplanasclerafixationofposteriorchamberintraocularlens
AT shuxiangwei evaluationofparsplanasclerafixationofposteriorchamberintraocularlens
AT tanruili evaluationofparsplanasclerafixationofposteriorchamberintraocularlens
AT jiqiang evaluationofparsplanasclerafixationofposteriorchamberintraocularlens
AT zhaixiangjuan evaluationofparsplanasclerafixationofposteriorchamberintraocularlens