Cargando…

A Shocking Complication of a Pneumothorax: Chest Tube-Induced Arrhythmias and Review of the Literature

We describe a patient with a recent chest tube insertion leading to atrial fibrillation with rapid ventricular rate that led to multiple inappropriate internal cardiac defibrillator (ICD) shocks. This is the first reported case of this occurring in a patient with an ICD leading to inappropriate shoc...

Descripción completa

Detalles Bibliográficos
Autores principales: Cardozo, Shaun, Belgrave, Kevin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4131458/
https://www.ncbi.nlm.nih.gov/pubmed/25147742
http://dx.doi.org/10.1155/2014/681572
_version_ 1782330461951885312
author Cardozo, Shaun
Belgrave, Kevin
author_facet Cardozo, Shaun
Belgrave, Kevin
author_sort Cardozo, Shaun
collection PubMed
description We describe a patient with a recent chest tube insertion leading to atrial fibrillation with rapid ventricular rate that led to multiple inappropriate internal cardiac defibrillator (ICD) shocks. This is the first reported case of this occurring in a patient with an ICD leading to inappropriate shocks. Our elderly patient with emphysema presented with a spontaneous pneumothorax and developed rapid atrial fibrillation following emergency tube thoracostomy. The patient had a single lead ICD and received multiple inappropriate shocks for the rapid ventricular rate in the therapy zone. Although medical treatment helped stabilize the patient, resolution of the atrial fibrillation occurred only after the chest tube was removed. In a patient with a chest tube or other intrathoracic catheters, maintaining a high index of suspicion that chest tube insertions can cause secondary life threatening cardiovascular complications needs to be considered. In such patients, removal of the device proves to be the most prudent treatment action.
format Online
Article
Text
id pubmed-4131458
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41314582014-08-21 A Shocking Complication of a Pneumothorax: Chest Tube-Induced Arrhythmias and Review of the Literature Cardozo, Shaun Belgrave, Kevin Case Rep Cardiol Case Report We describe a patient with a recent chest tube insertion leading to atrial fibrillation with rapid ventricular rate that led to multiple inappropriate internal cardiac defibrillator (ICD) shocks. This is the first reported case of this occurring in a patient with an ICD leading to inappropriate shocks. Our elderly patient with emphysema presented with a spontaneous pneumothorax and developed rapid atrial fibrillation following emergency tube thoracostomy. The patient had a single lead ICD and received multiple inappropriate shocks for the rapid ventricular rate in the therapy zone. Although medical treatment helped stabilize the patient, resolution of the atrial fibrillation occurred only after the chest tube was removed. In a patient with a chest tube or other intrathoracic catheters, maintaining a high index of suspicion that chest tube insertions can cause secondary life threatening cardiovascular complications needs to be considered. In such patients, removal of the device proves to be the most prudent treatment action. Hindawi Publishing Corporation 2014 2014-07-24 /pmc/articles/PMC4131458/ /pubmed/25147742 http://dx.doi.org/10.1155/2014/681572 Text en Copyright © 2014 S. Cardozo and K. Belgrave. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Cardozo, Shaun
Belgrave, Kevin
A Shocking Complication of a Pneumothorax: Chest Tube-Induced Arrhythmias and Review of the Literature
title A Shocking Complication of a Pneumothorax: Chest Tube-Induced Arrhythmias and Review of the Literature
title_full A Shocking Complication of a Pneumothorax: Chest Tube-Induced Arrhythmias and Review of the Literature
title_fullStr A Shocking Complication of a Pneumothorax: Chest Tube-Induced Arrhythmias and Review of the Literature
title_full_unstemmed A Shocking Complication of a Pneumothorax: Chest Tube-Induced Arrhythmias and Review of the Literature
title_short A Shocking Complication of a Pneumothorax: Chest Tube-Induced Arrhythmias and Review of the Literature
title_sort shocking complication of a pneumothorax: chest tube-induced arrhythmias and review of the literature
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4131458/
https://www.ncbi.nlm.nih.gov/pubmed/25147742
http://dx.doi.org/10.1155/2014/681572
work_keys_str_mv AT cardozoshaun ashockingcomplicationofapneumothoraxchesttubeinducedarrhythmiasandreviewoftheliterature
AT belgravekevin ashockingcomplicationofapneumothoraxchesttubeinducedarrhythmiasandreviewoftheliterature
AT cardozoshaun shockingcomplicationofapneumothoraxchesttubeinducedarrhythmiasandreviewoftheliterature
AT belgravekevin shockingcomplicationofapneumothoraxchesttubeinducedarrhythmiasandreviewoftheliterature