Cargando…

Use of Martius flap in the complex female urethral surgery

INTRODUCTION: Objectives were to evaluate safety and patient reported perception of the Martius fibroadipose flap for complex female urethra reconstruction. MATERIAL AND METHODS: Patients operated with a Martius flap were contacted again via telephone to rate their self–perception on cosmetic appear...

Descripción completa

Detalles Bibliográficos
Autores principales: Kasyan, George, Tupikina, Nataliya, Pushkar, Dmitry
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Polish Urological Association 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4132599/
https://www.ncbi.nlm.nih.gov/pubmed/25140241
http://dx.doi.org/10.5173/ceju.2014.02.art20
_version_ 1782330649855655936
author Kasyan, George
Tupikina, Nataliya
Pushkar, Dmitry
author_facet Kasyan, George
Tupikina, Nataliya
Pushkar, Dmitry
author_sort Kasyan, George
collection PubMed
description INTRODUCTION: Objectives were to evaluate safety and patient reported perception of the Martius fibroadipose flap for complex female urethra reconstruction. MATERIAL AND METHODS: Patients operated with a Martius flap were contacted again via telephone to rate their self–perception on cosmetic appearance, pain or numbness of the flap harvest site. RESULTS: 37 women (mean age of 46.8 yrs.) were operated with Martius flaps. Complications were limited to bleeding from the flap bed in 19% (7/37); hematomas – 5.4% (2/37); and lymphorrhea from the labial incision in 13.5% (5/37) and labial wound infection in 5.4% of cases (2/37). For self–perception 65% of patients (24/37) were phone interviewed (mean follow up – 54.2 months). Only 17% of women (4/24) complained to cosmetic problems. Two patients (8%) complained to a periodical mild pain. And 12.5% (3/24) of the women had decreased sensation or numbness at the labia. CONCLUSIONS: Martius flap is safe and it is not causing significant complications during female urethral reconstruction. However, an informed consent for decreased sensation and numbness at the flap harvesting area should be obtained.
format Online
Article
Text
id pubmed-4132599
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Polish Urological Association
record_format MEDLINE/PubMed
spelling pubmed-41325992014-08-19 Use of Martius flap in the complex female urethral surgery Kasyan, George Tupikina, Nataliya Pushkar, Dmitry Cent European J Urol Original Paper INTRODUCTION: Objectives were to evaluate safety and patient reported perception of the Martius fibroadipose flap for complex female urethra reconstruction. MATERIAL AND METHODS: Patients operated with a Martius flap were contacted again via telephone to rate their self–perception on cosmetic appearance, pain or numbness of the flap harvest site. RESULTS: 37 women (mean age of 46.8 yrs.) were operated with Martius flaps. Complications were limited to bleeding from the flap bed in 19% (7/37); hematomas – 5.4% (2/37); and lymphorrhea from the labial incision in 13.5% (5/37) and labial wound infection in 5.4% of cases (2/37). For self–perception 65% of patients (24/37) were phone interviewed (mean follow up – 54.2 months). Only 17% of women (4/24) complained to cosmetic problems. Two patients (8%) complained to a periodical mild pain. And 12.5% (3/24) of the women had decreased sensation or numbness at the labia. CONCLUSIONS: Martius flap is safe and it is not causing significant complications during female urethral reconstruction. However, an informed consent for decreased sensation and numbness at the flap harvesting area should be obtained. Polish Urological Association 2014-06-23 2014 /pmc/articles/PMC4132599/ /pubmed/25140241 http://dx.doi.org/10.5173/ceju.2014.02.art20 Text en Copyright by Polish Urological Association http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Kasyan, George
Tupikina, Nataliya
Pushkar, Dmitry
Use of Martius flap in the complex female urethral surgery
title Use of Martius flap in the complex female urethral surgery
title_full Use of Martius flap in the complex female urethral surgery
title_fullStr Use of Martius flap in the complex female urethral surgery
title_full_unstemmed Use of Martius flap in the complex female urethral surgery
title_short Use of Martius flap in the complex female urethral surgery
title_sort use of martius flap in the complex female urethral surgery
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4132599/
https://www.ncbi.nlm.nih.gov/pubmed/25140241
http://dx.doi.org/10.5173/ceju.2014.02.art20
work_keys_str_mv AT kasyangeorge useofmartiusflapinthecomplexfemaleurethralsurgery
AT tupikinanataliya useofmartiusflapinthecomplexfemaleurethralsurgery
AT pushkardmitry useofmartiusflapinthecomplexfemaleurethralsurgery