Cargando…

Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system

The fluorescein tear film break-up test is a common tear film stability test for dry eye diagnosis. This test requires applying fluorescein sodium drops to a tear film to observe the tear film break-up. However, this test is limited by using the fluorescein sodium drops, which can induce reflex tear...

Descripción completa

Detalles Bibliográficos
Autores principales: Su, Tai-Yuan, Chang, Shu-Wen, Yang, Chiao-Ju, Chiang, Huihua Kenny
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4132992/
https://www.ncbi.nlm.nih.gov/pubmed/25136489
http://dx.doi.org/10.1364/BOE.5.002614
_version_ 1782330697153773568
author Su, Tai-Yuan
Chang, Shu-Wen
Yang, Chiao-Ju
Chiang, Huihua Kenny
author_facet Su, Tai-Yuan
Chang, Shu-Wen
Yang, Chiao-Ju
Chiang, Huihua Kenny
author_sort Su, Tai-Yuan
collection PubMed
description The fluorescein tear film break-up test is a common tear film stability test for dry eye diagnosis. This test requires applying fluorescein sodium drops to a tear film to observe the tear film break-up. However, this test is limited by using the fluorescein sodium drops, which can induce reflex tearing and reduce the reliability of the diagnosis results. This paper proposes that tear film evaporation accelerates on the fluorescein tear film break-up area (FTBA), resulting in a lower temperature area (LTA) on the tear film. A dual modality system was established to capture the thermal and fluorescent image of fluorescein-stain tear films for 48 participants. Observations showed that the LTA and FTBA were highly correlated in their location (r = 0.82) and size (r = 0.91). This is first study to show that the FTBA and LTA are essentially the same region. This study demonstrated the feasibility of using the noncontact thermograph method to evaluate tear film stability without using a fluorescein sodium drop.
format Online
Article
Text
id pubmed-4132992
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-41329922014-08-18 Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system Su, Tai-Yuan Chang, Shu-Wen Yang, Chiao-Ju Chiang, Huihua Kenny Biomed Opt Express Article The fluorescein tear film break-up test is a common tear film stability test for dry eye diagnosis. This test requires applying fluorescein sodium drops to a tear film to observe the tear film break-up. However, this test is limited by using the fluorescein sodium drops, which can induce reflex tearing and reduce the reliability of the diagnosis results. This paper proposes that tear film evaporation accelerates on the fluorescein tear film break-up area (FTBA), resulting in a lower temperature area (LTA) on the tear film. A dual modality system was established to capture the thermal and fluorescent image of fluorescein-stain tear films for 48 participants. Observations showed that the LTA and FTBA were highly correlated in their location (r = 0.82) and size (r = 0.91). This is first study to show that the FTBA and LTA are essentially the same region. This study demonstrated the feasibility of using the noncontact thermograph method to evaluate tear film stability without using a fluorescein sodium drop. Optical Society of America 2014-07-14 /pmc/articles/PMC4132992/ /pubmed/25136489 http://dx.doi.org/10.1364/BOE.5.002614 Text en © 2014 Optical Society of America author-open
spellingShingle Article
Su, Tai-Yuan
Chang, Shu-Wen
Yang, Chiao-Ju
Chiang, Huihua Kenny
Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system
title Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system
title_full Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system
title_fullStr Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system
title_full_unstemmed Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system
title_short Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system
title_sort direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4132992/
https://www.ncbi.nlm.nih.gov/pubmed/25136489
http://dx.doi.org/10.1364/BOE.5.002614
work_keys_str_mv AT sutaiyuan directobservationandvalidationoffluoresceintearfilmbreakuppatternsbyusingadualthermalfluorescentimagingsystem
AT changshuwen directobservationandvalidationoffluoresceintearfilmbreakuppatternsbyusingadualthermalfluorescentimagingsystem
AT yangchiaoju directobservationandvalidationoffluoresceintearfilmbreakuppatternsbyusingadualthermalfluorescentimagingsystem
AT chianghuihuakenny directobservationandvalidationoffluoresceintearfilmbreakuppatternsbyusingadualthermalfluorescentimagingsystem