Cargando…
Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system
The fluorescein tear film break-up test is a common tear film stability test for dry eye diagnosis. This test requires applying fluorescein sodium drops to a tear film to observe the tear film break-up. However, this test is limited by using the fluorescein sodium drops, which can induce reflex tear...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4132992/ https://www.ncbi.nlm.nih.gov/pubmed/25136489 http://dx.doi.org/10.1364/BOE.5.002614 |
_version_ | 1782330697153773568 |
---|---|
author | Su, Tai-Yuan Chang, Shu-Wen Yang, Chiao-Ju Chiang, Huihua Kenny |
author_facet | Su, Tai-Yuan Chang, Shu-Wen Yang, Chiao-Ju Chiang, Huihua Kenny |
author_sort | Su, Tai-Yuan |
collection | PubMed |
description | The fluorescein tear film break-up test is a common tear film stability test for dry eye diagnosis. This test requires applying fluorescein sodium drops to a tear film to observe the tear film break-up. However, this test is limited by using the fluorescein sodium drops, which can induce reflex tearing and reduce the reliability of the diagnosis results. This paper proposes that tear film evaporation accelerates on the fluorescein tear film break-up area (FTBA), resulting in a lower temperature area (LTA) on the tear film. A dual modality system was established to capture the thermal and fluorescent image of fluorescein-stain tear films for 48 participants. Observations showed that the LTA and FTBA were highly correlated in their location (r = 0.82) and size (r = 0.91). This is first study to show that the FTBA and LTA are essentially the same region. This study demonstrated the feasibility of using the noncontact thermograph method to evaluate tear film stability without using a fluorescein sodium drop. |
format | Online Article Text |
id | pubmed-4132992 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-41329922014-08-18 Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system Su, Tai-Yuan Chang, Shu-Wen Yang, Chiao-Ju Chiang, Huihua Kenny Biomed Opt Express Article The fluorescein tear film break-up test is a common tear film stability test for dry eye diagnosis. This test requires applying fluorescein sodium drops to a tear film to observe the tear film break-up. However, this test is limited by using the fluorescein sodium drops, which can induce reflex tearing and reduce the reliability of the diagnosis results. This paper proposes that tear film evaporation accelerates on the fluorescein tear film break-up area (FTBA), resulting in a lower temperature area (LTA) on the tear film. A dual modality system was established to capture the thermal and fluorescent image of fluorescein-stain tear films for 48 participants. Observations showed that the LTA and FTBA were highly correlated in their location (r = 0.82) and size (r = 0.91). This is first study to show that the FTBA and LTA are essentially the same region. This study demonstrated the feasibility of using the noncontact thermograph method to evaluate tear film stability without using a fluorescein sodium drop. Optical Society of America 2014-07-14 /pmc/articles/PMC4132992/ /pubmed/25136489 http://dx.doi.org/10.1364/BOE.5.002614 Text en © 2014 Optical Society of America author-open |
spellingShingle | Article Su, Tai-Yuan Chang, Shu-Wen Yang, Chiao-Ju Chiang, Huihua Kenny Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system |
title | Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system |
title_full | Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system |
title_fullStr | Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system |
title_full_unstemmed | Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system |
title_short | Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system |
title_sort | direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4132992/ https://www.ncbi.nlm.nih.gov/pubmed/25136489 http://dx.doi.org/10.1364/BOE.5.002614 |
work_keys_str_mv | AT sutaiyuan directobservationandvalidationoffluoresceintearfilmbreakuppatternsbyusingadualthermalfluorescentimagingsystem AT changshuwen directobservationandvalidationoffluoresceintearfilmbreakuppatternsbyusingadualthermalfluorescentimagingsystem AT yangchiaoju directobservationandvalidationoffluoresceintearfilmbreakuppatternsbyusingadualthermalfluorescentimagingsystem AT chianghuihuakenny directobservationandvalidationoffluoresceintearfilmbreakuppatternsbyusingadualthermalfluorescentimagingsystem |