Cargando…

Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure

PURPOSE: To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure. MATERIALS AND METHODS: In this prospective study, 18 eyes of 10 patients (27.90±7.11 years, −5.64±2.45...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Yang, Zhao, Jing, Yao, Peijun, Miao, Huamao, Niu, Lingling, Wang, Xiaoying, Zhou, Xingtao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4133203/
https://www.ncbi.nlm.nih.gov/pubmed/25121508
http://dx.doi.org/10.1371/journal.pone.0103893
_version_ 1782330728754708480
author Shen, Yang
Zhao, Jing
Yao, Peijun
Miao, Huamao
Niu, Lingling
Wang, Xiaoying
Zhou, Xingtao
author_facet Shen, Yang
Zhao, Jing
Yao, Peijun
Miao, Huamao
Niu, Lingling
Wang, Xiaoying
Zhou, Xingtao
author_sort Shen, Yang
collection PubMed
description PURPOSE: To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure. MATERIALS AND METHODS: In this prospective study, 18 eyes of 10 patients (27.90±7.11 years, −5.64±2.45 diopters) scheduled for SMILE procedure were enrolled. Changes in the corneal deformation parameters, including deformation amplitude (DA), applanation time(AT1 and AT2), applanation length(AL1 and AL2), corneal velocity(CV1 and CV2), peak distance(P.Dist.), radius and intraocular pressure values were measured preoperatively, immediately after lenticule creation and subsequent to corneal lenticule extraction in all eyes with the Corvis Scheimpflug Technology (Corvis ST, OCULUS, Wetzlar, Germany). Repeated measures analysis of variance (ANOVA) with bonferroni-adjusted post hoc comparisons was performed to investigate changes following each step of the procedure. RESULTS: All surgical procedures were uneventful. A significant difference was detected among the three time points (pre-operation, post-lenticule creation and post lenticule extraction) for AT1 (P<0.001), AT2 (P = 0.001), DA(P<0.001), and IOP(P = 0.002). Bonferroni-adjusted post hoc comparisons indicated that there was no significant change in AT1, AT2, DA, or IOP after lenticule creation (post hoc P>0.05), but there was a significant change in these parameters following subsequent corneal lenticule extraction (post hoc P<0.01), when compared to values obtained pre-operatively. The scheimpflug camera of the Corvis ST demonstrated the intralamellar small gas bubbles formed from the vaporisation of tissue after lenticule creation and a gray zone was observed between the cap and the residual stromal bed after lenticule extraction. CONCLUSIONS: There is a significant change in corneal deformation parameters following SMILE procedure. The changes may be caused predominantly by stromal lenticule extraction, while lenticule creation with femtosecond laser may not have an obvious effect on corneal deformation properties.
format Online
Article
Text
id pubmed-4133203
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-41332032014-08-19 Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure Shen, Yang Zhao, Jing Yao, Peijun Miao, Huamao Niu, Lingling Wang, Xiaoying Zhou, Xingtao PLoS One Research Article PURPOSE: To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure. MATERIALS AND METHODS: In this prospective study, 18 eyes of 10 patients (27.90±7.11 years, −5.64±2.45 diopters) scheduled for SMILE procedure were enrolled. Changes in the corneal deformation parameters, including deformation amplitude (DA), applanation time(AT1 and AT2), applanation length(AL1 and AL2), corneal velocity(CV1 and CV2), peak distance(P.Dist.), radius and intraocular pressure values were measured preoperatively, immediately after lenticule creation and subsequent to corneal lenticule extraction in all eyes with the Corvis Scheimpflug Technology (Corvis ST, OCULUS, Wetzlar, Germany). Repeated measures analysis of variance (ANOVA) with bonferroni-adjusted post hoc comparisons was performed to investigate changes following each step of the procedure. RESULTS: All surgical procedures were uneventful. A significant difference was detected among the three time points (pre-operation, post-lenticule creation and post lenticule extraction) for AT1 (P<0.001), AT2 (P = 0.001), DA(P<0.001), and IOP(P = 0.002). Bonferroni-adjusted post hoc comparisons indicated that there was no significant change in AT1, AT2, DA, or IOP after lenticule creation (post hoc P>0.05), but there was a significant change in these parameters following subsequent corneal lenticule extraction (post hoc P<0.01), when compared to values obtained pre-operatively. The scheimpflug camera of the Corvis ST demonstrated the intralamellar small gas bubbles formed from the vaporisation of tissue after lenticule creation and a gray zone was observed between the cap and the residual stromal bed after lenticule extraction. CONCLUSIONS: There is a significant change in corneal deformation parameters following SMILE procedure. The changes may be caused predominantly by stromal lenticule extraction, while lenticule creation with femtosecond laser may not have an obvious effect on corneal deformation properties. Public Library of Science 2014-08-14 /pmc/articles/PMC4133203/ /pubmed/25121508 http://dx.doi.org/10.1371/journal.pone.0103893 Text en © 2014 Shen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Shen, Yang
Zhao, Jing
Yao, Peijun
Miao, Huamao
Niu, Lingling
Wang, Xiaoying
Zhou, Xingtao
Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure
title Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure
title_full Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure
title_fullStr Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure
title_full_unstemmed Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure
title_short Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure
title_sort changes in corneal deformation parameters after lenticule creation and extraction during small incision lenticule extraction (smile) procedure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4133203/
https://www.ncbi.nlm.nih.gov/pubmed/25121508
http://dx.doi.org/10.1371/journal.pone.0103893
work_keys_str_mv AT shenyang changesincornealdeformationparametersafterlenticulecreationandextractionduringsmallincisionlenticuleextractionsmileprocedure
AT zhaojing changesincornealdeformationparametersafterlenticulecreationandextractionduringsmallincisionlenticuleextractionsmileprocedure
AT yaopeijun changesincornealdeformationparametersafterlenticulecreationandextractionduringsmallincisionlenticuleextractionsmileprocedure
AT miaohuamao changesincornealdeformationparametersafterlenticulecreationandextractionduringsmallincisionlenticuleextractionsmileprocedure
AT niulingling changesincornealdeformationparametersafterlenticulecreationandextractionduringsmallincisionlenticuleextractionsmileprocedure
AT wangxiaoying changesincornealdeformationparametersafterlenticulecreationandextractionduringsmallincisionlenticuleextractionsmileprocedure
AT zhouxingtao changesincornealdeformationparametersafterlenticulecreationandextractionduringsmallincisionlenticuleextractionsmileprocedure