Estimation of the Iron Loss in Deep-Sea Permanent Magnet Motors considering Seawater Compressive Stress

Deep-sea permanent magnet motor equipped with fluid compensated pressure-tolerant system is compressed by the high pressure fluid both outside and inside. The induced stress distribution in stator core is significantly different from that in land type motor. Its effect on the magnetic properties of...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Yongxiang, Wei, Yanyu, Zou, Jibin, Li, Jianjun, Qi, Wenjuan, Li, Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4142183/
https://www.ncbi.nlm.nih.gov/pubmed/25177717
http://dx.doi.org/10.1155/2014/265816
_version_ 1782331741492477952
author Xu, Yongxiang
Wei, Yanyu
Zou, Jibin
Li, Jianjun
Qi, Wenjuan
Li, Yong
author_facet Xu, Yongxiang
Wei, Yanyu
Zou, Jibin
Li, Jianjun
Qi, Wenjuan
Li, Yong
author_sort Xu, Yongxiang
collection PubMed
description Deep-sea permanent magnet motor equipped with fluid compensated pressure-tolerant system is compressed by the high pressure fluid both outside and inside. The induced stress distribution in stator core is significantly different from that in land type motor. Its effect on the magnetic properties of stator core is important for deep-sea motor designers but seldom reported. In this paper, the stress distribution in stator core, regarding the seawater compressive stress, is calculated by 2D finite element method (FEM). The effect of compressive stress on magnetic properties of electrical steel sheet, that is, permeability, BH curves, and BW curves, is also measured. Then, based on the measured magnetic properties and calculated stress distribution, the stator iron loss is estimated by stress-electromagnetics-coupling FEM. At last the estimation is verified by experiment. Both the calculated and measured results show that stator iron loss increases obviously with the seawater compressive stress.
format Online
Article
Text
id pubmed-4142183
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41421832014-08-31 Estimation of the Iron Loss in Deep-Sea Permanent Magnet Motors considering Seawater Compressive Stress Xu, Yongxiang Wei, Yanyu Zou, Jibin Li, Jianjun Qi, Wenjuan Li, Yong ScientificWorldJournal Research Article Deep-sea permanent magnet motor equipped with fluid compensated pressure-tolerant system is compressed by the high pressure fluid both outside and inside. The induced stress distribution in stator core is significantly different from that in land type motor. Its effect on the magnetic properties of stator core is important for deep-sea motor designers but seldom reported. In this paper, the stress distribution in stator core, regarding the seawater compressive stress, is calculated by 2D finite element method (FEM). The effect of compressive stress on magnetic properties of electrical steel sheet, that is, permeability, BH curves, and BW curves, is also measured. Then, based on the measured magnetic properties and calculated stress distribution, the stator iron loss is estimated by stress-electromagnetics-coupling FEM. At last the estimation is verified by experiment. Both the calculated and measured results show that stator iron loss increases obviously with the seawater compressive stress. Hindawi Publishing Corporation 2014 2014-08-06 /pmc/articles/PMC4142183/ /pubmed/25177717 http://dx.doi.org/10.1155/2014/265816 Text en Copyright © 2014 Yongxiang Xu et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Xu, Yongxiang
Wei, Yanyu
Zou, Jibin
Li, Jianjun
Qi, Wenjuan
Li, Yong
Estimation of the Iron Loss in Deep-Sea Permanent Magnet Motors considering Seawater Compressive Stress
title Estimation of the Iron Loss in Deep-Sea Permanent Magnet Motors considering Seawater Compressive Stress
title_full Estimation of the Iron Loss in Deep-Sea Permanent Magnet Motors considering Seawater Compressive Stress
title_fullStr Estimation of the Iron Loss in Deep-Sea Permanent Magnet Motors considering Seawater Compressive Stress
title_full_unstemmed Estimation of the Iron Loss in Deep-Sea Permanent Magnet Motors considering Seawater Compressive Stress
title_short Estimation of the Iron Loss in Deep-Sea Permanent Magnet Motors considering Seawater Compressive Stress
title_sort estimation of the iron loss in deep-sea permanent magnet motors considering seawater compressive stress
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4142183/
https://www.ncbi.nlm.nih.gov/pubmed/25177717
http://dx.doi.org/10.1155/2014/265816
work_keys_str_mv AT xuyongxiang estimationoftheironlossindeepseapermanentmagnetmotorsconsideringseawatercompressivestress
AT weiyanyu estimationoftheironlossindeepseapermanentmagnetmotorsconsideringseawatercompressivestress
AT zoujibin estimationoftheironlossindeepseapermanentmagnetmotorsconsideringseawatercompressivestress
AT lijianjun estimationoftheironlossindeepseapermanentmagnetmotorsconsideringseawatercompressivestress
AT qiwenjuan estimationoftheironlossindeepseapermanentmagnetmotorsconsideringseawatercompressivestress
AT liyong estimationoftheironlossindeepseapermanentmagnetmotorsconsideringseawatercompressivestress