Cargando…

Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator

BACKGROUND: The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractur...

Descripción completa

Detalles Bibliográficos
Autores principales: Tafazal, Suhayl, Madan, Sanjeev S., Ali, Farhan, Padman, Manoj, Swift, Simone, Jones, Stanley, Fernandes, James A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4142886/
https://www.ncbi.nlm.nih.gov/pubmed/24748544
http://dx.doi.org/10.1007/s11832-014-0583-2
_version_ 1782331827403358208
author Tafazal, Suhayl
Madan, Sanjeev S.
Ali, Farhan
Padman, Manoj
Swift, Simone
Jones, Stanley
Fernandes, James A.
author_facet Tafazal, Suhayl
Madan, Sanjeev S.
Ali, Farhan
Padman, Manoj
Swift, Simone
Jones, Stanley
Fernandes, James A.
author_sort Tafazal, Suhayl
collection PubMed
description BACKGROUND: The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractures that required operative management. METHOD: A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, time duration in frame, healing time and complications of treatment. The minimum follow-up was 24 months. RESULTS: Ten patients were treated with ICF between 2000 and 2005, while 15 patients have been treated with TSF since 2005. Two of the 10 treated with ICF and 5 of the 15 treated with TSF were open fractures. All patients went on to achieve complete union. Mean duration in the frame was 12.7 weeks for ICF and 14.8 weeks for the TSF group. Two patients in the TSF group had delayed union and required additional procedures including adjustment of fixator and bone grafting. There was one malunion in the TSF group that required osteotomy and reapplication of frame. There were seven and nine pin-site infections in the ICF and TSF groups, respectively, all of which responded to antibiotics. There were no refractures in either group. CONCLUSION: In an appropriate patient, both types of circular fixator are equally effective but have different characteristics, with TSF allowing for postoperative deformity correction. Of concern are the two cases of delayed union in the TSF group, all in patients with high-energy injuries. We feel another larger study is required to provide further clarity in this matter. LEVEL OF EVIDENCE: Level II—comparative study.
format Online
Article
Text
id pubmed-4142886
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-41428862014-08-29 Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator Tafazal, Suhayl Madan, Sanjeev S. Ali, Farhan Padman, Manoj Swift, Simone Jones, Stanley Fernandes, James A. J Child Orthop Original Clinical Article BACKGROUND: The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractures that required operative management. METHOD: A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, time duration in frame, healing time and complications of treatment. The minimum follow-up was 24 months. RESULTS: Ten patients were treated with ICF between 2000 and 2005, while 15 patients have been treated with TSF since 2005. Two of the 10 treated with ICF and 5 of the 15 treated with TSF were open fractures. All patients went on to achieve complete union. Mean duration in the frame was 12.7 weeks for ICF and 14.8 weeks for the TSF group. Two patients in the TSF group had delayed union and required additional procedures including adjustment of fixator and bone grafting. There was one malunion in the TSF group that required osteotomy and reapplication of frame. There were seven and nine pin-site infections in the ICF and TSF groups, respectively, all of which responded to antibiotics. There were no refractures in either group. CONCLUSION: In an appropriate patient, both types of circular fixator are equally effective but have different characteristics, with TSF allowing for postoperative deformity correction. Of concern are the two cases of delayed union in the TSF group, all in patients with high-energy injuries. We feel another larger study is required to provide further clarity in this matter. LEVEL OF EVIDENCE: Level II—comparative study. Springer Berlin Heidelberg 2014-04-19 2014-05 /pmc/articles/PMC4142886/ /pubmed/24748544 http://dx.doi.org/10.1007/s11832-014-0583-2 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Clinical Article
Tafazal, Suhayl
Madan, Sanjeev S.
Ali, Farhan
Padman, Manoj
Swift, Simone
Jones, Stanley
Fernandes, James A.
Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator
title Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator
title_full Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator
title_fullStr Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator
title_full_unstemmed Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator
title_short Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator
title_sort management of paediatric tibial fractures using two types of circular external fixator: taylor spatial frame and ilizarov circular fixator
topic Original Clinical Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4142886/
https://www.ncbi.nlm.nih.gov/pubmed/24748544
http://dx.doi.org/10.1007/s11832-014-0583-2
work_keys_str_mv AT tafazalsuhayl managementofpaediatrictibialfracturesusingtwotypesofcircularexternalfixatortaylorspatialframeandilizarovcircularfixator
AT madansanjeevs managementofpaediatrictibialfracturesusingtwotypesofcircularexternalfixatortaylorspatialframeandilizarovcircularfixator
AT alifarhan managementofpaediatrictibialfracturesusingtwotypesofcircularexternalfixatortaylorspatialframeandilizarovcircularfixator
AT padmanmanoj managementofpaediatrictibialfracturesusingtwotypesofcircularexternalfixatortaylorspatialframeandilizarovcircularfixator
AT swiftsimone managementofpaediatrictibialfracturesusingtwotypesofcircularexternalfixatortaylorspatialframeandilizarovcircularfixator
AT jonesstanley managementofpaediatrictibialfracturesusingtwotypesofcircularexternalfixatortaylorspatialframeandilizarovcircularfixator
AT fernandesjamesa managementofpaediatrictibialfracturesusingtwotypesofcircularexternalfixatortaylorspatialframeandilizarovcircularfixator