Cargando…

Habituation to Experimentally Induced Electrical Pain during Voluntary-Breathing Controlled Electrical Stimulation (BreEStim)

OBJECTIVE: Painful peripheral electrical stimulation to acupuncture points was found to cause sensitization if delivered randomly (EStim), but induced habituation if triggered by voluntary breathing (BreEStim). The objective was to systematically compare the effectiveness of BreEStim and EStim and t...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Shengai, Hu, Tracy, Beran, Maria A., Li, Sheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4143193/
https://www.ncbi.nlm.nih.gov/pubmed/25153077
http://dx.doi.org/10.1371/journal.pone.0104729
_version_ 1782331861660336128
author Li, Shengai
Hu, Tracy
Beran, Maria A.
Li, Sheng
author_facet Li, Shengai
Hu, Tracy
Beran, Maria A.
Li, Sheng
author_sort Li, Shengai
collection PubMed
description OBJECTIVE: Painful peripheral electrical stimulation to acupuncture points was found to cause sensitization if delivered randomly (EStim), but induced habituation if triggered by voluntary breathing (BreEStim). The objective was to systematically compare the effectiveness of BreEStim and EStim and to investigate the possible mechanisms mediating the habituation effect of BreEStim. METHODS: Eleven pain-free, healthy subjects (6 males, 5 females) participated in the study. Each subject received the BreEStim and EStim treatments in a random order at least three days apart. Both treatments consisted of 120 painful but tolerable stimuli to the ulnar nerve at the elbow on the dominant arm. BreEStim was triggered by voluntary breathing while EStim was delivered randomly. Electrical sensation threshold (EST) and electrical pain threshold (EPT) were measured from the thenar and hypothenar eminences on both hands at pre-intervention and 10-minutes post-intervention. RESULTS: There was no difference in the pre-intervention baseline measurement of EST and EPT between BreEStim and EStim. BreEStim increased EPT in all tested sites on both hands, while EStim increased EPT in the dominant hypothenar eminence distal to the stimulating site and had no effect on EPT in other sites. There was no difference in the intensity of electrical stimulation between EStim and BreEStim. CONCLUSION: Our findings support the important role human voluntary breathing plays in the systemic habituation effect of BreEStim to peripheral painful electrical stimulation.
format Online
Article
Text
id pubmed-4143193
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-41431932014-08-27 Habituation to Experimentally Induced Electrical Pain during Voluntary-Breathing Controlled Electrical Stimulation (BreEStim) Li, Shengai Hu, Tracy Beran, Maria A. Li, Sheng PLoS One Research Article OBJECTIVE: Painful peripheral electrical stimulation to acupuncture points was found to cause sensitization if delivered randomly (EStim), but induced habituation if triggered by voluntary breathing (BreEStim). The objective was to systematically compare the effectiveness of BreEStim and EStim and to investigate the possible mechanisms mediating the habituation effect of BreEStim. METHODS: Eleven pain-free, healthy subjects (6 males, 5 females) participated in the study. Each subject received the BreEStim and EStim treatments in a random order at least three days apart. Both treatments consisted of 120 painful but tolerable stimuli to the ulnar nerve at the elbow on the dominant arm. BreEStim was triggered by voluntary breathing while EStim was delivered randomly. Electrical sensation threshold (EST) and electrical pain threshold (EPT) were measured from the thenar and hypothenar eminences on both hands at pre-intervention and 10-minutes post-intervention. RESULTS: There was no difference in the pre-intervention baseline measurement of EST and EPT between BreEStim and EStim. BreEStim increased EPT in all tested sites on both hands, while EStim increased EPT in the dominant hypothenar eminence distal to the stimulating site and had no effect on EPT in other sites. There was no difference in the intensity of electrical stimulation between EStim and BreEStim. CONCLUSION: Our findings support the important role human voluntary breathing plays in the systemic habituation effect of BreEStim to peripheral painful electrical stimulation. Public Library of Science 2014-08-25 /pmc/articles/PMC4143193/ /pubmed/25153077 http://dx.doi.org/10.1371/journal.pone.0104729 Text en © 2014 Li et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Li, Shengai
Hu, Tracy
Beran, Maria A.
Li, Sheng
Habituation to Experimentally Induced Electrical Pain during Voluntary-Breathing Controlled Electrical Stimulation (BreEStim)
title Habituation to Experimentally Induced Electrical Pain during Voluntary-Breathing Controlled Electrical Stimulation (BreEStim)
title_full Habituation to Experimentally Induced Electrical Pain during Voluntary-Breathing Controlled Electrical Stimulation (BreEStim)
title_fullStr Habituation to Experimentally Induced Electrical Pain during Voluntary-Breathing Controlled Electrical Stimulation (BreEStim)
title_full_unstemmed Habituation to Experimentally Induced Electrical Pain during Voluntary-Breathing Controlled Electrical Stimulation (BreEStim)
title_short Habituation to Experimentally Induced Electrical Pain during Voluntary-Breathing Controlled Electrical Stimulation (BreEStim)
title_sort habituation to experimentally induced electrical pain during voluntary-breathing controlled electrical stimulation (breestim)
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4143193/
https://www.ncbi.nlm.nih.gov/pubmed/25153077
http://dx.doi.org/10.1371/journal.pone.0104729
work_keys_str_mv AT lishengai habituationtoexperimentallyinducedelectricalpainduringvoluntarybreathingcontrolledelectricalstimulationbreestim
AT hutracy habituationtoexperimentallyinducedelectricalpainduringvoluntarybreathingcontrolledelectricalstimulationbreestim
AT beranmariaa habituationtoexperimentallyinducedelectricalpainduringvoluntarybreathingcontrolledelectricalstimulationbreestim
AT lisheng habituationtoexperimentallyinducedelectricalpainduringvoluntarybreathingcontrolledelectricalstimulationbreestim