Cargando…

Parameter Choice Matters: Validating Probe Parameters for Use in Mixed-Solvent Simulations

[Image: see text] Probe mapping is a common approach for identifying potential binding sites in structure-based drug design; however, it typically relies on energy minimizations of probes in the gas phase and a static protein structure. The mixed-solvent molecular dynamics (MixMD) approach was recen...

Descripción completa

Detalles Bibliográficos
Autores principales: Lexa, Katrina W., Goh, Garrett B., Carlson, Heather A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4144759/
https://www.ncbi.nlm.nih.gov/pubmed/25058662
http://dx.doi.org/10.1021/ci400741u
_version_ 1782332073102540800
author Lexa, Katrina W.
Goh, Garrett B.
Carlson, Heather A.
author_facet Lexa, Katrina W.
Goh, Garrett B.
Carlson, Heather A.
author_sort Lexa, Katrina W.
collection PubMed
description [Image: see text] Probe mapping is a common approach for identifying potential binding sites in structure-based drug design; however, it typically relies on energy minimizations of probes in the gas phase and a static protein structure. The mixed-solvent molecular dynamics (MixMD) approach was recently developed to account for full protein flexibility and solvation effects in hot-spot mapping. Our first study used only acetonitrile as a probe, and here, we have augmented the set of functional group probes through careful testing and parameter validation. A diverse range of probes are needed in order to map complex binding interactions. A small variation in probe parameters can adversely effect mixed-solvent behavior, which we highlight with isopropanol. We tested 11 solvents to identify six with appropriate behavior in TIP3P water to use as organic probes in the MixMD method. In addition to acetonitrile and isopropanol, we have identified acetone, N-methylacetamide, imidazole, and pyrimidine. These probe solvents will enable MixMD studies to recover hydrogen-bonding sites, hydrophobic pockets, protein–protein interactions, and aromatic hotspots. Also, we show that ternary-solvent systems can be incorporated within a single simulation. Importantly, these binary and ternary solvents do not require artificial repulsion terms like other methods. Within merely 5 ns, layered solvent boxes become evenly mixed for soluble probes. We used radial distribution functions to evaluate solvent behavior, determine adequate mixing, and confirm the absence of phase separation. We recommend that radial distribution functions should be used to assess adequate sampling in all mixed-solvent techniques rather than the current practice of examining the solvent ratios at the edges of the solvent box.
format Online
Article
Text
id pubmed-4144759
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-41447592015-07-24 Parameter Choice Matters: Validating Probe Parameters for Use in Mixed-Solvent Simulations Lexa, Katrina W. Goh, Garrett B. Carlson, Heather A. J Chem Inf Model [Image: see text] Probe mapping is a common approach for identifying potential binding sites in structure-based drug design; however, it typically relies on energy minimizations of probes in the gas phase and a static protein structure. The mixed-solvent molecular dynamics (MixMD) approach was recently developed to account for full protein flexibility and solvation effects in hot-spot mapping. Our first study used only acetonitrile as a probe, and here, we have augmented the set of functional group probes through careful testing and parameter validation. A diverse range of probes are needed in order to map complex binding interactions. A small variation in probe parameters can adversely effect mixed-solvent behavior, which we highlight with isopropanol. We tested 11 solvents to identify six with appropriate behavior in TIP3P water to use as organic probes in the MixMD method. In addition to acetonitrile and isopropanol, we have identified acetone, N-methylacetamide, imidazole, and pyrimidine. These probe solvents will enable MixMD studies to recover hydrogen-bonding sites, hydrophobic pockets, protein–protein interactions, and aromatic hotspots. Also, we show that ternary-solvent systems can be incorporated within a single simulation. Importantly, these binary and ternary solvents do not require artificial repulsion terms like other methods. Within merely 5 ns, layered solvent boxes become evenly mixed for soluble probes. We used radial distribution functions to evaluate solvent behavior, determine adequate mixing, and confirm the absence of phase separation. We recommend that radial distribution functions should be used to assess adequate sampling in all mixed-solvent techniques rather than the current practice of examining the solvent ratios at the edges of the solvent box. American Chemical Society 2014-07-24 2014-08-25 /pmc/articles/PMC4144759/ /pubmed/25058662 http://dx.doi.org/10.1021/ci400741u Text en Copyright © 2014 American Chemical Society Terms of Use (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html)
spellingShingle Lexa, Katrina W.
Goh, Garrett B.
Carlson, Heather A.
Parameter Choice Matters: Validating Probe Parameters for Use in Mixed-Solvent Simulations
title Parameter Choice Matters: Validating Probe Parameters for Use in Mixed-Solvent Simulations
title_full Parameter Choice Matters: Validating Probe Parameters for Use in Mixed-Solvent Simulations
title_fullStr Parameter Choice Matters: Validating Probe Parameters for Use in Mixed-Solvent Simulations
title_full_unstemmed Parameter Choice Matters: Validating Probe Parameters for Use in Mixed-Solvent Simulations
title_short Parameter Choice Matters: Validating Probe Parameters for Use in Mixed-Solvent Simulations
title_sort parameter choice matters: validating probe parameters for use in mixed-solvent simulations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4144759/
https://www.ncbi.nlm.nih.gov/pubmed/25058662
http://dx.doi.org/10.1021/ci400741u
work_keys_str_mv AT lexakatrinaw parameterchoicemattersvalidatingprobeparametersforuseinmixedsolventsimulations
AT gohgarrettb parameterchoicemattersvalidatingprobeparametersforuseinmixedsolventsimulations
AT carlsonheathera parameterchoicemattersvalidatingprobeparametersforuseinmixedsolventsimulations