Cargando…
Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry
Fumonisin A-series (FAs) in a reference material of corn sample that was naturally contaminated with fumonisins was characterized using high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitap MS). Peaks for fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3), in addit...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4147598/ https://www.ncbi.nlm.nih.gov/pubmed/25153258 http://dx.doi.org/10.3390/toxins6082580 |
_version_ | 1782332480863338496 |
---|---|
author | Tamura, Masayoshi Mochizuki, Naoki Nagatomi, Yasushi Toriba, Akira Hayakawa, Kazuichi |
author_facet | Tamura, Masayoshi Mochizuki, Naoki Nagatomi, Yasushi Toriba, Akira Hayakawa, Kazuichi |
author_sort | Tamura, Masayoshi |
collection | PubMed |
description | Fumonisin A-series (FAs) in a reference material of corn sample that was naturally contaminated with fumonisins was characterized using high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitap MS). Peaks for fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3), in addition to three peaks corresponding to unknown compounds I, II, and III, were detected in the chromatogram for the corn sample. Fragment ion analysis for FB1, FB2, and FB3 showed that while the ions formed at m/z values of 200–800 were similar to those formed by the cleavage of the tricarballylic acids and the hydroxyl groups, the fragmentation patterns at m/z values of 50–200 varied depending on the hydroxyl group locations in the compounds. Fragment ion analysis of compounds I–III revealed structural similarities to FBs, only differing by an additional C(2)H(2)O in the unknown compounds. Using these results and by comparing the product ion mass spectra of compound I with fumonisin A1 (FA1) synthesized from FB1 standards, compounds I–III were hypothesized to be N-acetyl analogs of FBs: fumonisins A1 (FA1), A2 (FA2), and A3 (FA3). The method for determining concentrations was validated with FA1, FB1, FB2, and FB3 standards and applied to analyze the reference material. The FB1, FB2, and FB3 analytical levels were within acceptance limits and the amount of FA1 in the material was ~15% of FB1 amount at 4.2 mg/kg. |
format | Online Article Text |
id | pubmed-4147598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-41475982014-08-28 Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry Tamura, Masayoshi Mochizuki, Naoki Nagatomi, Yasushi Toriba, Akira Hayakawa, Kazuichi Toxins (Basel) Article Fumonisin A-series (FAs) in a reference material of corn sample that was naturally contaminated with fumonisins was characterized using high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitap MS). Peaks for fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3), in addition to three peaks corresponding to unknown compounds I, II, and III, were detected in the chromatogram for the corn sample. Fragment ion analysis for FB1, FB2, and FB3 showed that while the ions formed at m/z values of 200–800 were similar to those formed by the cleavage of the tricarballylic acids and the hydroxyl groups, the fragmentation patterns at m/z values of 50–200 varied depending on the hydroxyl group locations in the compounds. Fragment ion analysis of compounds I–III revealed structural similarities to FBs, only differing by an additional C(2)H(2)O in the unknown compounds. Using these results and by comparing the product ion mass spectra of compound I with fumonisin A1 (FA1) synthesized from FB1 standards, compounds I–III were hypothesized to be N-acetyl analogs of FBs: fumonisins A1 (FA1), A2 (FA2), and A3 (FA3). The method for determining concentrations was validated with FA1, FB1, FB2, and FB3 standards and applied to analyze the reference material. The FB1, FB2, and FB3 analytical levels were within acceptance limits and the amount of FA1 in the material was ~15% of FB1 amount at 4.2 mg/kg. MDPI 2014-08-21 /pmc/articles/PMC4147598/ /pubmed/25153258 http://dx.doi.org/10.3390/toxins6082580 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Tamura, Masayoshi Mochizuki, Naoki Nagatomi, Yasushi Toriba, Akira Hayakawa, Kazuichi Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry |
title | Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry |
title_full | Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry |
title_fullStr | Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry |
title_full_unstemmed | Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry |
title_short | Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry |
title_sort | characterization of fumonisin a-series by high-resolution liquid chromatography-orbitrap mass spectrometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4147598/ https://www.ncbi.nlm.nih.gov/pubmed/25153258 http://dx.doi.org/10.3390/toxins6082580 |
work_keys_str_mv | AT tamuramasayoshi characterizationoffumonisinaseriesbyhighresolutionliquidchromatographyorbitrapmassspectrometry AT mochizukinaoki characterizationoffumonisinaseriesbyhighresolutionliquidchromatographyorbitrapmassspectrometry AT nagatomiyasushi characterizationoffumonisinaseriesbyhighresolutionliquidchromatographyorbitrapmassspectrometry AT toribaakira characterizationoffumonisinaseriesbyhighresolutionliquidchromatographyorbitrapmassspectrometry AT hayakawakazuichi characterizationoffumonisinaseriesbyhighresolutionliquidchromatographyorbitrapmassspectrometry |