Cargando…

Stacking and Analysis of Melamine in Milk Products with Acetonitrile-Salt Stacking Technique in Capillary Electrophoresis

Melamine was measured in real milk products with capillary electrophoresis (CE) based on acetonitrile-salt stacking (ASS) method. Real milk samples were deproteinized with acetonitrile at a final concentration of 60% (v/v) and then injected hydrodynamically at 50 mBar for 40.0 s. The optimized buffe...

Descripción completa

Detalles Bibliográficos
Autores principales: Kong, Yu, Wei, Chong, Hou, Zhanwu, Wang, Zilong, Yuan, Jiaqiang, Yu, Jiang, Zhao, Yongxi, Tang, Yuhai, Gao, Meili
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4150491/
https://www.ncbi.nlm.nih.gov/pubmed/25197612
http://dx.doi.org/10.1155/2014/212697
_version_ 1782332906312564736
author Kong, Yu
Wei, Chong
Hou, Zhanwu
Wang, Zilong
Yuan, Jiaqiang
Yu, Jiang
Zhao, Yongxi
Tang, Yuhai
Gao, Meili
author_facet Kong, Yu
Wei, Chong
Hou, Zhanwu
Wang, Zilong
Yuan, Jiaqiang
Yu, Jiang
Zhao, Yongxi
Tang, Yuhai
Gao, Meili
author_sort Kong, Yu
collection PubMed
description Melamine was measured in real milk products with capillary electrophoresis (CE) based on acetonitrile-salt stacking (ASS) method. Real milk samples were deproteinized with acetonitrile at a final concentration of 60% (v/v) and then injected hydrodynamically at 50 mBar for 40.0 s. The optimized buffer contains 80.0 mmol/L pH 2.8 phosphates. Melamine could be detected within 20.0 min at +10 kV with a low limit of detection (LOD) of 0.03 μmol/L. Satisfactory reproducibility (inter- and intraday RSD% both for migration time and peak area was lower than 5.0%) and a wide linearity range of 0.05 μmol/L ~ 10.0 μmol/L were achieved. The proposed method was suitable for routine assay of MEL in real milk samples that was subjected to a simple treatment step.
format Online
Article
Text
id pubmed-4150491
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41504912014-09-07 Stacking and Analysis of Melamine in Milk Products with Acetonitrile-Salt Stacking Technique in Capillary Electrophoresis Kong, Yu Wei, Chong Hou, Zhanwu Wang, Zilong Yuan, Jiaqiang Yu, Jiang Zhao, Yongxi Tang, Yuhai Gao, Meili J Anal Methods Chem Research Article Melamine was measured in real milk products with capillary electrophoresis (CE) based on acetonitrile-salt stacking (ASS) method. Real milk samples were deproteinized with acetonitrile at a final concentration of 60% (v/v) and then injected hydrodynamically at 50 mBar for 40.0 s. The optimized buffer contains 80.0 mmol/L pH 2.8 phosphates. Melamine could be detected within 20.0 min at +10 kV with a low limit of detection (LOD) of 0.03 μmol/L. Satisfactory reproducibility (inter- and intraday RSD% both for migration time and peak area was lower than 5.0%) and a wide linearity range of 0.05 μmol/L ~ 10.0 μmol/L were achieved. The proposed method was suitable for routine assay of MEL in real milk samples that was subjected to a simple treatment step. Hindawi Publishing Corporation 2014 2014-08-18 /pmc/articles/PMC4150491/ /pubmed/25197612 http://dx.doi.org/10.1155/2014/212697 Text en Copyright © 2014 Yu Kong et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kong, Yu
Wei, Chong
Hou, Zhanwu
Wang, Zilong
Yuan, Jiaqiang
Yu, Jiang
Zhao, Yongxi
Tang, Yuhai
Gao, Meili
Stacking and Analysis of Melamine in Milk Products with Acetonitrile-Salt Stacking Technique in Capillary Electrophoresis
title Stacking and Analysis of Melamine in Milk Products with Acetonitrile-Salt Stacking Technique in Capillary Electrophoresis
title_full Stacking and Analysis of Melamine in Milk Products with Acetonitrile-Salt Stacking Technique in Capillary Electrophoresis
title_fullStr Stacking and Analysis of Melamine in Milk Products with Acetonitrile-Salt Stacking Technique in Capillary Electrophoresis
title_full_unstemmed Stacking and Analysis of Melamine in Milk Products with Acetonitrile-Salt Stacking Technique in Capillary Electrophoresis
title_short Stacking and Analysis of Melamine in Milk Products with Acetonitrile-Salt Stacking Technique in Capillary Electrophoresis
title_sort stacking and analysis of melamine in milk products with acetonitrile-salt stacking technique in capillary electrophoresis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4150491/
https://www.ncbi.nlm.nih.gov/pubmed/25197612
http://dx.doi.org/10.1155/2014/212697
work_keys_str_mv AT kongyu stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis
AT weichong stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis
AT houzhanwu stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis
AT wangzilong stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis
AT yuanjiaqiang stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis
AT yujiang stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis
AT zhaoyongxi stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis
AT tangyuhai stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis
AT gaomeili stackingandanalysisofmelamineinmilkproductswithacetonitrilesaltstackingtechniqueincapillaryelectrophoresis