Cargando…

Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model

BACKGROUND: In total knee arthroplasty (TKA), cement penetration between 3 and 5 mm beneath the tibial tray is required to prevent loosening of the tibia component. The objective of this study was to develop and validate a reliable in vivo measuring technique using CT imaging to assess cement distri...

Descripción completa

Detalles Bibliográficos
Autores principales: Verburg, Hennie, van de Ridder, Laurens C, Verhoeven, Vincent WJ, Pilot, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4150551/
https://www.ncbi.nlm.nih.gov/pubmed/25158996
http://dx.doi.org/10.1186/1471-2342-14-29
_version_ 1782332919725948928
author Verburg, Hennie
van de Ridder, Laurens C
Verhoeven, Vincent WJ
Pilot, Peter
author_facet Verburg, Hennie
van de Ridder, Laurens C
Verhoeven, Vincent WJ
Pilot, Peter
author_sort Verburg, Hennie
collection PubMed
description BACKGROUND: In total knee arthroplasty (TKA), cement penetration between 3 and 5 mm beneath the tibial tray is required to prevent loosening of the tibia component. The objective of this study was to develop and validate a reliable in vivo measuring technique using CT imaging to assess cement distribution and penetration depth in the total area underneath a tibia prosthesis. METHODS: We defined the radiodensity ranges for trabecular tibia bone, polymethylmethacrylate (PMMA) cement and cement-penetrated trabecular bone and measured the percentages of cement penetration at various depths after cementing two tibia prostheses onto redundant femoral heads. One prosthesis was subsequently removed to examine the influence of the metal tibia prostheses on the quality of the CT images. The percentages of cement penetration in the CT slices were compared with percentages measured with photographs of the corresponding transversal slices. RESULTS: Trabecular bone and cement-penetrated trabecular bone had no overlap in quantitative scale of radio-density. There was no significant difference in mean HU values when measuring with or without the tibia prosthesis. The percentages of measured cement-penetrated trabecular bone in the CT slices of the specimen were within the range of percentages that could be expected based on the measurements with the photographs (p = 0.04). CONCLUSIONS: CT scan images provide valid results in measuring the penetration and distribution of cement into trabecular bone underneath the tibia component of a TKA. Since the proposed method does not turn metal elements into artefacts, it enables clinicians to assess the width and density of the cement mantle in vivo and to compare the results of different cementing methods in TKA.
format Online
Article
Text
id pubmed-4150551
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-41505512014-09-02 Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model Verburg, Hennie van de Ridder, Laurens C Verhoeven, Vincent WJ Pilot, Peter BMC Med Imaging Research Article BACKGROUND: In total knee arthroplasty (TKA), cement penetration between 3 and 5 mm beneath the tibial tray is required to prevent loosening of the tibia component. The objective of this study was to develop and validate a reliable in vivo measuring technique using CT imaging to assess cement distribution and penetration depth in the total area underneath a tibia prosthesis. METHODS: We defined the radiodensity ranges for trabecular tibia bone, polymethylmethacrylate (PMMA) cement and cement-penetrated trabecular bone and measured the percentages of cement penetration at various depths after cementing two tibia prostheses onto redundant femoral heads. One prosthesis was subsequently removed to examine the influence of the metal tibia prostheses on the quality of the CT images. The percentages of cement penetration in the CT slices were compared with percentages measured with photographs of the corresponding transversal slices. RESULTS: Trabecular bone and cement-penetrated trabecular bone had no overlap in quantitative scale of radio-density. There was no significant difference in mean HU values when measuring with or without the tibia prosthesis. The percentages of measured cement-penetrated trabecular bone in the CT slices of the specimen were within the range of percentages that could be expected based on the measurements with the photographs (p = 0.04). CONCLUSIONS: CT scan images provide valid results in measuring the penetration and distribution of cement into trabecular bone underneath the tibia component of a TKA. Since the proposed method does not turn metal elements into artefacts, it enables clinicians to assess the width and density of the cement mantle in vivo and to compare the results of different cementing methods in TKA. BioMed Central 2014-08-27 /pmc/articles/PMC4150551/ /pubmed/25158996 http://dx.doi.org/10.1186/1471-2342-14-29 Text en Copyright © 2014 Verburg et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Verburg, Hennie
van de Ridder, Laurens C
Verhoeven, Vincent WJ
Pilot, Peter
Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model
title Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model
title_full Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model
title_fullStr Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model
title_full_unstemmed Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model
title_short Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model
title_sort validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4150551/
https://www.ncbi.nlm.nih.gov/pubmed/25158996
http://dx.doi.org/10.1186/1471-2342-14-29
work_keys_str_mv AT verburghennie validationofameasuringtechniquewithcomputedtomographyforcementpenetrationintotrabecularboneunderneaththetibialtrayintotalkneearthroplastyonacadavermodel
AT vanderidderlaurensc validationofameasuringtechniquewithcomputedtomographyforcementpenetrationintotrabecularboneunderneaththetibialtrayintotalkneearthroplastyonacadavermodel
AT verhoevenvincentwj validationofameasuringtechniquewithcomputedtomographyforcementpenetrationintotrabecularboneunderneaththetibialtrayintotalkneearthroplastyonacadavermodel
AT pilotpeter validationofameasuringtechniquewithcomputedtomographyforcementpenetrationintotrabecularboneunderneaththetibialtrayintotalkneearthroplastyonacadavermodel