Cargando…

Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations

The dosimetric accuracies of CATPhan 504 and CIRS 062 have been evaluated using the kV-CBCT of Varian TrueBeam linac and Eclipse TPS. The assessment was done using the kV-CBCT as a standalone tool for dosimetric calculations towards Adaptive replanning. Dosimetric calculations were made without alte...

Descripción completa

Detalles Bibliográficos
Autores principales: Annkah, James Kwame, Rosenberg, Ivan, Hindocha, Naina, Moinuddin, Syed Ali, Ricketts, Kate, Adeyemi, Abiodun, Royle, Gary
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4154180/
https://www.ncbi.nlm.nih.gov/pubmed/25190991
http://dx.doi.org/10.4103/0971-6203.139001
_version_ 1782333379867312128
author Annkah, James Kwame
Rosenberg, Ivan
Hindocha, Naina
Moinuddin, Syed Ali
Ricketts, Kate
Adeyemi, Abiodun
Royle, Gary
author_facet Annkah, James Kwame
Rosenberg, Ivan
Hindocha, Naina
Moinuddin, Syed Ali
Ricketts, Kate
Adeyemi, Abiodun
Royle, Gary
author_sort Annkah, James Kwame
collection PubMed
description The dosimetric accuracies of CATPhan 504 and CIRS 062 have been evaluated using the kV-CBCT of Varian TrueBeam linac and Eclipse TPS. The assessment was done using the kV-CBCT as a standalone tool for dosimetric calculations towards Adaptive replanning. Dosimetric calculations were made without altering the HU-ED curves of the planning computed tomography (CT) scanner that is used by the Eclipse TPS. All computations were done using the images and dataset from kV-CBCT while maintaining the HU-ED calibration curve of the planning CT (pCT), assuming pCT was used for the initial treatment plan. Results showed that the CIRS phantom produces doses within ±5% of the CT-based plan while CATPhan 504 produces a variation of ±14% of the CT-based plan.
format Online
Article
Text
id pubmed-4154180
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-41541802014-09-04 Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations Annkah, James Kwame Rosenberg, Ivan Hindocha, Naina Moinuddin, Syed Ali Ricketts, Kate Adeyemi, Abiodun Royle, Gary J Med Phys Original Article The dosimetric accuracies of CATPhan 504 and CIRS 062 have been evaluated using the kV-CBCT of Varian TrueBeam linac and Eclipse TPS. The assessment was done using the kV-CBCT as a standalone tool for dosimetric calculations towards Adaptive replanning. Dosimetric calculations were made without altering the HU-ED curves of the planning computed tomography (CT) scanner that is used by the Eclipse TPS. All computations were done using the images and dataset from kV-CBCT while maintaining the HU-ED calibration curve of the planning CT (pCT), assuming pCT was used for the initial treatment plan. Results showed that the CIRS phantom produces doses within ±5% of the CT-based plan while CATPhan 504 produces a variation of ±14% of the CT-based plan. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4154180/ /pubmed/25190991 http://dx.doi.org/10.4103/0971-6203.139001 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Annkah, James Kwame
Rosenberg, Ivan
Hindocha, Naina
Moinuddin, Syed Ali
Ricketts, Kate
Adeyemi, Abiodun
Royle, Gary
Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations
title Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations
title_full Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations
title_fullStr Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations
title_full_unstemmed Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations
title_short Assessment of the dosimetric accuracies of CATPhan 504 and CIRS 062 using kV-CBCT for performing direct calculations
title_sort assessment of the dosimetric accuracies of catphan 504 and cirs 062 using kv-cbct for performing direct calculations
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4154180/
https://www.ncbi.nlm.nih.gov/pubmed/25190991
http://dx.doi.org/10.4103/0971-6203.139001
work_keys_str_mv AT annkahjameskwame assessmentofthedosimetricaccuraciesofcatphan504andcirs062usingkvcbctforperformingdirectcalculations
AT rosenbergivan assessmentofthedosimetricaccuraciesofcatphan504andcirs062usingkvcbctforperformingdirectcalculations
AT hindochanaina assessmentofthedosimetricaccuraciesofcatphan504andcirs062usingkvcbctforperformingdirectcalculations
AT moinuddinsyedali assessmentofthedosimetricaccuraciesofcatphan504andcirs062usingkvcbctforperformingdirectcalculations
AT rickettskate assessmentofthedosimetricaccuraciesofcatphan504andcirs062usingkvcbctforperformingdirectcalculations
AT adeyemiabiodun assessmentofthedosimetricaccuraciesofcatphan504andcirs062usingkvcbctforperformingdirectcalculations
AT roylegary assessmentofthedosimetricaccuraciesofcatphan504andcirs062usingkvcbctforperformingdirectcalculations