Prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning

BACKGROUND: The combination of biliary stent with photodynamic and chemotherapy seemed to be a beneficial palliative treatment of unresectable cholangiocarcinoma. However, by intravenous delivery to the target tumor the distribution of the drug had its limitations and caused serious side effect on n...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Min-Hua, Liang, Po-Chin, Chang, Kai-Chun, Huang, Jian-Yuan, Chang, Yu-Ting, Chang, Fuh-Yu, Wong, Jau-Min, Lin, Feng-Huei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4155126/
https://www.ncbi.nlm.nih.gov/pubmed/25138739
http://dx.doi.org/10.1186/1475-925X-13-118
_version_ 1782333533400858624
author Chen, Min-Hua
Liang, Po-Chin
Chang, Kai-Chun
Huang, Jian-Yuan
Chang, Yu-Ting
Chang, Fuh-Yu
Wong, Jau-Min
Lin, Feng-Huei
author_facet Chen, Min-Hua
Liang, Po-Chin
Chang, Kai-Chun
Huang, Jian-Yuan
Chang, Yu-Ting
Chang, Fuh-Yu
Wong, Jau-Min
Lin, Feng-Huei
author_sort Chen, Min-Hua
collection PubMed
description BACKGROUND: The combination of biliary stent with photodynamic and chemotherapy seemed to be a beneficial palliative treatment of unresectable cholangiocarcinoma. However, by intravenous delivery to the target tumor the distribution of the drug had its limitations and caused serious side effect on non-target organs. Therefore, in this study, we are going to develop a localized eluting stent, named PDT-chemo stent, covered with gemcitabine (GEM) and hematoporphyrin (HP). METHODS: The prototype of PDT-chemo stent was made through electrospinning and electrospraying dual-processes with an electrical charge to cover the stent with a drug-storing membrane from polymer liquid. The design of prototype used PU as the material of the backing layer, and PCL/PEG blends in different molar ratio of 9:1 and of 1:4 were used in two drug-storing layers with GEM and HP loaded respectively. RESULTS: The optical microscopy revealed that the backing layer was formed in fine fibers from electrospinning, while drug-storing layers, attributed to the droplets from electrospraying process. The covered membrane, the morphology of which was observed by scanning electron microscopy (SEM), covered the stent surface homogeneously without crack appearances. The GEM had almost 100% of electrosprayed efficiency than 70% HP loaded on the covered membrane due to the different solubility of drug in PEG/PCL blends. Drug release study confirmed the two-phased drug release pattern by regulating in different molar ratio of PEG/PCL blends polymer. CONCLUSIONS: The result proves that the PDT-chemo stent is composed of a first burst-releasing phase from HP and a later slow-releasing phase from GEM eluting. This two-phase of drug eluting stent may provide a new prospect of localized and controlled release treatment for cholangiocarcinoma disease.
format Online
Article
Text
id pubmed-4155126
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-41551262014-09-06 Prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning Chen, Min-Hua Liang, Po-Chin Chang, Kai-Chun Huang, Jian-Yuan Chang, Yu-Ting Chang, Fuh-Yu Wong, Jau-Min Lin, Feng-Huei Biomed Eng Online Research BACKGROUND: The combination of biliary stent with photodynamic and chemotherapy seemed to be a beneficial palliative treatment of unresectable cholangiocarcinoma. However, by intravenous delivery to the target tumor the distribution of the drug had its limitations and caused serious side effect on non-target organs. Therefore, in this study, we are going to develop a localized eluting stent, named PDT-chemo stent, covered with gemcitabine (GEM) and hematoporphyrin (HP). METHODS: The prototype of PDT-chemo stent was made through electrospinning and electrospraying dual-processes with an electrical charge to cover the stent with a drug-storing membrane from polymer liquid. The design of prototype used PU as the material of the backing layer, and PCL/PEG blends in different molar ratio of 9:1 and of 1:4 were used in two drug-storing layers with GEM and HP loaded respectively. RESULTS: The optical microscopy revealed that the backing layer was formed in fine fibers from electrospinning, while drug-storing layers, attributed to the droplets from electrospraying process. The covered membrane, the morphology of which was observed by scanning electron microscopy (SEM), covered the stent surface homogeneously without crack appearances. The GEM had almost 100% of electrosprayed efficiency than 70% HP loaded on the covered membrane due to the different solubility of drug in PEG/PCL blends. Drug release study confirmed the two-phased drug release pattern by regulating in different molar ratio of PEG/PCL blends polymer. CONCLUSIONS: The result proves that the PDT-chemo stent is composed of a first burst-releasing phase from HP and a later slow-releasing phase from GEM eluting. This two-phase of drug eluting stent may provide a new prospect of localized and controlled release treatment for cholangiocarcinoma disease. BioMed Central 2014-08-19 /pmc/articles/PMC4155126/ /pubmed/25138739 http://dx.doi.org/10.1186/1475-925X-13-118 Text en © Chen et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Chen, Min-Hua
Liang, Po-Chin
Chang, Kai-Chun
Huang, Jian-Yuan
Chang, Yu-Ting
Chang, Fuh-Yu
Wong, Jau-Min
Lin, Feng-Huei
Prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning
title Prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning
title_full Prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning
title_fullStr Prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning
title_full_unstemmed Prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning
title_short Prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning
title_sort prototype of biliary drug-eluting stent with photodynamic and chemotherapy using electrospinning
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4155126/
https://www.ncbi.nlm.nih.gov/pubmed/25138739
http://dx.doi.org/10.1186/1475-925X-13-118
work_keys_str_mv AT chenminhua prototypeofbiliarydrugelutingstentwithphotodynamicandchemotherapyusingelectrospinning
AT liangpochin prototypeofbiliarydrugelutingstentwithphotodynamicandchemotherapyusingelectrospinning
AT changkaichun prototypeofbiliarydrugelutingstentwithphotodynamicandchemotherapyusingelectrospinning
AT huangjianyuan prototypeofbiliarydrugelutingstentwithphotodynamicandchemotherapyusingelectrospinning
AT changyuting prototypeofbiliarydrugelutingstentwithphotodynamicandchemotherapyusingelectrospinning
AT changfuhyu prototypeofbiliarydrugelutingstentwithphotodynamicandchemotherapyusingelectrospinning
AT wongjaumin prototypeofbiliarydrugelutingstentwithphotodynamicandchemotherapyusingelectrospinning
AT linfenghuei prototypeofbiliarydrugelutingstentwithphotodynamicandchemotherapyusingelectrospinning