Dual-Phase Cardiac Diffusion Tensor Imaging with Strain Correction
PURPOSE: In this work we present a dual-phase diffusion tensor imaging (DTI) technique that incorporates a correction scheme for the cardiac material strain, based on 3D myocardial tagging. METHODS: In vivo dual-phase cardiac DTI with a stimulated echo approach and 3D tagging was performed in 10 hea...
Autores principales: | Stoeck, Christian T., Kalinowska, Aleksandra, von Deuster, Constantin, Harmer, Jack, Chan, Rachel W., Niemann, Markus, Manka, Robert, Atkinson, David, Sosnovik, David E., Mekkaoui, Choukri, Kozerke, Sebastian |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4156436/ https://www.ncbi.nlm.nih.gov/pubmed/25191900 http://dx.doi.org/10.1371/journal.pone.0107159 |
Ejemplares similares
-
Second order motion compensated spin-echo diffusion tensor imaging of the human heart
por: Stoeck, Christian T, et al.
Publicado: (2015) -
Spin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart
por: von Deuster, Constantin, et al.
Publicado: (2015) -
High-resolution diffusion tensor imaging of the human kidneys using a free-breathing, multi-slice, targeted field of view approach
por: Chan, Rachel W, et al.
Publicado: (2014) -
Second order motion compensated spin echo cardiac diffusion tensor imaging on clinical MR systems
por: Stoeck, Christian T, et al.
Publicado: (2016) -
Myocardial Scar Delineation Using Diffusion Tensor Magnetic Resonance Tractography
por: Mekkaoui, Choukri, et al.
Publicado: (2018)