Cargando…
Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% aceto...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shaheed Beheshti University of Medical Sciences
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157019/ https://www.ncbi.nlm.nih.gov/pubmed/25237339 |
_version_ | 1782333813634891776 |
---|---|
author | Fan, Peng-Cheng Ren, Jun Ma, Hui-Ping Jing, Lin-Lin Ma, Jun Jia, Zheng-Ping |
author_facet | Fan, Peng-Cheng Ren, Jun Ma, Hui-Ping Jing, Lin-Lin Ma, Jun Jia, Zheng-Ping |
author_sort | Fan, Peng-Cheng |
collection | PubMed |
description | A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was approximately 7 min. The autosampler was set with an injection volume of 10 μL. The calibration curve was linear in the concentration range of 0.1~15.0 µg/mL. The coefficient of determination (r) was greater than 0.9998. This method has been fully validated and shown to be specific, accurate and precise. The method was simple, rapid and the sample preparation was minimal. It was successfully applied to the analysis of healthy volunteer |
format | Online Article Text |
id | pubmed-4157019 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Shaheed Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-41570192014-09-18 Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization Fan, Peng-Cheng Ren, Jun Ma, Hui-Ping Jing, Lin-Lin Ma, Jun Jia, Zheng-Ping Iran J Pharm Res Original Article A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was approximately 7 min. The autosampler was set with an injection volume of 10 μL. The calibration curve was linear in the concentration range of 0.1~15.0 µg/mL. The coefficient of determination (r) was greater than 0.9998. This method has been fully validated and shown to be specific, accurate and precise. The method was simple, rapid and the sample preparation was minimal. It was successfully applied to the analysis of healthy volunteer Shaheed Beheshti University of Medical Sciences 2014 /pmc/articles/PMC4157019/ /pubmed/25237339 Text en © 2014 by School of Pharmacy, Shaheed Beheshti University of Medical Sciences and Health Services |
spellingShingle | Original Article Fan, Peng-Cheng Ren, Jun Ma, Hui-Ping Jing, Lin-Lin Ma, Jun Jia, Zheng-Ping Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization |
title | Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization |
title_full | Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization |
title_fullStr | Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization |
title_full_unstemmed | Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization |
title_short | Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization |
title_sort | liquid chromatography tandem mass/mass spectrometry for the quantification of fudosteine in human serum without precolumn derivatization |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157019/ https://www.ncbi.nlm.nih.gov/pubmed/25237339 |
work_keys_str_mv | AT fanpengcheng liquidchromatographytandemmassmassspectrometryforthequantificationoffudosteineinhumanserumwithoutprecolumnderivatization AT renjun liquidchromatographytandemmassmassspectrometryforthequantificationoffudosteineinhumanserumwithoutprecolumnderivatization AT mahuiping liquidchromatographytandemmassmassspectrometryforthequantificationoffudosteineinhumanserumwithoutprecolumnderivatization AT jinglinlin liquidchromatographytandemmassmassspectrometryforthequantificationoffudosteineinhumanserumwithoutprecolumnderivatization AT majun liquidchromatographytandemmassmassspectrometryforthequantificationoffudosteineinhumanserumwithoutprecolumnderivatization AT jiazhengping liquidchromatographytandemmassmassspectrometryforthequantificationoffudosteineinhumanserumwithoutprecolumnderivatization |