Cargando…
A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study
AIM: The aim of this study is to evaluate the center of resistance of maxillary incisors during simultaneous intrusion and retraction. SUBJECTS AND METHODS: In this study, the following steps were employed namely, (1) Preprocessing - the creation of geometric model, mesh generation and boundary cond...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157280/ https://www.ncbi.nlm.nih.gov/pubmed/25210384 http://dx.doi.org/10.4103/0975-7406.137387 |
_version_ | 1782333851065909248 |
---|---|
author | Aruna, J. |
author_facet | Aruna, J. |
author_sort | Aruna, J. |
collection | PubMed |
description | AIM: The aim of this study is to evaluate the center of resistance of maxillary incisors during simultaneous intrusion and retraction. SUBJECTS AND METHODS: In this study, the following steps were employed namely, (1) Preprocessing - the creation of geometric model, mesh generation and boundary conditions. (2) Postprocessing - the tooth movement and determination of center of resistance. RESULTS: The center of the mid-sagittal plane approximately 6 mm apical and 4 mm posterior to a line perpendicular to the occlusal plane from the labial alveolar crest of the central incisor resistance for the maxillary four incisors was located within the. CONCLUSION: Finite element is a sound mechanical method of analysis as it was sufficient enough to provide insight into interactions between orthodontic forces, and dental tissues and reliability of this study. Further by using this study clinically, the center of resistance can be precisely located in single rooted tooth during orthodontic treatment. |
format | Online Article Text |
id | pubmed-4157280 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-41572802014-09-10 A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study Aruna, J. J Pharm Bioallied Sci Dental Science - Original Article AIM: The aim of this study is to evaluate the center of resistance of maxillary incisors during simultaneous intrusion and retraction. SUBJECTS AND METHODS: In this study, the following steps were employed namely, (1) Preprocessing - the creation of geometric model, mesh generation and boundary conditions. (2) Postprocessing - the tooth movement and determination of center of resistance. RESULTS: The center of the mid-sagittal plane approximately 6 mm apical and 4 mm posterior to a line perpendicular to the occlusal plane from the labial alveolar crest of the central incisor resistance for the maxillary four incisors was located within the. CONCLUSION: Finite element is a sound mechanical method of analysis as it was sufficient enough to provide insight into interactions between orthodontic forces, and dental tissues and reliability of this study. Further by using this study clinically, the center of resistance can be precisely located in single rooted tooth during orthodontic treatment. Medknow Publications & Media Pvt Ltd 2014-07 /pmc/articles/PMC4157280/ /pubmed/25210384 http://dx.doi.org/10.4103/0975-7406.137387 Text en Copyright: © Journal of Pharmacy and Bioallied Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Dental Science - Original Article Aruna, J. A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study |
title | A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study |
title_full | A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study |
title_fullStr | A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study |
title_full_unstemmed | A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study |
title_short | A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study |
title_sort | study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: a finite element study |
topic | Dental Science - Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157280/ https://www.ncbi.nlm.nih.gov/pubmed/25210384 http://dx.doi.org/10.4103/0975-7406.137387 |
work_keys_str_mv | AT arunaj astudyonevaluationofcenterofresistanceofmaxillaryfourincisorsduringsimultaneousintrusionandretractionafiniteelementstudy AT arunaj studyonevaluationofcenterofresistanceofmaxillaryfourincisorsduringsimultaneousintrusionandretractionafiniteelementstudy |