Cargando…

A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study

AIM: The aim of this study is to evaluate the center of resistance of maxillary incisors during simultaneous intrusion and retraction. SUBJECTS AND METHODS: In this study, the following steps were employed namely, (1) Preprocessing - the creation of geometric model, mesh generation and boundary cond...

Descripción completa

Detalles Bibliográficos
Autor principal: Aruna, J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157280/
https://www.ncbi.nlm.nih.gov/pubmed/25210384
http://dx.doi.org/10.4103/0975-7406.137387
_version_ 1782333851065909248
author Aruna, J.
author_facet Aruna, J.
author_sort Aruna, J.
collection PubMed
description AIM: The aim of this study is to evaluate the center of resistance of maxillary incisors during simultaneous intrusion and retraction. SUBJECTS AND METHODS: In this study, the following steps were employed namely, (1) Preprocessing - the creation of geometric model, mesh generation and boundary conditions. (2) Postprocessing - the tooth movement and determination of center of resistance. RESULTS: The center of the mid-sagittal plane approximately 6 mm apical and 4 mm posterior to a line perpendicular to the occlusal plane from the labial alveolar crest of the central incisor resistance for the maxillary four incisors was located within the. CONCLUSION: Finite element is a sound mechanical method of analysis as it was sufficient enough to provide insight into interactions between orthodontic forces, and dental tissues and reliability of this study. Further by using this study clinically, the center of resistance can be precisely located in single rooted tooth during orthodontic treatment.
format Online
Article
Text
id pubmed-4157280
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-41572802014-09-10 A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study Aruna, J. J Pharm Bioallied Sci Dental Science - Original Article AIM: The aim of this study is to evaluate the center of resistance of maxillary incisors during simultaneous intrusion and retraction. SUBJECTS AND METHODS: In this study, the following steps were employed namely, (1) Preprocessing - the creation of geometric model, mesh generation and boundary conditions. (2) Postprocessing - the tooth movement and determination of center of resistance. RESULTS: The center of the mid-sagittal plane approximately 6 mm apical and 4 mm posterior to a line perpendicular to the occlusal plane from the labial alveolar crest of the central incisor resistance for the maxillary four incisors was located within the. CONCLUSION: Finite element is a sound mechanical method of analysis as it was sufficient enough to provide insight into interactions between orthodontic forces, and dental tissues and reliability of this study. Further by using this study clinically, the center of resistance can be precisely located in single rooted tooth during orthodontic treatment. Medknow Publications & Media Pvt Ltd 2014-07 /pmc/articles/PMC4157280/ /pubmed/25210384 http://dx.doi.org/10.4103/0975-7406.137387 Text en Copyright: © Journal of Pharmacy and Bioallied Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Dental Science - Original Article
Aruna, J.
A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study
title A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study
title_full A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study
title_fullStr A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study
title_full_unstemmed A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study
title_short A study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: A finite element study
title_sort study on evaluation of center of resistance of maxillary four incisors during simultaneous intrusion and retraction: a finite element study
topic Dental Science - Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157280/
https://www.ncbi.nlm.nih.gov/pubmed/25210384
http://dx.doi.org/10.4103/0975-7406.137387
work_keys_str_mv AT arunaj astudyonevaluationofcenterofresistanceofmaxillaryfourincisorsduringsimultaneousintrusionandretractionafiniteelementstudy
AT arunaj studyonevaluationofcenterofresistanceofmaxillaryfourincisorsduringsimultaneousintrusionandretractionafiniteelementstudy