Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method
Previously there have been no methods for directly tracing the flow of cerebrospinal fluid (CSF) under physiological conditions, and the circulation of CSF has therefore been studied and visualized by injecting a radioactively labeled tracer or contrast medium visible in x-ray images. The newly deve...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Medical Schools
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157376/ https://www.ncbi.nlm.nih.gov/pubmed/25165048 http://dx.doi.org/10.3325/cmj.2014.55.337 |
_version_ | 1782333864522285056 |
---|---|
author | Yamada, Shinya |
author_facet | Yamada, Shinya |
author_sort | Yamada, Shinya |
collection | PubMed |
description | Previously there have been no methods for directly tracing the flow of cerebrospinal fluid (CSF) under physiological conditions, and the circulation of CSF has therefore been studied and visualized by injecting a radioactively labeled tracer or contrast medium visible in x-ray images. The newly developed Time-Spatial Inversion Pulse (Time-SLIP) method makes it possible to directly visualize the flow of CSF using magnetic resonance imaging (MRI), permitting CSF dynamics to be depicted in a certain time frame. The CSF dynamics visualized using Time-SLIP has been found to differ markedly from the classical CSF circulation theory described in medical textbooks. It can be said that research on CSF dynamics has advanced to the next stage with the use of this innovative imaging method. Obtaining a more accurate understanding of normal CSF physiology and pathophysiology should lead to improved diagnostic accuracy, permit the identification of new etiological factors in a variety of diseases, and promote the development of new therapeutic approaches. |
format | Online Article Text |
id | pubmed-4157376 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Croatian Medical Schools |
record_format | MEDLINE/PubMed |
spelling | pubmed-41573762014-09-08 Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method Yamada, Shinya Croat Med J Cerebrospinal Fluid Physiology and Movement Previously there have been no methods for directly tracing the flow of cerebrospinal fluid (CSF) under physiological conditions, and the circulation of CSF has therefore been studied and visualized by injecting a radioactively labeled tracer or contrast medium visible in x-ray images. The newly developed Time-Spatial Inversion Pulse (Time-SLIP) method makes it possible to directly visualize the flow of CSF using magnetic resonance imaging (MRI), permitting CSF dynamics to be depicted in a certain time frame. The CSF dynamics visualized using Time-SLIP has been found to differ markedly from the classical CSF circulation theory described in medical textbooks. It can be said that research on CSF dynamics has advanced to the next stage with the use of this innovative imaging method. Obtaining a more accurate understanding of normal CSF physiology and pathophysiology should lead to improved diagnostic accuracy, permit the identification of new etiological factors in a variety of diseases, and promote the development of new therapeutic approaches. Croatian Medical Schools 2014-08 /pmc/articles/PMC4157376/ /pubmed/25165048 http://dx.doi.org/10.3325/cmj.2014.55.337 Text en Copyright © 2014 by the Croatian Medical Journal. All rights reserved. http://creativecommons.org/licenses/by/2.5/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Cerebrospinal Fluid Physiology and Movement Yamada, Shinya Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method |
title | Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method |
title_full | Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method |
title_fullStr | Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method |
title_full_unstemmed | Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method |
title_short | Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method |
title_sort | cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging time-spatial inversion pulse method |
topic | Cerebrospinal Fluid Physiology and Movement |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157376/ https://www.ncbi.nlm.nih.gov/pubmed/25165048 http://dx.doi.org/10.3325/cmj.2014.55.337 |
work_keys_str_mv | AT yamadashinya cerebrospinalfluidphysiologyvisualizationofcerebrospinalfluiddynamicsusingthemagneticresonanceimagingtimespatialinversionpulsemethod |