Cargando…

Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method

Previously there have been no methods for directly tracing the flow of cerebrospinal fluid (CSF) under physiological conditions, and the circulation of CSF has therefore been studied and visualized by injecting a radioactively labeled tracer or contrast medium visible in x-ray images. The newly deve...

Descripción completa

Detalles Bibliográficos
Autor principal: Yamada, Shinya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Medical Schools 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157376/
https://www.ncbi.nlm.nih.gov/pubmed/25165048
http://dx.doi.org/10.3325/cmj.2014.55.337
_version_ 1782333864522285056
author Yamada, Shinya
author_facet Yamada, Shinya
author_sort Yamada, Shinya
collection PubMed
description Previously there have been no methods for directly tracing the flow of cerebrospinal fluid (CSF) under physiological conditions, and the circulation of CSF has therefore been studied and visualized by injecting a radioactively labeled tracer or contrast medium visible in x-ray images. The newly developed Time-Spatial Inversion Pulse (Time-SLIP) method makes it possible to directly visualize the flow of CSF using magnetic resonance imaging (MRI), permitting CSF dynamics to be depicted in a certain time frame. The CSF dynamics visualized using Time-SLIP has been found to differ markedly from the classical CSF circulation theory described in medical textbooks. It can be said that research on CSF dynamics has advanced to the next stage with the use of this innovative imaging method. Obtaining a more accurate understanding of normal CSF physiology and pathophysiology should lead to improved diagnostic accuracy, permit the identification of new etiological factors in a variety of diseases, and promote the development of new therapeutic approaches.
format Online
Article
Text
id pubmed-4157376
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Croatian Medical Schools
record_format MEDLINE/PubMed
spelling pubmed-41573762014-09-08 Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method Yamada, Shinya Croat Med J Cerebrospinal Fluid Physiology and Movement Previously there have been no methods for directly tracing the flow of cerebrospinal fluid (CSF) under physiological conditions, and the circulation of CSF has therefore been studied and visualized by injecting a radioactively labeled tracer or contrast medium visible in x-ray images. The newly developed Time-Spatial Inversion Pulse (Time-SLIP) method makes it possible to directly visualize the flow of CSF using magnetic resonance imaging (MRI), permitting CSF dynamics to be depicted in a certain time frame. The CSF dynamics visualized using Time-SLIP has been found to differ markedly from the classical CSF circulation theory described in medical textbooks. It can be said that research on CSF dynamics has advanced to the next stage with the use of this innovative imaging method. Obtaining a more accurate understanding of normal CSF physiology and pathophysiology should lead to improved diagnostic accuracy, permit the identification of new etiological factors in a variety of diseases, and promote the development of new therapeutic approaches. Croatian Medical Schools 2014-08 /pmc/articles/PMC4157376/ /pubmed/25165048 http://dx.doi.org/10.3325/cmj.2014.55.337 Text en Copyright © 2014 by the Croatian Medical Journal. All rights reserved. http://creativecommons.org/licenses/by/2.5/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cerebrospinal Fluid Physiology and Movement
Yamada, Shinya
Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method
title Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method
title_full Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method
title_fullStr Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method
title_full_unstemmed Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method
title_short Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method
title_sort cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging time-spatial inversion pulse method
topic Cerebrospinal Fluid Physiology and Movement
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4157376/
https://www.ncbi.nlm.nih.gov/pubmed/25165048
http://dx.doi.org/10.3325/cmj.2014.55.337
work_keys_str_mv AT yamadashinya cerebrospinalfluidphysiologyvisualizationofcerebrospinalfluiddynamicsusingthemagneticresonanceimagingtimespatialinversionpulsemethod