Cargando…

Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility

Electric Cell-substrate Impedance Sensing (ECIS) is an in vitro impedance measuring system to quantify the behavior of cells within adherent cell layers. To this end, cells are grown in special culture chambers on top of opposing, circular gold electrodes. A constant small alternating current is app...

Descripción completa

Detalles Bibliográficos
Autores principales: Szulcek, Robert, Bogaard, Harm Jan, van Nieuw Amerongen, Geerten P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MyJove Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4159052/
https://www.ncbi.nlm.nih.gov/pubmed/24747269
http://dx.doi.org/10.3791/51300
_version_ 1782334157298335744
author Szulcek, Robert
Bogaard, Harm Jan
van Nieuw Amerongen, Geerten P.
author_facet Szulcek, Robert
Bogaard, Harm Jan
van Nieuw Amerongen, Geerten P.
author_sort Szulcek, Robert
collection PubMed
description Electric Cell-substrate Impedance Sensing (ECIS) is an in vitro impedance measuring system to quantify the behavior of cells within adherent cell layers. To this end, cells are grown in special culture chambers on top of opposing, circular gold electrodes. A constant small alternating current is applied between the electrodes and the potential across is measured. The insulating properties of the cell membrane create a resistance towards the electrical current flow resulting in an increased electrical potential between the electrodes. Measuring cellular impedance in this manner allows the automated study of cell attachment, growth, morphology, function, and motility. Although the ECIS measurement itself is straightforward and easy to learn, the underlying theory is complex and selection of the right settings and correct analysis and interpretation of the data is not self-evident. Yet, a clear protocol describing the individual steps from the experimental design to preparation, realization, and analysis of the experiment is not available. In this article the basic measurement principle as well as possible applications, experimental considerations, advantages and limitations of the ECIS system are discussed. A guide is provided for the study of cell attachment, spreading and proliferation; quantification of cell behavior in a confluent layer, with regard to barrier function, cell motility, quality of cell-cell and cell-substrate adhesions; and quantification of wound healing and cellular responses to vasoactive stimuli. Representative results are discussed based on human microvascular (MVEC) and human umbilical vein endothelial cells (HUVEC), but are applicable to all adherent growing cells.
format Online
Article
Text
id pubmed-4159052
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MyJove Corporation
record_format MEDLINE/PubMed
spelling pubmed-41590522014-09-10 Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility Szulcek, Robert Bogaard, Harm Jan van Nieuw Amerongen, Geerten P. J Vis Exp Bioengineering Electric Cell-substrate Impedance Sensing (ECIS) is an in vitro impedance measuring system to quantify the behavior of cells within adherent cell layers. To this end, cells are grown in special culture chambers on top of opposing, circular gold electrodes. A constant small alternating current is applied between the electrodes and the potential across is measured. The insulating properties of the cell membrane create a resistance towards the electrical current flow resulting in an increased electrical potential between the electrodes. Measuring cellular impedance in this manner allows the automated study of cell attachment, growth, morphology, function, and motility. Although the ECIS measurement itself is straightforward and easy to learn, the underlying theory is complex and selection of the right settings and correct analysis and interpretation of the data is not self-evident. Yet, a clear protocol describing the individual steps from the experimental design to preparation, realization, and analysis of the experiment is not available. In this article the basic measurement principle as well as possible applications, experimental considerations, advantages and limitations of the ECIS system are discussed. A guide is provided for the study of cell attachment, spreading and proliferation; quantification of cell behavior in a confluent layer, with regard to barrier function, cell motility, quality of cell-cell and cell-substrate adhesions; and quantification of wound healing and cellular responses to vasoactive stimuli. Representative results are discussed based on human microvascular (MVEC) and human umbilical vein endothelial cells (HUVEC), but are applicable to all adherent growing cells. MyJove Corporation 2014-03-28 /pmc/articles/PMC4159052/ /pubmed/24747269 http://dx.doi.org/10.3791/51300 Text en Copyright © 2014, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Bioengineering
Szulcek, Robert
Bogaard, Harm Jan
van Nieuw Amerongen, Geerten P.
Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
title Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
title_full Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
title_fullStr Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
title_full_unstemmed Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
title_short Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
title_sort electric cell-substrate impedance sensing for the quantification of endothelial proliferation, barrier function, and motility
topic Bioengineering
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4159052/
https://www.ncbi.nlm.nih.gov/pubmed/24747269
http://dx.doi.org/10.3791/51300
work_keys_str_mv AT szulcekrobert electriccellsubstrateimpedancesensingforthequantificationofendothelialproliferationbarrierfunctionandmotility
AT bogaardharmjan electriccellsubstrateimpedancesensingforthequantificationofendothelialproliferationbarrierfunctionandmotility
AT vannieuwamerongengeertenp electriccellsubstrateimpedancesensingforthequantificationofendothelialproliferationbarrierfunctionandmotility