Cargando…

A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope

Objective: To compare hemodynamic stress response (HDSR) to ET intubation using Glidescope (GLS) and Flexible fiberoptic laryngoscope (FFB). Methods: This prospective randomized comparative study was conducted at King Khalid University Hospital, King Saud University, Riyadh, Saudi Arabia from June 2...

Descripción completa

Detalles Bibliográficos
Autor principal: Aqil, Mansoor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Professional Medical Publicaitons 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4163221/
https://www.ncbi.nlm.nih.gov/pubmed/25225515
http://dx.doi.org/10.12669/pjms.305.4788
_version_ 1782334762977853440
author Aqil, Mansoor
author_facet Aqil, Mansoor
author_sort Aqil, Mansoor
collection PubMed
description Objective: To compare hemodynamic stress response (HDSR) to ET intubation using Glidescope (GLS) and Flexible fiberoptic laryngoscope (FFB). Methods: This prospective randomized comparative study was conducted at King Khalid University Hospital, King Saud University, Riyadh, Saudi Arabia from June 2011 - November 2013. Eighty ASA 1 & 2 patients with normal airway undergoing elective surgical procedure requiring ET intubation were included in the study. Patients were randomly assigned in two groups GLS or FFB. General anesthesia was induced with propofol and fentanyl. Muscle relaxation was achieved with cisatracurium and ET intubation was performed using either GLS or FFB. Noninvasive hemodynamic data was recorded (HR, systolic, diastolic and mean blood pressure) as pre-induction, baseline and after ET intubation at one minute intervals for successive five minutes. End tidal Sevoflurane and CO2 at the time of intubation, need of external neck pressure, time to successful intubation and number of attempts were recorded; and rate pressure product was calculated. Results: Induction of anesthesia resulted in significant fall in blood pressure in both the groups. ET intubation resulted in similar rise of BP in both groups (for 3-4 minutes) from their baseline values; however the rise was not significantly different from their respective pre-induction values. Time to intubation was longer with FFB compared to GLS however, need for external neck manipulation was more with GLS. Conclusion: There was no difference in HDSR due to ET intubation using either GLS or FFB in healthy adult patients with normal airway. Rate pressure product remained within the acceptable range.
format Online
Article
Text
id pubmed-4163221
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Professional Medical Publicaitons
record_format MEDLINE/PubMed
spelling pubmed-41632212014-09-15 A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope Aqil, Mansoor Pak J Med Sci Original Article Objective: To compare hemodynamic stress response (HDSR) to ET intubation using Glidescope (GLS) and Flexible fiberoptic laryngoscope (FFB). Methods: This prospective randomized comparative study was conducted at King Khalid University Hospital, King Saud University, Riyadh, Saudi Arabia from June 2011 - November 2013. Eighty ASA 1 & 2 patients with normal airway undergoing elective surgical procedure requiring ET intubation were included in the study. Patients were randomly assigned in two groups GLS or FFB. General anesthesia was induced with propofol and fentanyl. Muscle relaxation was achieved with cisatracurium and ET intubation was performed using either GLS or FFB. Noninvasive hemodynamic data was recorded (HR, systolic, diastolic and mean blood pressure) as pre-induction, baseline and after ET intubation at one minute intervals for successive five minutes. End tidal Sevoflurane and CO2 at the time of intubation, need of external neck pressure, time to successful intubation and number of attempts were recorded; and rate pressure product was calculated. Results: Induction of anesthesia resulted in significant fall in blood pressure in both the groups. ET intubation resulted in similar rise of BP in both groups (for 3-4 minutes) from their baseline values; however the rise was not significantly different from their respective pre-induction values. Time to intubation was longer with FFB compared to GLS however, need for external neck manipulation was more with GLS. Conclusion: There was no difference in HDSR due to ET intubation using either GLS or FFB in healthy adult patients with normal airway. Rate pressure product remained within the acceptable range. Professional Medical Publicaitons 2014 /pmc/articles/PMC4163221/ /pubmed/25225515 http://dx.doi.org/10.12669/pjms.305.4788 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Aqil, Mansoor
A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope
title A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope
title_full A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope
title_fullStr A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope
title_full_unstemmed A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope
title_short A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope
title_sort study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4163221/
https://www.ncbi.nlm.nih.gov/pubmed/25225515
http://dx.doi.org/10.12669/pjms.305.4788
work_keys_str_mv AT aqilmansoor astudyofstressresponsetoendotrachealintubationcomparingglidescopeandflexiblefiberopticbronchoscope
AT aqilmansoor studyofstressresponsetoendotrachealintubationcomparingglidescopeandflexiblefiberopticbronchoscope