Cargando…

The effect of insertion angle on orthodontic mini-screw torque

BACKGROUND: Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws. MATERIALS AND METHODS: In this experim...

Descripción completa

Detalles Bibliográficos
Autores principales: Raji, Seyed Hamid, Noorollahian, Saeed, Niknam, Seyed Mohsen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4163822/
https://www.ncbi.nlm.nih.gov/pubmed/25225557
_version_ 1782334868402733056
author Raji, Seyed Hamid
Noorollahian, Saeed
Niknam, Seyed Mohsen
author_facet Raji, Seyed Hamid
Noorollahian, Saeed
Niknam, Seyed Mohsen
author_sort Raji, Seyed Hamid
collection PubMed
description BACKGROUND: Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws. MATERIALS AND METHODS: In this experimental study, 72 mini-screws (Dual Top Anchor System, Jeil, 1.6 mm diameter, 8 mm length) were used. They were randomly divided into four equal groups and inserted in poly-carbonate plates with 3 mm thickness. Then, their maximum insertion torque (MIT) and maximum removal torque (MRT) were recorded using a digital torque tester/screwdriver. Each group had a different insertion angle (90°, 75°, 60° and 45°). The data were analyzed by SPSS software (version 18) using one-way ANOVA and post-hoc Tukey's tests. The level of significance was set at 0.05. RESULTS: The maximum MIT was observed in 45° insertion angle (14.84 Ncm) and the minimum MIT was reported in 75° insertion angle (12.66 Ncm). The maximum MRT was observed in 45° insertion angle (23.21 Ncm) and the minimum MRT was reported in the 90° insertion angle (17.43 Ncm). CONCLUSION: Oblique insertion of the mini-screws results in higher insertion and removal torques and probably more primary stability compared to the vertical insertion.
format Online
Article
Text
id pubmed-4163822
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-41638222014-09-15 The effect of insertion angle on orthodontic mini-screw torque Raji, Seyed Hamid Noorollahian, Saeed Niknam, Seyed Mohsen Dent Res J (Isfahan) Original Article BACKGROUND: Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws. MATERIALS AND METHODS: In this experimental study, 72 mini-screws (Dual Top Anchor System, Jeil, 1.6 mm diameter, 8 mm length) were used. They were randomly divided into four equal groups and inserted in poly-carbonate plates with 3 mm thickness. Then, their maximum insertion torque (MIT) and maximum removal torque (MRT) were recorded using a digital torque tester/screwdriver. Each group had a different insertion angle (90°, 75°, 60° and 45°). The data were analyzed by SPSS software (version 18) using one-way ANOVA and post-hoc Tukey's tests. The level of significance was set at 0.05. RESULTS: The maximum MIT was observed in 45° insertion angle (14.84 Ncm) and the minimum MIT was reported in 75° insertion angle (12.66 Ncm). The maximum MRT was observed in 45° insertion angle (23.21 Ncm) and the minimum MRT was reported in the 90° insertion angle (17.43 Ncm). CONCLUSION: Oblique insertion of the mini-screws results in higher insertion and removal torques and probably more primary stability compared to the vertical insertion. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4163822/ /pubmed/25225557 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Raji, Seyed Hamid
Noorollahian, Saeed
Niknam, Seyed Mohsen
The effect of insertion angle on orthodontic mini-screw torque
title The effect of insertion angle on orthodontic mini-screw torque
title_full The effect of insertion angle on orthodontic mini-screw torque
title_fullStr The effect of insertion angle on orthodontic mini-screw torque
title_full_unstemmed The effect of insertion angle on orthodontic mini-screw torque
title_short The effect of insertion angle on orthodontic mini-screw torque
title_sort effect of insertion angle on orthodontic mini-screw torque
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4163822/
https://www.ncbi.nlm.nih.gov/pubmed/25225557
work_keys_str_mv AT rajiseyedhamid theeffectofinsertionangleonorthodonticminiscrewtorque
AT noorollahiansaeed theeffectofinsertionangleonorthodonticminiscrewtorque
AT niknamseyedmohsen theeffectofinsertionangleonorthodonticminiscrewtorque
AT rajiseyedhamid effectofinsertionangleonorthodonticminiscrewtorque
AT noorollahiansaeed effectofinsertionangleonorthodonticminiscrewtorque
AT niknamseyedmohsen effectofinsertionangleonorthodonticminiscrewtorque