Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study
Drug delivery from a Dry Powder Inhaler (DPI) is dependent on the peak inspiratory flow rate (PIFR) generated. Currently available methods for estimating PIFR from most DPIs are limited and mainly rely on subjective assessment. We aim to show that spirometric and Diskus™ PIFR and Inspiratory Vital C...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4164676/ https://www.ncbi.nlm.nih.gov/pubmed/25279290 http://dx.doi.org/10.1186/2193-1801-3-496 |
_version_ | 1782334985914548224 |
---|---|
author | Seheult, Jansen N Costello, Simon Tee, Kee Chun Bholah, Tariq Al Bannai, Hasan Sulaiman, Imran Costello, Richard W |
author_facet | Seheult, Jansen N Costello, Simon Tee, Kee Chun Bholah, Tariq Al Bannai, Hasan Sulaiman, Imran Costello, Richard W |
author_sort | Seheult, Jansen N |
collection | PubMed |
description | Drug delivery from a Dry Powder Inhaler (DPI) is dependent on the peak inspiratory flow rate (PIFR) generated. Currently available methods for estimating PIFR from most DPIs are limited and mainly rely on subjective assessment. We aim to show that spirometric and Diskus™ PIFR and Inspiratory Vital Capacity (IVC) are related to the underlying respiratory condition and that spirometric PIFR can be used to assess whether Diskus™ PIFR will be adequate when using this DPI. Healthy volunteers and patients with asthma, COPD, neuromuscular disease and non-respiratory disorders were recruited (n = 85). Demographics and baseline lung function by spirometry were recorded. Flow and volume readings were taken while patients used a Diskus™ DPI, housed in an airtight container connected to a spirometer. T-tests were performed to compare mean spirometric and Diskus™ PIFR/ IVC between groups. Stepwise regression analysis of Diskus™ PIFR versus spirometric PIFR, spirometric IVC, age, gender, condition, BMI, FEV1 and FVC was performed. The Diskus™ PIFR for the COPD and Neuromuscular Disease group was more than 10 L/min lower than the Healthy or Asthma groups (p < 0.05). The mean spirometric and Diskus™ IVC of the Healthy group was significantly (>0.75 L) higher than the mean for the other three groups (p < 0.05). Diskus™ PIFR was moderately correlated with spirometric PIFR and age (Adjusted R(2) = 0.58, p < 0.0001). PIFR generated using a Diskus™ DPI is dependent on the underlying disease and age. A spirometric PIFR of less than 196 L/min should prompt further investigation into the suitability of a patient for a Diskus™ DPI, with possible consideration of alternate devices. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/2193-1801-3-496) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4164676 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-41646762014-10-02 Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study Seheult, Jansen N Costello, Simon Tee, Kee Chun Bholah, Tariq Al Bannai, Hasan Sulaiman, Imran Costello, Richard W Springerplus Research Drug delivery from a Dry Powder Inhaler (DPI) is dependent on the peak inspiratory flow rate (PIFR) generated. Currently available methods for estimating PIFR from most DPIs are limited and mainly rely on subjective assessment. We aim to show that spirometric and Diskus™ PIFR and Inspiratory Vital Capacity (IVC) are related to the underlying respiratory condition and that spirometric PIFR can be used to assess whether Diskus™ PIFR will be adequate when using this DPI. Healthy volunteers and patients with asthma, COPD, neuromuscular disease and non-respiratory disorders were recruited (n = 85). Demographics and baseline lung function by spirometry were recorded. Flow and volume readings were taken while patients used a Diskus™ DPI, housed in an airtight container connected to a spirometer. T-tests were performed to compare mean spirometric and Diskus™ PIFR/ IVC between groups. Stepwise regression analysis of Diskus™ PIFR versus spirometric PIFR, spirometric IVC, age, gender, condition, BMI, FEV1 and FVC was performed. The Diskus™ PIFR for the COPD and Neuromuscular Disease group was more than 10 L/min lower than the Healthy or Asthma groups (p < 0.05). The mean spirometric and Diskus™ IVC of the Healthy group was significantly (>0.75 L) higher than the mean for the other three groups (p < 0.05). Diskus™ PIFR was moderately correlated with spirometric PIFR and age (Adjusted R(2) = 0.58, p < 0.0001). PIFR generated using a Diskus™ DPI is dependent on the underlying disease and age. A spirometric PIFR of less than 196 L/min should prompt further investigation into the suitability of a patient for a Diskus™ DPI, with possible consideration of alternate devices. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/2193-1801-3-496) contains supplementary material, which is available to authorized users. Springer International Publishing 2014-09-02 /pmc/articles/PMC4164676/ /pubmed/25279290 http://dx.doi.org/10.1186/2193-1801-3-496 Text en © Seheult et al.; licensee Springer. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. |
spellingShingle | Research Seheult, Jansen N Costello, Simon Tee, Kee Chun Bholah, Tariq Al Bannai, Hasan Sulaiman, Imran Costello, Richard W Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study |
title | Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study |
title_full | Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study |
title_fullStr | Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study |
title_full_unstemmed | Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study |
title_short | Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study |
title_sort | investigating the relationship between peak inspiratory flow rate and volume of inhalation from a diskus™ inhaler and baseline spirometric parameters: a cross-sectional study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4164676/ https://www.ncbi.nlm.nih.gov/pubmed/25279290 http://dx.doi.org/10.1186/2193-1801-3-496 |
work_keys_str_mv | AT seheultjansenn investigatingtherelationshipbetweenpeakinspiratoryflowrateandvolumeofinhalationfromadiskusinhalerandbaselinespirometricparametersacrosssectionalstudy AT costellosimon investigatingtherelationshipbetweenpeakinspiratoryflowrateandvolumeofinhalationfromadiskusinhalerandbaselinespirometricparametersacrosssectionalstudy AT teekeechun investigatingtherelationshipbetweenpeakinspiratoryflowrateandvolumeofinhalationfromadiskusinhalerandbaselinespirometricparametersacrosssectionalstudy AT bholahtariq investigatingtherelationshipbetweenpeakinspiratoryflowrateandvolumeofinhalationfromadiskusinhalerandbaselinespirometricparametersacrosssectionalstudy AT albannaihasan investigatingtherelationshipbetweenpeakinspiratoryflowrateandvolumeofinhalationfromadiskusinhalerandbaselinespirometricparametersacrosssectionalstudy AT sulaimanimran investigatingtherelationshipbetweenpeakinspiratoryflowrateandvolumeofinhalationfromadiskusinhalerandbaselinespirometricparametersacrosssectionalstudy AT costellorichardw investigatingtherelationshipbetweenpeakinspiratoryflowrateandvolumeofinhalationfromadiskusinhalerandbaselinespirometricparametersacrosssectionalstudy |