CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater

CFD analysis of 2-dimensional artificially roughened solar air heater duct with additional circular vortex generator, inserted in inlet section is carried out. Circular transverse ribs on the absorber plate are placed as usual. The analysis is done to investigate the effect of inserting additional v...

Descripción completa

Detalles Bibliográficos
Autores principales: Gawande, Vipin B., Dhoble, A. S., Zodpe, D. B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4165206/
https://www.ncbi.nlm.nih.gov/pubmed/25254251
http://dx.doi.org/10.1155/2014/567257
_version_ 1782335068779315200
author Gawande, Vipin B.
Dhoble, A. S.
Zodpe, D. B.
author_facet Gawande, Vipin B.
Dhoble, A. S.
Zodpe, D. B.
author_sort Gawande, Vipin B.
collection PubMed
description CFD analysis of 2-dimensional artificially roughened solar air heater duct with additional circular vortex generator, inserted in inlet section is carried out. Circular transverse ribs on the absorber plate are placed as usual. The analysis is done to investigate the effect of inserting additional vortex generator on the heat transfer and flow friction characteristics inside the solar air heater duct. This investigation covers relative roughness pitch in the range of 10 ≤ P/e ≤ 25 and relevant Reynolds numbers in the range of 3800 ≤ Re ≤ 18000. Relative roughness height (e/D) is kept constant as 0.03 for analysis. The turbulence created due to additional circular vortex generator increases the heat transfer rate and at the same time there is also increase in friction factor values. For combined arrangement of ribs and vortex generator, maximum Nusselt number is found to be 2.05 times that of the smooth duct. The enhancement in Nusselt number with ribs and additional vortex generator is found to be 1.06 times that of duct using ribs alone. The maximum increase in friction factor with ribs and circular vortex generator is found to be 2.91 times that of the smooth duct. Friction factor in a combined arrangement is 1.114 times that in a duct with ribs alone on the absorber plate. The augmentation in Thermal Enhancement Factor (TEF) with vortex generator in inlet section is found to be 1.06 times more than with circular ribs alone on the absorber plate.
format Online
Article
Text
id pubmed-4165206
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41652062014-09-24 CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater Gawande, Vipin B. Dhoble, A. S. Zodpe, D. B. ScientificWorldJournal Research Article CFD analysis of 2-dimensional artificially roughened solar air heater duct with additional circular vortex generator, inserted in inlet section is carried out. Circular transverse ribs on the absorber plate are placed as usual. The analysis is done to investigate the effect of inserting additional vortex generator on the heat transfer and flow friction characteristics inside the solar air heater duct. This investigation covers relative roughness pitch in the range of 10 ≤ P/e ≤ 25 and relevant Reynolds numbers in the range of 3800 ≤ Re ≤ 18000. Relative roughness height (e/D) is kept constant as 0.03 for analysis. The turbulence created due to additional circular vortex generator increases the heat transfer rate and at the same time there is also increase in friction factor values. For combined arrangement of ribs and vortex generator, maximum Nusselt number is found to be 2.05 times that of the smooth duct. The enhancement in Nusselt number with ribs and additional vortex generator is found to be 1.06 times that of duct using ribs alone. The maximum increase in friction factor with ribs and circular vortex generator is found to be 2.91 times that of the smooth duct. Friction factor in a combined arrangement is 1.114 times that in a duct with ribs alone on the absorber plate. The augmentation in Thermal Enhancement Factor (TEF) with vortex generator in inlet section is found to be 1.06 times more than with circular ribs alone on the absorber plate. Hindawi Publishing Corporation 2014 2014-08-31 /pmc/articles/PMC4165206/ /pubmed/25254251 http://dx.doi.org/10.1155/2014/567257 Text en Copyright © 2014 Vipin B. Gawande et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Gawande, Vipin B.
Dhoble, A. S.
Zodpe, D. B.
CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater
title CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater
title_full CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater
title_fullStr CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater
title_full_unstemmed CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater
title_short CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater
title_sort cfd analysis to study effect of circular vortex generator placed in inlet section to investigate heat transfer aspects of solar air heater
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4165206/
https://www.ncbi.nlm.nih.gov/pubmed/25254251
http://dx.doi.org/10.1155/2014/567257
work_keys_str_mv AT gawandevipinb cfdanalysistostudyeffectofcircularvortexgeneratorplacedininletsectiontoinvestigateheattransferaspectsofsolarairheater
AT dhobleas cfdanalysistostudyeffectofcircularvortexgeneratorplacedininletsectiontoinvestigateheattransferaspectsofsolarairheater
AT zodpedb cfdanalysistostudyeffectofcircularvortexgeneratorplacedininletsectiontoinvestigateheattransferaspectsofsolarairheater