Cargando…
A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS
BACKGROUND: Nasal cannula, beside administering low-flow therapy, showed the capability for the administration of continuous positive airway pressure (CPAP) through high-flow nasal cannula (HFNC). Meeting specific physical criteria of 100% relative humidity (RH) and temperature of 37(°)C are the bas...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166058/ https://www.ncbi.nlm.nih.gov/pubmed/25250286 http://dx.doi.org/10.4103/2277-9175.139188 |
_version_ | 1782335197640916992 |
---|---|
author | Sadeghnia, Alireza Badiei, Zohre Talakesh, Hassan |
author_facet | Sadeghnia, Alireza Badiei, Zohre Talakesh, Hassan |
author_sort | Sadeghnia, Alireza |
collection | PubMed |
description | BACKGROUND: Nasal cannula, beside administering low-flow therapy, showed the capability for the administration of continuous positive airway pressure (CPAP) through high-flow nasal cannula (HFNC). Meeting specific physical criteria of 100% relative humidity (RH) and temperature of 37(°)C are the basic interventional requirements to administer oxygen for the newborns through a nasal cannula. Recently, two systems, MR850 and PMH7000, received the Food and Drug Administration (FDA) approval to administer heated, humidified HFNC (HHHFNC). These systems are evaluated in this study based on their humidifying and heating capabilities. MATERIALS AND METHODS: This study was done as an RCT on newborns weighing 1,000 to 1,500 g recovering from respiratory distress syndrome (RDS) while nCPAP was administered at CDP = 4 cmH(2)O, Fio(2) <30%. Patients were randomized to two groups of 35 receiving HHHFNC after treatment with nCPAP, with one group using MR850 humidifier and the other PMH7000. The patients were compared according to the duration of HHHFNC administration, repeated need for nCPAP respiratory support, the need for invasive ventilation, apnea, chronic lung disease (CLD), nasal trauma, RH, and temperature of the gases. RESULTS: The average time of support with HHHNFC did not show any significant difference in the two groups. There was no significant difference between the groups in the need for nCPAP, invasive ventilation, apnea, nasal trauma, and CLD. The difference in the levels of average temperature and humidity was significant (P value <0.001). CONCLUSION: Although the records of temperature and RH in the PMH7000 system was lower than the records from the MR850 system, no clinical priority was observed for respiratory support with HHHNFC in the two systems. |
format | Online Article Text |
id | pubmed-4166058 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-41660582014-09-23 A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS Sadeghnia, Alireza Badiei, Zohre Talakesh, Hassan Adv Biomed Res Original Article BACKGROUND: Nasal cannula, beside administering low-flow therapy, showed the capability for the administration of continuous positive airway pressure (CPAP) through high-flow nasal cannula (HFNC). Meeting specific physical criteria of 100% relative humidity (RH) and temperature of 37(°)C are the basic interventional requirements to administer oxygen for the newborns through a nasal cannula. Recently, two systems, MR850 and PMH7000, received the Food and Drug Administration (FDA) approval to administer heated, humidified HFNC (HHHFNC). These systems are evaluated in this study based on their humidifying and heating capabilities. MATERIALS AND METHODS: This study was done as an RCT on newborns weighing 1,000 to 1,500 g recovering from respiratory distress syndrome (RDS) while nCPAP was administered at CDP = 4 cmH(2)O, Fio(2) <30%. Patients were randomized to two groups of 35 receiving HHHFNC after treatment with nCPAP, with one group using MR850 humidifier and the other PMH7000. The patients were compared according to the duration of HHHFNC administration, repeated need for nCPAP respiratory support, the need for invasive ventilation, apnea, chronic lung disease (CLD), nasal trauma, RH, and temperature of the gases. RESULTS: The average time of support with HHHNFC did not show any significant difference in the two groups. There was no significant difference between the groups in the need for nCPAP, invasive ventilation, apnea, nasal trauma, and CLD. The difference in the levels of average temperature and humidity was significant (P value <0.001). CONCLUSION: Although the records of temperature and RH in the PMH7000 system was lower than the records from the MR850 system, no clinical priority was observed for respiratory support with HHHNFC in the two systems. Medknow Publications & Media Pvt Ltd 2014-08-19 /pmc/articles/PMC4166058/ /pubmed/25250286 http://dx.doi.org/10.4103/2277-9175.139188 Text en Copyright: © 2014 Sadeghnia. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Original Article Sadeghnia, Alireza Badiei, Zohre Talakesh, Hassan A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS |
title | A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS |
title_full | A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS |
title_fullStr | A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS |
title_full_unstemmed | A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS |
title_short | A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS |
title_sort | comparison of two interventions for hhhfnc in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn rds |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166058/ https://www.ncbi.nlm.nih.gov/pubmed/25250286 http://dx.doi.org/10.4103/2277-9175.139188 |
work_keys_str_mv | AT sadeghniaalireza acomparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds AT badieizohre acomparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds AT talakeshhassan acomparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds AT sadeghniaalireza comparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds AT badieizohre comparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds AT talakeshhassan comparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds |