A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS

BACKGROUND: Nasal cannula, beside administering low-flow therapy, showed the capability for the administration of continuous positive airway pressure (CPAP) through high-flow nasal cannula (HFNC). Meeting specific physical criteria of 100% relative humidity (RH) and temperature of 37(°)C are the bas...

Descripción completa

Detalles Bibliográficos
Autores principales: Sadeghnia, Alireza, Badiei, Zohre, Talakesh, Hassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166058/
https://www.ncbi.nlm.nih.gov/pubmed/25250286
http://dx.doi.org/10.4103/2277-9175.139188
_version_ 1782335197640916992
author Sadeghnia, Alireza
Badiei, Zohre
Talakesh, Hassan
author_facet Sadeghnia, Alireza
Badiei, Zohre
Talakesh, Hassan
author_sort Sadeghnia, Alireza
collection PubMed
description BACKGROUND: Nasal cannula, beside administering low-flow therapy, showed the capability for the administration of continuous positive airway pressure (CPAP) through high-flow nasal cannula (HFNC). Meeting specific physical criteria of 100% relative humidity (RH) and temperature of 37(°)C are the basic interventional requirements to administer oxygen for the newborns through a nasal cannula. Recently, two systems, MR850 and PMH7000, received the Food and Drug Administration (FDA) approval to administer heated, humidified HFNC (HHHFNC). These systems are evaluated in this study based on their humidifying and heating capabilities. MATERIALS AND METHODS: This study was done as an RCT on newborns weighing 1,000 to 1,500 g recovering from respiratory distress syndrome (RDS) while nCPAP was administered at CDP = 4 cmH(2)O, Fio(2) <30%. Patients were randomized to two groups of 35 receiving HHHFNC after treatment with nCPAP, with one group using MR850 humidifier and the other PMH7000. The patients were compared according to the duration of HHHFNC administration, repeated need for nCPAP respiratory support, the need for invasive ventilation, apnea, chronic lung disease (CLD), nasal trauma, RH, and temperature of the gases. RESULTS: The average time of support with HHHNFC did not show any significant difference in the two groups. There was no significant difference between the groups in the need for nCPAP, invasive ventilation, apnea, nasal trauma, and CLD. The difference in the levels of average temperature and humidity was significant (P value <0.001). CONCLUSION: Although the records of temperature and RH in the PMH7000 system was lower than the records from the MR850 system, no clinical priority was observed for respiratory support with HHHNFC in the two systems.
format Online
Article
Text
id pubmed-4166058
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-41660582014-09-23 A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS Sadeghnia, Alireza Badiei, Zohre Talakesh, Hassan Adv Biomed Res Original Article BACKGROUND: Nasal cannula, beside administering low-flow therapy, showed the capability for the administration of continuous positive airway pressure (CPAP) through high-flow nasal cannula (HFNC). Meeting specific physical criteria of 100% relative humidity (RH) and temperature of 37(°)C are the basic interventional requirements to administer oxygen for the newborns through a nasal cannula. Recently, two systems, MR850 and PMH7000, received the Food and Drug Administration (FDA) approval to administer heated, humidified HFNC (HHHFNC). These systems are evaluated in this study based on their humidifying and heating capabilities. MATERIALS AND METHODS: This study was done as an RCT on newborns weighing 1,000 to 1,500 g recovering from respiratory distress syndrome (RDS) while nCPAP was administered at CDP = 4 cmH(2)O, Fio(2) <30%. Patients were randomized to two groups of 35 receiving HHHFNC after treatment with nCPAP, with one group using MR850 humidifier and the other PMH7000. The patients were compared according to the duration of HHHFNC administration, repeated need for nCPAP respiratory support, the need for invasive ventilation, apnea, chronic lung disease (CLD), nasal trauma, RH, and temperature of the gases. RESULTS: The average time of support with HHHNFC did not show any significant difference in the two groups. There was no significant difference between the groups in the need for nCPAP, invasive ventilation, apnea, nasal trauma, and CLD. The difference in the levels of average temperature and humidity was significant (P value <0.001). CONCLUSION: Although the records of temperature and RH in the PMH7000 system was lower than the records from the MR850 system, no clinical priority was observed for respiratory support with HHHNFC in the two systems. Medknow Publications & Media Pvt Ltd 2014-08-19 /pmc/articles/PMC4166058/ /pubmed/25250286 http://dx.doi.org/10.4103/2277-9175.139188 Text en Copyright: © 2014 Sadeghnia. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Article
Sadeghnia, Alireza
Badiei, Zohre
Talakesh, Hassan
A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS
title A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS
title_full A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS
title_fullStr A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS
title_full_unstemmed A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS
title_short A comparison of two interventions for HHHFNC in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn RDS
title_sort comparison of two interventions for hhhfnc in preterm infants weighing 1,000 to 1,500 g in the recovery period of newborn rds
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166058/
https://www.ncbi.nlm.nih.gov/pubmed/25250286
http://dx.doi.org/10.4103/2277-9175.139188
work_keys_str_mv AT sadeghniaalireza acomparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds
AT badieizohre acomparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds
AT talakeshhassan acomparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds
AT sadeghniaalireza comparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds
AT badieizohre comparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds
AT talakeshhassan comparisonoftwointerventionsforhhhfncinpreterminfantsweighing1000to1500gintherecoveryperiodofnewbornrds