Cargando…
Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years
BACKGROUND: Several studies showed that the implementation of the Institute for Healthcare Improvement (IHI) ventilator bundle alone or with other preventive measures are associated with reducing Ventilator-Associated Pneumonia (VAP) rates. However, the association with ventilator utilization was ra...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166069/ https://www.ncbi.nlm.nih.gov/pubmed/25276241 http://dx.doi.org/10.4103/1817-1737.140132 |
_version_ | 1782335200230899712 |
---|---|
author | Al-Thaqafy, Majid S. El-Saed, Aiman Arabi, Yaseen M. Balkhy, Hanan H. |
author_facet | Al-Thaqafy, Majid S. El-Saed, Aiman Arabi, Yaseen M. Balkhy, Hanan H. |
author_sort | Al-Thaqafy, Majid S. |
collection | PubMed |
description | BACKGROUND: Several studies showed that the implementation of the Institute for Healthcare Improvement (IHI) ventilator bundle alone or with other preventive measures are associated with reducing Ventilator-Associated Pneumonia (VAP) rates. However, the association with ventilator utilization was rarely examined and the findings were conflicting. The objectives were to validate the bundle association with VAP rate in a traditionally high VAP environment and to examine its association with ventilator utilization. MATERIALS AND METHODS: The study was conducted at the adult medical-surgical intensive care unit (ICU) at King Abdulaziz Medical City, Saudi Arabia, between 2010 and 2013. VAP data were collected by a prospective targeted surveillance as per Centers for Disease Control and Prevention (CDC)/National Healthcare Safety Network (NHSN) methodology while bundle data were collected by a cross-sectional design as per IHI methodology. RESULTS: Ventilator bundle compliance significantly increased from 90% in 2010 to 97% in 2013 (P for trend < 0.001). On the other hand, VAP rate decreased from 3.6 (per 1000 ventilator days) in 2010 to 1.0 in 2013 (P for trend = 0.054) and ventilator utilization ratio decreased from 0.73 in 2010 to 0.59 in 2013 (P for trend < 0.001). There were negative significant correlations between the trends of ventilator bundle compliance and VAP rate (cross-correlation coefficients −0.63 to 0.07) and ventilator utilization (cross-correlation coefficients −0.18 to −0.63). CONCLUSION: More than 70% improvement of VAP rates and approximately 20% improvement of ventilator utilization were observed during IHI ventilator bundle implementation among adult critical patients in a tertiary care center in Saudi Arabia. Replicating the current finding in multicenter randomized trials is required before establishing any causal link. |
format | Online Article Text |
id | pubmed-4166069 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-41660692014-10-01 Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years Al-Thaqafy, Majid S. El-Saed, Aiman Arabi, Yaseen M. Balkhy, Hanan H. Ann Thorac Med Original Article BACKGROUND: Several studies showed that the implementation of the Institute for Healthcare Improvement (IHI) ventilator bundle alone or with other preventive measures are associated with reducing Ventilator-Associated Pneumonia (VAP) rates. However, the association with ventilator utilization was rarely examined and the findings were conflicting. The objectives were to validate the bundle association with VAP rate in a traditionally high VAP environment and to examine its association with ventilator utilization. MATERIALS AND METHODS: The study was conducted at the adult medical-surgical intensive care unit (ICU) at King Abdulaziz Medical City, Saudi Arabia, between 2010 and 2013. VAP data were collected by a prospective targeted surveillance as per Centers for Disease Control and Prevention (CDC)/National Healthcare Safety Network (NHSN) methodology while bundle data were collected by a cross-sectional design as per IHI methodology. RESULTS: Ventilator bundle compliance significantly increased from 90% in 2010 to 97% in 2013 (P for trend < 0.001). On the other hand, VAP rate decreased from 3.6 (per 1000 ventilator days) in 2010 to 1.0 in 2013 (P for trend = 0.054) and ventilator utilization ratio decreased from 0.73 in 2010 to 0.59 in 2013 (P for trend < 0.001). There were negative significant correlations between the trends of ventilator bundle compliance and VAP rate (cross-correlation coefficients −0.63 to 0.07) and ventilator utilization (cross-correlation coefficients −0.18 to −0.63). CONCLUSION: More than 70% improvement of VAP rates and approximately 20% improvement of ventilator utilization were observed during IHI ventilator bundle implementation among adult critical patients in a tertiary care center in Saudi Arabia. Replicating the current finding in multicenter randomized trials is required before establishing any causal link. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4166069/ /pubmed/25276241 http://dx.doi.org/10.4103/1817-1737.140132 Text en Copyright: © Annals of Thoracic Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Al-Thaqafy, Majid S. El-Saed, Aiman Arabi, Yaseen M. Balkhy, Hanan H. Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years |
title | Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years |
title_full | Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years |
title_fullStr | Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years |
title_full_unstemmed | Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years |
title_short | Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years |
title_sort | association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166069/ https://www.ncbi.nlm.nih.gov/pubmed/25276241 http://dx.doi.org/10.4103/1817-1737.140132 |
work_keys_str_mv | AT althaqafymajids associationofcomplianceofventilatorbundlewithincidenceofventilatorassociatedpneumoniaandventilatorutilizationamongcriticalpatientsover4years AT elsaedaiman associationofcomplianceofventilatorbundlewithincidenceofventilatorassociatedpneumoniaandventilatorutilizationamongcriticalpatientsover4years AT arabiyaseenm associationofcomplianceofventilatorbundlewithincidenceofventilatorassociatedpneumoniaandventilatorutilizationamongcriticalpatientsover4years AT balkhyhananh associationofcomplianceofventilatorbundlewithincidenceofventilatorassociatedpneumoniaandventilatorutilizationamongcriticalpatientsover4years |