Cargando…
Surgical Outcome of Urethroplasty Using Penile Circular Fasciocutaneous Flap for Anterior Urethral Stricture
PURPOSE: Penile circular fasciocutaneous flap urethroplasty is a useful technique for a long anterior urethral stricture due to the flap's hairless nature and ample length. We investigated the surgical outcomes of urethroplasty for a complex anterior urethral stricture, performed using a penile...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society for Sexual Medicine and Andrology
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166375/ https://www.ncbi.nlm.nih.gov/pubmed/25237658 http://dx.doi.org/10.5534/wjmh.2014.32.2.87 |
_version_ | 1782335258388070400 |
---|---|
author | Kim, Kyoung Rok Suh, Jun-Gyo Paick, Jae-Seung Kim, Soo Woong |
author_facet | Kim, Kyoung Rok Suh, Jun-Gyo Paick, Jae-Seung Kim, Soo Woong |
author_sort | Kim, Kyoung Rok |
collection | PubMed |
description | PURPOSE: Penile circular fasciocutaneous flap urethroplasty is a useful technique for a long anterior urethral stricture due to the flap's hairless nature and ample length. We investigated the surgical outcomes of urethroplasty for a complex anterior urethral stricture, performed using a penile circular fasciocutaneous flap. MATERIALS AND METHODS: Between 2008 and 2013, we performed a retrospective review of 29 patients who underwent urethroplasty using a penile circular fasciocutaneous flap and had at least 6 months of follow-up. A total of 20 cases utilized only a fasciocutaneous flap, while 9 cases combined a fasciocutaneous flap with other surgery. Success was defined as no requirement of additional urethral instrumentation. RESULTS: The overall success rate was 68.9% (20 out of 29 cases) at a median follow-up of 19 months. Furthermore, fasciocutaneous flap urethroplasty rendered the actual stricture-free rate of 79.3%. The location of recurrence was mostly at the junction of the flap. Among 9 surgical failures, 5 cases were treated successfully by using an additional surgical procedure. Fistula repair was needed in 1 case 4 months later. Further, periodic urethral dilation was performed in the remaining 3 cases. The failure rate was significantly higher in patients with suprapubic cystostomy than in patients without suprapubic cystostomy. The most common complication was post-micturition dribbling. CONCLUSIONS: Penile circular fasciocutaneous flap urethroplasty is a useful method for the reconstruction of a long anterior urethral stricture. A sufficient healthy margin should be acquired for better surgical results due to the fact that most recurrence occurs at the junction of the flap. |
format | Online Article Text |
id | pubmed-4166375 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Korean Society for Sexual Medicine and Andrology |
record_format | MEDLINE/PubMed |
spelling | pubmed-41663752014-09-18 Surgical Outcome of Urethroplasty Using Penile Circular Fasciocutaneous Flap for Anterior Urethral Stricture Kim, Kyoung Rok Suh, Jun-Gyo Paick, Jae-Seung Kim, Soo Woong World J Mens Health Original Article PURPOSE: Penile circular fasciocutaneous flap urethroplasty is a useful technique for a long anterior urethral stricture due to the flap's hairless nature and ample length. We investigated the surgical outcomes of urethroplasty for a complex anterior urethral stricture, performed using a penile circular fasciocutaneous flap. MATERIALS AND METHODS: Between 2008 and 2013, we performed a retrospective review of 29 patients who underwent urethroplasty using a penile circular fasciocutaneous flap and had at least 6 months of follow-up. A total of 20 cases utilized only a fasciocutaneous flap, while 9 cases combined a fasciocutaneous flap with other surgery. Success was defined as no requirement of additional urethral instrumentation. RESULTS: The overall success rate was 68.9% (20 out of 29 cases) at a median follow-up of 19 months. Furthermore, fasciocutaneous flap urethroplasty rendered the actual stricture-free rate of 79.3%. The location of recurrence was mostly at the junction of the flap. Among 9 surgical failures, 5 cases were treated successfully by using an additional surgical procedure. Fistula repair was needed in 1 case 4 months later. Further, periodic urethral dilation was performed in the remaining 3 cases. The failure rate was significantly higher in patients with suprapubic cystostomy than in patients without suprapubic cystostomy. The most common complication was post-micturition dribbling. CONCLUSIONS: Penile circular fasciocutaneous flap urethroplasty is a useful method for the reconstruction of a long anterior urethral stricture. A sufficient healthy margin should be acquired for better surgical results due to the fact that most recurrence occurs at the junction of the flap. Korean Society for Sexual Medicine and Andrology 2014-08 2014-08-26 /pmc/articles/PMC4166375/ /pubmed/25237658 http://dx.doi.org/10.5534/wjmh.2014.32.2.87 Text en Copyright © 2014 Korean Society for Sexual Medicine and Andrology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Kyoung Rok Suh, Jun-Gyo Paick, Jae-Seung Kim, Soo Woong Surgical Outcome of Urethroplasty Using Penile Circular Fasciocutaneous Flap for Anterior Urethral Stricture |
title | Surgical Outcome of Urethroplasty Using Penile Circular Fasciocutaneous Flap for Anterior Urethral Stricture |
title_full | Surgical Outcome of Urethroplasty Using Penile Circular Fasciocutaneous Flap for Anterior Urethral Stricture |
title_fullStr | Surgical Outcome of Urethroplasty Using Penile Circular Fasciocutaneous Flap for Anterior Urethral Stricture |
title_full_unstemmed | Surgical Outcome of Urethroplasty Using Penile Circular Fasciocutaneous Flap for Anterior Urethral Stricture |
title_short | Surgical Outcome of Urethroplasty Using Penile Circular Fasciocutaneous Flap for Anterior Urethral Stricture |
title_sort | surgical outcome of urethroplasty using penile circular fasciocutaneous flap for anterior urethral stricture |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166375/ https://www.ncbi.nlm.nih.gov/pubmed/25237658 http://dx.doi.org/10.5534/wjmh.2014.32.2.87 |
work_keys_str_mv | AT kimkyoungrok surgicaloutcomeofurethroplastyusingpenilecircularfasciocutaneousflapforanteriorurethralstricture AT suhjungyo surgicaloutcomeofurethroplastyusingpenilecircularfasciocutaneousflapforanteriorurethralstricture AT paickjaeseung surgicaloutcomeofurethroplastyusingpenilecircularfasciocutaneousflapforanteriorurethralstricture AT kimsoowoong surgicaloutcomeofurethroplastyusingpenilecircularfasciocutaneousflapforanteriorurethralstricture |