Temporary Sternoclavicular Plating for an Unusual Double Clavicle Fracture (Medial Nonunion, Lateral Acute) Complicated by an Intraoperative Pneumothorax

Double (segmental) clavicle fractures, involving both the medial and lateral aspects of the clavicle, are very uncommon. Even less common is an asynchronous double fracture with one of the fractures being a nonunion. We report the case of a 30-year-old healthy male patient who had an unusual double...

Descripción completa

Detalles Bibliográficos
Autores principales: Skedros, John G., Knight, Alex N., Mears, Chad S., Langston, Tanner D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166450/
https://www.ncbi.nlm.nih.gov/pubmed/25258689
http://dx.doi.org/10.1155/2014/206125
_version_ 1782335273341812736
author Skedros, John G.
Knight, Alex N.
Mears, Chad S.
Langston, Tanner D.
author_facet Skedros, John G.
Knight, Alex N.
Mears, Chad S.
Langston, Tanner D.
author_sort Skedros, John G.
collection PubMed
description Double (segmental) clavicle fractures, involving both the medial and lateral aspects of the clavicle, are very uncommon. Even less common is an asynchronous double fracture with one of the fractures being a nonunion. We report the case of a 30-year-old healthy male patient who had an unusual double clavicle fracture (medial nonunion, lateral acute) that occurred in separate traumatic events during motocross (motorcycle) racing. His fractures were treated surgically in two stages. In the first stage a long reconstruction plate was used that spanned onto the sternum and two transcortical screws were placed into the manubrium to enhance purchase for the deficient bone of the medial clavicle. In accordance with the preoperative plan, the medial one-third of the plate and the medial four screws (of the total 13 used) were removed. Although our patient had an excellent final result, he did have an intraoperative pneumothorax that was treated uneventfully with a chest tube. Medial clavicle fractures are difficult to treat, especially if they are nonunions and surgical complication rates can be high. Our case is one of the few that has been described where temporary sternoclavicular plating was successful in achieving an excellent long-term outcome.
format Online
Article
Text
id pubmed-4166450
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41664502014-09-25 Temporary Sternoclavicular Plating for an Unusual Double Clavicle Fracture (Medial Nonunion, Lateral Acute) Complicated by an Intraoperative Pneumothorax Skedros, John G. Knight, Alex N. Mears, Chad S. Langston, Tanner D. Case Rep Orthop Case Report Double (segmental) clavicle fractures, involving both the medial and lateral aspects of the clavicle, are very uncommon. Even less common is an asynchronous double fracture with one of the fractures being a nonunion. We report the case of a 30-year-old healthy male patient who had an unusual double clavicle fracture (medial nonunion, lateral acute) that occurred in separate traumatic events during motocross (motorcycle) racing. His fractures were treated surgically in two stages. In the first stage a long reconstruction plate was used that spanned onto the sternum and two transcortical screws were placed into the manubrium to enhance purchase for the deficient bone of the medial clavicle. In accordance with the preoperative plan, the medial one-third of the plate and the medial four screws (of the total 13 used) were removed. Although our patient had an excellent final result, he did have an intraoperative pneumothorax that was treated uneventfully with a chest tube. Medial clavicle fractures are difficult to treat, especially if they are nonunions and surgical complication rates can be high. Our case is one of the few that has been described where temporary sternoclavicular plating was successful in achieving an excellent long-term outcome. Hindawi Publishing Corporation 2014 2014-09-02 /pmc/articles/PMC4166450/ /pubmed/25258689 http://dx.doi.org/10.1155/2014/206125 Text en Copyright © 2014 John G. Skedros et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Skedros, John G.
Knight, Alex N.
Mears, Chad S.
Langston, Tanner D.
Temporary Sternoclavicular Plating for an Unusual Double Clavicle Fracture (Medial Nonunion, Lateral Acute) Complicated by an Intraoperative Pneumothorax
title Temporary Sternoclavicular Plating for an Unusual Double Clavicle Fracture (Medial Nonunion, Lateral Acute) Complicated by an Intraoperative Pneumothorax
title_full Temporary Sternoclavicular Plating for an Unusual Double Clavicle Fracture (Medial Nonunion, Lateral Acute) Complicated by an Intraoperative Pneumothorax
title_fullStr Temporary Sternoclavicular Plating for an Unusual Double Clavicle Fracture (Medial Nonunion, Lateral Acute) Complicated by an Intraoperative Pneumothorax
title_full_unstemmed Temporary Sternoclavicular Plating for an Unusual Double Clavicle Fracture (Medial Nonunion, Lateral Acute) Complicated by an Intraoperative Pneumothorax
title_short Temporary Sternoclavicular Plating for an Unusual Double Clavicle Fracture (Medial Nonunion, Lateral Acute) Complicated by an Intraoperative Pneumothorax
title_sort temporary sternoclavicular plating for an unusual double clavicle fracture (medial nonunion, lateral acute) complicated by an intraoperative pneumothorax
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166450/
https://www.ncbi.nlm.nih.gov/pubmed/25258689
http://dx.doi.org/10.1155/2014/206125
work_keys_str_mv AT skedrosjohng temporarysternoclavicularplatingforanunusualdoubleclaviclefracturemedialnonunionlateralacutecomplicatedbyanintraoperativepneumothorax
AT knightalexn temporarysternoclavicularplatingforanunusualdoubleclaviclefracturemedialnonunionlateralacutecomplicatedbyanintraoperativepneumothorax
AT mearschads temporarysternoclavicularplatingforanunusualdoubleclaviclefracturemedialnonunionlateralacutecomplicatedbyanintraoperativepneumothorax
AT langstontannerd temporarysternoclavicularplatingforanunusualdoubleclaviclefracturemedialnonunionlateralacutecomplicatedbyanintraoperativepneumothorax