A Comparative Study of Newly Developed HPLC-DAD and UHPLC-UV Assays for the Determination of Posaconazole in Bulk Powder and Suspension Dosage Form

Objective. To develop and compare HPLC-DAD and UHPLC-UV assays for the quantitation of posaconazole in bulk powder and suspension dosage form. Methods. Posaconazole linearity range was 5–50 μg/mL for both assays. For HPLC-DAD assay, samples were injected through Zorbax SB-C18 (4.6 × 250 mm, 5 μm) co...

Descripción completa

Detalles Bibliográficos
Autores principales: Hamdy, Dalia A., Belal, Tarek S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4167226/
https://www.ncbi.nlm.nih.gov/pubmed/25258695
http://dx.doi.org/10.1155/2014/241035
_version_ 1782335385317146624
author Hamdy, Dalia A.
Belal, Tarek S.
author_facet Hamdy, Dalia A.
Belal, Tarek S.
author_sort Hamdy, Dalia A.
collection PubMed
description Objective. To develop and compare HPLC-DAD and UHPLC-UV assays for the quantitation of posaconazole in bulk powder and suspension dosage form. Methods. Posaconazole linearity range was 5–50 μg/mL for both assays. For HPLC-DAD assay, samples were injected through Zorbax SB-C18 (4.6 × 250 mm, 5 μm) column. The gradient elution composed of the mobile phase acetonitrile: 15 mM potassium dihydrogen orthophosphate (30 : 70 to 80 : 20, linear over 7 minutes) pumped at 1.5 mL/min. For UHPLC-UV assay, samples were injected through Kinetex-C18 (2.1 × 50 mm, 1.3 μm) column. The mobile phase composed of acetonitrile: 15 mM potassium dihydrogen orthophosphate (45 : 55) pumped isocratically at 0.4 mL/min. Detection wavelength was 262 nm in both methods. Results. The run time was 11 and 3 minutes for HPLC-DAD and UHPLC-UV assays, respectively. Both assays were linear (r (2) > 0.999) with CV% and % error of the mean <3%. Limits of detection and quantitation were 0.82 and 2.73 μg/mL for HPLC-DAD and 1.04 and 3.16 μg/mL for UHPLC-UV, respectively. The methods quantitated PSZ in suspension dosage form with no observable interferences. Conclusions. Both assays were proven sensitive and selective according to ICH guidelines. UHPLC-UV assay exhibited some economic and chromatographic separation superiority.
format Online
Article
Text
id pubmed-4167226
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41672262014-09-25 A Comparative Study of Newly Developed HPLC-DAD and UHPLC-UV Assays for the Determination of Posaconazole in Bulk Powder and Suspension Dosage Form Hamdy, Dalia A. Belal, Tarek S. J Anal Methods Chem Research Article Objective. To develop and compare HPLC-DAD and UHPLC-UV assays for the quantitation of posaconazole in bulk powder and suspension dosage form. Methods. Posaconazole linearity range was 5–50 μg/mL for both assays. For HPLC-DAD assay, samples were injected through Zorbax SB-C18 (4.6 × 250 mm, 5 μm) column. The gradient elution composed of the mobile phase acetonitrile: 15 mM potassium dihydrogen orthophosphate (30 : 70 to 80 : 20, linear over 7 minutes) pumped at 1.5 mL/min. For UHPLC-UV assay, samples were injected through Kinetex-C18 (2.1 × 50 mm, 1.3 μm) column. The mobile phase composed of acetonitrile: 15 mM potassium dihydrogen orthophosphate (45 : 55) pumped isocratically at 0.4 mL/min. Detection wavelength was 262 nm in both methods. Results. The run time was 11 and 3 minutes for HPLC-DAD and UHPLC-UV assays, respectively. Both assays were linear (r (2) > 0.999) with CV% and % error of the mean <3%. Limits of detection and quantitation were 0.82 and 2.73 μg/mL for HPLC-DAD and 1.04 and 3.16 μg/mL for UHPLC-UV, respectively. The methods quantitated PSZ in suspension dosage form with no observable interferences. Conclusions. Both assays were proven sensitive and selective according to ICH guidelines. UHPLC-UV assay exhibited some economic and chromatographic separation superiority. Hindawi Publishing Corporation 2014 2014-09-03 /pmc/articles/PMC4167226/ /pubmed/25258695 http://dx.doi.org/10.1155/2014/241035 Text en Copyright © 2014 D. A. Hamdy and T. S. Belal. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hamdy, Dalia A.
Belal, Tarek S.
A Comparative Study of Newly Developed HPLC-DAD and UHPLC-UV Assays for the Determination of Posaconazole in Bulk Powder and Suspension Dosage Form
title A Comparative Study of Newly Developed HPLC-DAD and UHPLC-UV Assays for the Determination of Posaconazole in Bulk Powder and Suspension Dosage Form
title_full A Comparative Study of Newly Developed HPLC-DAD and UHPLC-UV Assays for the Determination of Posaconazole in Bulk Powder and Suspension Dosage Form
title_fullStr A Comparative Study of Newly Developed HPLC-DAD and UHPLC-UV Assays for the Determination of Posaconazole in Bulk Powder and Suspension Dosage Form
title_full_unstemmed A Comparative Study of Newly Developed HPLC-DAD and UHPLC-UV Assays for the Determination of Posaconazole in Bulk Powder and Suspension Dosage Form
title_short A Comparative Study of Newly Developed HPLC-DAD and UHPLC-UV Assays for the Determination of Posaconazole in Bulk Powder and Suspension Dosage Form
title_sort comparative study of newly developed hplc-dad and uhplc-uv assays for the determination of posaconazole in bulk powder and suspension dosage form
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4167226/
https://www.ncbi.nlm.nih.gov/pubmed/25258695
http://dx.doi.org/10.1155/2014/241035
work_keys_str_mv AT hamdydaliaa acomparativestudyofnewlydevelopedhplcdadanduhplcuvassaysforthedeterminationofposaconazoleinbulkpowderandsuspensiondosageform
AT belaltareks acomparativestudyofnewlydevelopedhplcdadanduhplcuvassaysforthedeterminationofposaconazoleinbulkpowderandsuspensiondosageform
AT hamdydaliaa comparativestudyofnewlydevelopedhplcdadanduhplcuvassaysforthedeterminationofposaconazoleinbulkpowderandsuspensiondosageform
AT belaltareks comparativestudyofnewlydevelopedhplcdadanduhplcuvassaysforthedeterminationofposaconazoleinbulkpowderandsuspensiondosageform