Cargando…
Surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes
The introduction of both new surgical devices and reengineered existing devices leads to modifications in the way traditional tasks are carried out and allows for the development of new surgical techniques. Each new device has benefits and limitations in regards to tissue interactions that, if known...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4168870/ https://www.ncbi.nlm.nih.gov/pubmed/25246812 http://dx.doi.org/10.2147/MDER.S67338 |
_version_ | 1782335634604556288 |
---|---|
author | Chekan, Edward Whelan, Richard L |
author_facet | Chekan, Edward Whelan, Richard L |
author_sort | Chekan, Edward |
collection | PubMed |
description | The introduction of both new surgical devices and reengineered existing devices leads to modifications in the way traditional tasks are carried out and allows for the development of new surgical techniques. Each new device has benefits and limitations in regards to tissue interactions that, if known, allow for optimal use. However, most surgeons are unaware of these attributes and, therefore, new device introduction creates a “knowledge gap” that is potentially dangerous. The goal of this review is to present a framework for the study of device– tissue interactions and to initiate the process of “filling in” the knowledge gap via the available literature. Surgical staplers, which are continually being developed, are the focus of this piece. The integrity of the staple line, which depends on adequate tissue compression, is the primary factor in creating a stable anastomosis. This review focuses on published studies that evaluated the creation of stable anastomoses in bariatric, thoracic, and colorectal procedures. Understanding how staplers interact with target tissues is key to improving patient outcomes. It is clear from this review that each tissue type presents unique challenges. The thickness of each tissue varies as do the intrinsic biomechanical properties that determine the ideal compressive force and prefiring compression time for each tissue type. The correct staple height will vary depending on these tissue-specific properties and the tissue pathology. These studies reinforce the universal theme that compression, staple height, tissue thickness, tissue compressibility, and tissue type must all be considered by the surgeon prior to choosing a stapler and cartridge. The surgeon’s experience, therefore, is a critical factor. Educational programs need to be established to inform and update surgeons on the characteristics of each stapler. It is hoped that the framework presented in this review will facilitate this process. |
format | Online Article Text |
id | pubmed-4168870 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-41688702014-09-22 Surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes Chekan, Edward Whelan, Richard L Med Devices (Auckl) Review The introduction of both new surgical devices and reengineered existing devices leads to modifications in the way traditional tasks are carried out and allows for the development of new surgical techniques. Each new device has benefits and limitations in regards to tissue interactions that, if known, allow for optimal use. However, most surgeons are unaware of these attributes and, therefore, new device introduction creates a “knowledge gap” that is potentially dangerous. The goal of this review is to present a framework for the study of device– tissue interactions and to initiate the process of “filling in” the knowledge gap via the available literature. Surgical staplers, which are continually being developed, are the focus of this piece. The integrity of the staple line, which depends on adequate tissue compression, is the primary factor in creating a stable anastomosis. This review focuses on published studies that evaluated the creation of stable anastomoses in bariatric, thoracic, and colorectal procedures. Understanding how staplers interact with target tissues is key to improving patient outcomes. It is clear from this review that each tissue type presents unique challenges. The thickness of each tissue varies as do the intrinsic biomechanical properties that determine the ideal compressive force and prefiring compression time for each tissue type. The correct staple height will vary depending on these tissue-specific properties and the tissue pathology. These studies reinforce the universal theme that compression, staple height, tissue thickness, tissue compressibility, and tissue type must all be considered by the surgeon prior to choosing a stapler and cartridge. The surgeon’s experience, therefore, is a critical factor. Educational programs need to be established to inform and update surgeons on the characteristics of each stapler. It is hoped that the framework presented in this review will facilitate this process. Dove Medical Press 2014-09-12 /pmc/articles/PMC4168870/ /pubmed/25246812 http://dx.doi.org/10.2147/MDER.S67338 Text en © 2014 Chekan and Whelan. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Review Chekan, Edward Whelan, Richard L Surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes |
title | Surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes |
title_full | Surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes |
title_fullStr | Surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes |
title_full_unstemmed | Surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes |
title_short | Surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes |
title_sort | surgical stapling device–tissue interactions: what surgeons need to know to improve patient outcomes |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4168870/ https://www.ncbi.nlm.nih.gov/pubmed/25246812 http://dx.doi.org/10.2147/MDER.S67338 |
work_keys_str_mv | AT chekanedward surgicalstaplingdevicetissueinteractionswhatsurgeonsneedtoknowtoimprovepatientoutcomes AT whelanrichardl surgicalstaplingdevicetissueinteractionswhatsurgeonsneedtoknowtoimprovepatientoutcomes |