Cargando…

Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy

BACKGROUND: Stroke is the second leading cause of death globally. Computerized tomography is used to distinguish between ischemic and hemorrhagic subtypes, but it is expensive and unavailable in low and middle income countries. Clinical stroke scores are proposed to differentiate between stroke subt...

Descripción completa

Detalles Bibliográficos
Autores principales: Mwita, Clifford C., Kajia, Duncan, Gwer, Samson, Etyang, Anthony, Newton, Charles R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4173228/
https://www.ncbi.nlm.nih.gov/pubmed/25288833
http://dx.doi.org/10.4103/0976-3147.139966
_version_ 1782336148050280448
author Mwita, Clifford C.
Kajia, Duncan
Gwer, Samson
Etyang, Anthony
Newton, Charles R.
author_facet Mwita, Clifford C.
Kajia, Duncan
Gwer, Samson
Etyang, Anthony
Newton, Charles R.
author_sort Mwita, Clifford C.
collection PubMed
description BACKGROUND: Stroke is the second leading cause of death globally. Computerized tomography is used to distinguish between ischemic and hemorrhagic subtypes, but it is expensive and unavailable in low and middle income countries. Clinical stroke scores are proposed to differentiate between stroke subtypes but their reliability is unknown. MATERIALS AND METHODS: We searched online databases for studies written in English and identified articles using predefined criteria. We considered studies in which the Siriraj, Guy's Hospital, Besson and Greek stroke scores were compared to computerized tomography as the reference standard. We calculated the pooled sensitivity and specificity of the clinical stroke scores using a bivariate mixed effects binomial regression model. RESULTS: In meta-analysis, sensitivity and specificity for the Siriraj stroke score, were 0.69 (95% CI 0.62-0.75) and 0.83 (95% CI 0.75-0.88) for ischemic stroke and 0.65 (95% CI 0.56-0.73) and 0.88 (95% CI 0.83-0.91) for hemorrhagic stroke. For the Guy's hospital stroke score overall sensitivity and specificity were 0.70 (95% CI 0.53-0.83) and 0.79 (95% CI 0.68-0.87) for ischemic stroke and 0.54 (95% CI 0.42-0.66) and 0.89 (95% CI 0.83-0.94) for hemorrhagic stroke. CONCLUSIONS: Clinical stroke scores are not accurate enough for use in clinical or epidemiological settings. Computerized tomography is recommended for differentiating stroke subtypes. Larger studies using different patient populations are required for validation of clinical stroke scores.
format Online
Article
Text
id pubmed-4173228
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-41732282014-10-07 Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy Mwita, Clifford C. Kajia, Duncan Gwer, Samson Etyang, Anthony Newton, Charles R. J Neurosci Rural Pract Original Article BACKGROUND: Stroke is the second leading cause of death globally. Computerized tomography is used to distinguish between ischemic and hemorrhagic subtypes, but it is expensive and unavailable in low and middle income countries. Clinical stroke scores are proposed to differentiate between stroke subtypes but their reliability is unknown. MATERIALS AND METHODS: We searched online databases for studies written in English and identified articles using predefined criteria. We considered studies in which the Siriraj, Guy's Hospital, Besson and Greek stroke scores were compared to computerized tomography as the reference standard. We calculated the pooled sensitivity and specificity of the clinical stroke scores using a bivariate mixed effects binomial regression model. RESULTS: In meta-analysis, sensitivity and specificity for the Siriraj stroke score, were 0.69 (95% CI 0.62-0.75) and 0.83 (95% CI 0.75-0.88) for ischemic stroke and 0.65 (95% CI 0.56-0.73) and 0.88 (95% CI 0.83-0.91) for hemorrhagic stroke. For the Guy's hospital stroke score overall sensitivity and specificity were 0.70 (95% CI 0.53-0.83) and 0.79 (95% CI 0.68-0.87) for ischemic stroke and 0.54 (95% CI 0.42-0.66) and 0.89 (95% CI 0.83-0.94) for hemorrhagic stroke. CONCLUSIONS: Clinical stroke scores are not accurate enough for use in clinical or epidemiological settings. Computerized tomography is recommended for differentiating stroke subtypes. Larger studies using different patient populations are required for validation of clinical stroke scores. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4173228/ /pubmed/25288833 http://dx.doi.org/10.4103/0976-3147.139966 Text en Copyright: © Journal of Neurosciences in Rural Practice http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Mwita, Clifford C.
Kajia, Duncan
Gwer, Samson
Etyang, Anthony
Newton, Charles R.
Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy
title Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy
title_full Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy
title_fullStr Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy
title_full_unstemmed Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy
title_short Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy
title_sort accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: a systematic review of diagnostic test accuracy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4173228/
https://www.ncbi.nlm.nih.gov/pubmed/25288833
http://dx.doi.org/10.4103/0976-3147.139966
work_keys_str_mv AT mwitacliffordc accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy
AT kajiaduncan accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy
AT gwersamson accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy
AT etyanganthony accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy
AT newtoncharlesr accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy