Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy
BACKGROUND: Stroke is the second leading cause of death globally. Computerized tomography is used to distinguish between ischemic and hemorrhagic subtypes, but it is expensive and unavailable in low and middle income countries. Clinical stroke scores are proposed to differentiate between stroke subt...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4173228/ https://www.ncbi.nlm.nih.gov/pubmed/25288833 http://dx.doi.org/10.4103/0976-3147.139966 |
_version_ | 1782336148050280448 |
---|---|
author | Mwita, Clifford C. Kajia, Duncan Gwer, Samson Etyang, Anthony Newton, Charles R. |
author_facet | Mwita, Clifford C. Kajia, Duncan Gwer, Samson Etyang, Anthony Newton, Charles R. |
author_sort | Mwita, Clifford C. |
collection | PubMed |
description | BACKGROUND: Stroke is the second leading cause of death globally. Computerized tomography is used to distinguish between ischemic and hemorrhagic subtypes, but it is expensive and unavailable in low and middle income countries. Clinical stroke scores are proposed to differentiate between stroke subtypes but their reliability is unknown. MATERIALS AND METHODS: We searched online databases for studies written in English and identified articles using predefined criteria. We considered studies in which the Siriraj, Guy's Hospital, Besson and Greek stroke scores were compared to computerized tomography as the reference standard. We calculated the pooled sensitivity and specificity of the clinical stroke scores using a bivariate mixed effects binomial regression model. RESULTS: In meta-analysis, sensitivity and specificity for the Siriraj stroke score, were 0.69 (95% CI 0.62-0.75) and 0.83 (95% CI 0.75-0.88) for ischemic stroke and 0.65 (95% CI 0.56-0.73) and 0.88 (95% CI 0.83-0.91) for hemorrhagic stroke. For the Guy's hospital stroke score overall sensitivity and specificity were 0.70 (95% CI 0.53-0.83) and 0.79 (95% CI 0.68-0.87) for ischemic stroke and 0.54 (95% CI 0.42-0.66) and 0.89 (95% CI 0.83-0.94) for hemorrhagic stroke. CONCLUSIONS: Clinical stroke scores are not accurate enough for use in clinical or epidemiological settings. Computerized tomography is recommended for differentiating stroke subtypes. Larger studies using different patient populations are required for validation of clinical stroke scores. |
format | Online Article Text |
id | pubmed-4173228 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-41732282014-10-07 Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy Mwita, Clifford C. Kajia, Duncan Gwer, Samson Etyang, Anthony Newton, Charles R. J Neurosci Rural Pract Original Article BACKGROUND: Stroke is the second leading cause of death globally. Computerized tomography is used to distinguish between ischemic and hemorrhagic subtypes, but it is expensive and unavailable in low and middle income countries. Clinical stroke scores are proposed to differentiate between stroke subtypes but their reliability is unknown. MATERIALS AND METHODS: We searched online databases for studies written in English and identified articles using predefined criteria. We considered studies in which the Siriraj, Guy's Hospital, Besson and Greek stroke scores were compared to computerized tomography as the reference standard. We calculated the pooled sensitivity and specificity of the clinical stroke scores using a bivariate mixed effects binomial regression model. RESULTS: In meta-analysis, sensitivity and specificity for the Siriraj stroke score, were 0.69 (95% CI 0.62-0.75) and 0.83 (95% CI 0.75-0.88) for ischemic stroke and 0.65 (95% CI 0.56-0.73) and 0.88 (95% CI 0.83-0.91) for hemorrhagic stroke. For the Guy's hospital stroke score overall sensitivity and specificity were 0.70 (95% CI 0.53-0.83) and 0.79 (95% CI 0.68-0.87) for ischemic stroke and 0.54 (95% CI 0.42-0.66) and 0.89 (95% CI 0.83-0.94) for hemorrhagic stroke. CONCLUSIONS: Clinical stroke scores are not accurate enough for use in clinical or epidemiological settings. Computerized tomography is recommended for differentiating stroke subtypes. Larger studies using different patient populations are required for validation of clinical stroke scores. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4173228/ /pubmed/25288833 http://dx.doi.org/10.4103/0976-3147.139966 Text en Copyright: © Journal of Neurosciences in Rural Practice http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mwita, Clifford C. Kajia, Duncan Gwer, Samson Etyang, Anthony Newton, Charles R. Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy |
title | Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy |
title_full | Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy |
title_fullStr | Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy |
title_full_unstemmed | Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy |
title_short | Accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: A systematic review of diagnostic test accuracy |
title_sort | accuracy of clinical stroke scores for distinguishing stroke subtypes in resource poor settings: a systematic review of diagnostic test accuracy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4173228/ https://www.ncbi.nlm.nih.gov/pubmed/25288833 http://dx.doi.org/10.4103/0976-3147.139966 |
work_keys_str_mv | AT mwitacliffordc accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy AT kajiaduncan accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy AT gwersamson accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy AT etyanganthony accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy AT newtoncharlesr accuracyofclinicalstrokescoresfordistinguishingstrokesubtypesinresourcepoorsettingsasystematicreviewofdiagnostictestaccuracy |