Cargando…

Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening

[Image: see text] Apart from texture, the human finger can sense palpation. The detection of an imbedded structure is a fine balance between the relative stiffness of the matrix, the object, and the device. If the device is too soft, its high responsiveness will limit the depth to which the imbedded...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, Chieu Van, Saraf, Ravi F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4173743/
https://www.ncbi.nlm.nih.gov/pubmed/25148477
http://dx.doi.org/10.1021/am5046789
_version_ 1782336250638761984
author Nguyen, Chieu Van
Saraf, Ravi F.
author_facet Nguyen, Chieu Van
Saraf, Ravi F.
author_sort Nguyen, Chieu Van
collection PubMed
description [Image: see text] Apart from texture, the human finger can sense palpation. The detection of an imbedded structure is a fine balance between the relative stiffness of the matrix, the object, and the device. If the device is too soft, its high responsiveness will limit the depth to which the imbedded structure can be detected. The sensation of palpation is an effective procedure for a physician to examine irregularities. In a clinical breast examination (CBE), by pressing over 1 cm(2) area, at a contact pressure in the 70–90 kPa range, the physician feels cancerous lumps that are 8- to 18-fold stiffer than surrounding tissue. Early detection of a lump in the 5–10 mm range leads to an excellent prognosis. We describe a thin-film tactile device that emulates human touch to quantify CBE by imaging the size and shape of 5–10 mm objects at 20 mm depth in a breast model using ∼80 kPa pressure. The linear response of the device allows quantification where the greyscale corresponds to the relative local stiffness. The (background) signal from <2.5-fold stiffer objects at a size below 2 mm is minimal.
format Online
Article
Text
id pubmed-4173743
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-41737432015-08-22 Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening Nguyen, Chieu Van Saraf, Ravi F. ACS Appl Mater Interfaces [Image: see text] Apart from texture, the human finger can sense palpation. The detection of an imbedded structure is a fine balance between the relative stiffness of the matrix, the object, and the device. If the device is too soft, its high responsiveness will limit the depth to which the imbedded structure can be detected. The sensation of palpation is an effective procedure for a physician to examine irregularities. In a clinical breast examination (CBE), by pressing over 1 cm(2) area, at a contact pressure in the 70–90 kPa range, the physician feels cancerous lumps that are 8- to 18-fold stiffer than surrounding tissue. Early detection of a lump in the 5–10 mm range leads to an excellent prognosis. We describe a thin-film tactile device that emulates human touch to quantify CBE by imaging the size and shape of 5–10 mm objects at 20 mm depth in a breast model using ∼80 kPa pressure. The linear response of the device allows quantification where the greyscale corresponds to the relative local stiffness. The (background) signal from <2.5-fold stiffer objects at a size below 2 mm is minimal. American Chemical Society 2014-08-22 2014-09-24 /pmc/articles/PMC4173743/ /pubmed/25148477 http://dx.doi.org/10.1021/am5046789 Text en Copyright © 2014 American Chemical Society Terms of Use (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html)
spellingShingle Nguyen, Chieu Van
Saraf, Ravi F.
Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening
title Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening
title_full Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening
title_fullStr Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening
title_full_unstemmed Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening
title_short Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening
title_sort tactile imaging of an imbedded palpable structure for breast cancer screening
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4173743/
https://www.ncbi.nlm.nih.gov/pubmed/25148477
http://dx.doi.org/10.1021/am5046789
work_keys_str_mv AT nguyenchieuvan tactileimagingofanimbeddedpalpablestructureforbreastcancerscreening
AT sarafravif tactileimagingofanimbeddedpalpablestructureforbreastcancerscreening