Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

INTRODUCTION: This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy...

Descripción completa

Detalles Bibliográficos
Autores principales: Crowe, Scott B, Kairn, Tanya, Middlebrook, Nigel, Hill, Brendan, Christie, David R H, Knight, Richard T, Kenny, John, Langton, Christian M, Trapp, Jamie V
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4175818/
https://www.ncbi.nlm.nih.gov/pubmed/26229621
http://dx.doi.org/10.1002/jmrs.24
_version_ 1782336534272278528
author Crowe, Scott B
Kairn, Tanya
Middlebrook, Nigel
Hill, Brendan
Christie, David R H
Knight, Richard T
Kenny, John
Langton, Christian M
Trapp, Jamie V
author_facet Crowe, Scott B
Kairn, Tanya
Middlebrook, Nigel
Hill, Brendan
Christie, David R H
Knight, Richard T
Kenny, John
Langton, Christian M
Trapp, Jamie V
author_sort Crowe, Scott B
collection PubMed
description INTRODUCTION: This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). METHODS: Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. RESULTS: The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. CONCLUSIONS: This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.
format Online
Article
Text
id pubmed-4175818
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-41758182014-09-30 Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy Crowe, Scott B Kairn, Tanya Middlebrook, Nigel Hill, Brendan Christie, David R H Knight, Richard T Kenny, John Langton, Christian M Trapp, Jamie V J Med Radiat Sci Original Articles INTRODUCTION: This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). METHODS: Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. RESULTS: The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. CONCLUSIONS: This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT. Blackwell Publishing Ltd 2013-12 2013-11-19 /pmc/articles/PMC4175818/ /pubmed/26229621 http://dx.doi.org/10.1002/jmrs.24 Text en © 2013 The Authors. Journal of Medical Radiation Sciences published by Wiley Publishing Asia Pty Ltd on behalf of Australian Institute of Radiography and New Zealand Institute of Medical Radiation Technology http://creativecommons.org/licenses/by/2.5/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Crowe, Scott B
Kairn, Tanya
Middlebrook, Nigel
Hill, Brendan
Christie, David R H
Knight, Richard T
Kenny, John
Langton, Christian M
Trapp, Jamie V
Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy
title Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy
title_full Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy
title_fullStr Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy
title_full_unstemmed Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy
title_short Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy
title_sort retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3d conformal, intensity modulated and volumetric modulated arc radiotherapy
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4175818/
https://www.ncbi.nlm.nih.gov/pubmed/26229621
http://dx.doi.org/10.1002/jmrs.24
work_keys_str_mv AT crowescottb retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy
AT kairntanya retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy
AT middlebrooknigel retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy
AT hillbrendan retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy
AT christiedavidrh retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy
AT knightrichardt retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy
AT kennyjohn retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy
AT langtonchristianm retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy
AT trappjamiev retrospectiveevaluationofdosimetricqualityforprostatecarcinomastreatedwith3dconformalintensitymodulatedandvolumetricmodulatedarcradiotherapy