Cargando…
Harmonic ultrasonography for the detection of microlithiasis in the gallbladder
PURPOSE: To validate the use of harmonic ultrasonography (US) in the detection of gallbladder microlithiasis. METHODS: From November 30, 2012, to January 18, 2014, fundamental US (FUS) and harmonic US with a high background noise (HUS-N) were performed for evaluation of gallbladder during the routin...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Ultrasound in Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4176116/ https://www.ncbi.nlm.nih.gov/pubmed/25060185 http://dx.doi.org/10.14366/usg.14024 |
_version_ | 1782336576631603200 |
---|---|
author | Choi, Chul Soon Ku, You Jin Yoon, Dae Young Yun, Eun Joo Seo, Young Lan Lim, Kyoung Ja Baek, Sora Bae, Sang Hoon Nam, Eun Sook |
author_facet | Choi, Chul Soon Ku, You Jin Yoon, Dae Young Yun, Eun Joo Seo, Young Lan Lim, Kyoung Ja Baek, Sora Bae, Sang Hoon Nam, Eun Sook |
author_sort | Choi, Chul Soon |
collection | PubMed |
description | PURPOSE: To validate the use of harmonic ultrasonography (US) in the detection of gallbladder microlithiasis. METHODS: From November 30, 2012, to January 18, 2014, fundamental US (FUS) and harmonic US with a high background noise (HUS-N) were performed for evaluation of gallbladder during the routine abdomen US. During the US, a dot-like stone (or stones) with Brownian motion was regarded as a positive finding of microlithiasis. Fifty-five patients with microlithiasis in the gallbladder detected on US were enrolled as the subjects of a retrospective review. With respect to the obtained images, two abdominal radiologists independently scored the conspicuity of gallbladder microlithiasis on FUS and HUS-N by using a 4-grade scale. The statistical analysis employed a kappa test and a Wilcoxon rank-sum test. RESULTS: For FUS, the conspicuity grades of gallbladder microlithiasis were G1 in 25 and 37, G2 in 21 and 9, G3 in 6 and 6, G4 in 3 and 3 patients, while HUS-N showed G1 in 0 and 0, G2 in 3 and 2, G3 in 12 and 15, and G4 in 40 and 38 patients, respectively, by each of the two radiologists. The kappa value was 0.633 for FUS between the two radiologists and 0.708 for HUS-N. HUS-N showed better conspicuity of gallbladder microlithiasis than FUS with significant P-values of less than 0.001 and 0.001 for the two radiologists, respectively. CONCLUSION: Compared with FUS, HUS-N enables better detection of microlithiasis in the gallbladder. |
format | Online Article Text |
id | pubmed-4176116 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Korean Society of Ultrasound in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-41761162014-10-17 Harmonic ultrasonography for the detection of microlithiasis in the gallbladder Choi, Chul Soon Ku, You Jin Yoon, Dae Young Yun, Eun Joo Seo, Young Lan Lim, Kyoung Ja Baek, Sora Bae, Sang Hoon Nam, Eun Sook Ultrasonography Original Article PURPOSE: To validate the use of harmonic ultrasonography (US) in the detection of gallbladder microlithiasis. METHODS: From November 30, 2012, to January 18, 2014, fundamental US (FUS) and harmonic US with a high background noise (HUS-N) were performed for evaluation of gallbladder during the routine abdomen US. During the US, a dot-like stone (or stones) with Brownian motion was regarded as a positive finding of microlithiasis. Fifty-five patients with microlithiasis in the gallbladder detected on US were enrolled as the subjects of a retrospective review. With respect to the obtained images, two abdominal radiologists independently scored the conspicuity of gallbladder microlithiasis on FUS and HUS-N by using a 4-grade scale. The statistical analysis employed a kappa test and a Wilcoxon rank-sum test. RESULTS: For FUS, the conspicuity grades of gallbladder microlithiasis were G1 in 25 and 37, G2 in 21 and 9, G3 in 6 and 6, G4 in 3 and 3 patients, while HUS-N showed G1 in 0 and 0, G2 in 3 and 2, G3 in 12 and 15, and G4 in 40 and 38 patients, respectively, by each of the two radiologists. The kappa value was 0.633 for FUS between the two radiologists and 0.708 for HUS-N. HUS-N showed better conspicuity of gallbladder microlithiasis than FUS with significant P-values of less than 0.001 and 0.001 for the two radiologists, respectively. CONCLUSION: Compared with FUS, HUS-N enables better detection of microlithiasis in the gallbladder. Korean Society of Ultrasound in Medicine 2014-10 2014-06-28 /pmc/articles/PMC4176116/ /pubmed/25060185 http://dx.doi.org/10.14366/usg.14024 Text en Copyright © 2014 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Choi, Chul Soon Ku, You Jin Yoon, Dae Young Yun, Eun Joo Seo, Young Lan Lim, Kyoung Ja Baek, Sora Bae, Sang Hoon Nam, Eun Sook Harmonic ultrasonography for the detection of microlithiasis in the gallbladder |
title | Harmonic ultrasonography for the detection of microlithiasis in the gallbladder |
title_full | Harmonic ultrasonography for the detection of microlithiasis in the gallbladder |
title_fullStr | Harmonic ultrasonography for the detection of microlithiasis in the gallbladder |
title_full_unstemmed | Harmonic ultrasonography for the detection of microlithiasis in the gallbladder |
title_short | Harmonic ultrasonography for the detection of microlithiasis in the gallbladder |
title_sort | harmonic ultrasonography for the detection of microlithiasis in the gallbladder |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4176116/ https://www.ncbi.nlm.nih.gov/pubmed/25060185 http://dx.doi.org/10.14366/usg.14024 |
work_keys_str_mv | AT choichulsoon harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder AT kuyoujin harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder AT yoondaeyoung harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder AT yuneunjoo harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder AT seoyounglan harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder AT limkyoungja harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder AT baeksora harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder AT baesanghoon harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder AT nameunsook harmonicultrasonographyforthedetectionofmicrolithiasisinthegallbladder |