Cargando…

Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale

Lasers have been proven to be precise tools for bone ablation. Applying no mechanical stress to the patient, they are potentially very suitable for microsurgery on fragile structures such as the inner ear. However, it remains challenging to control the laser-bone ablation without injuring embedded s...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Yaokun, Pfeiffer, Tom, Weller, Marcel, Wieser, Wolfgang, Huber, Robert, Raczkowsky, Jörg, Schipper, Jörg, Wörn, Heinz, Klenzner, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4177734/
https://www.ncbi.nlm.nih.gov/pubmed/25295253
http://dx.doi.org/10.1155/2014/251814
_version_ 1782336824846319616
author Zhang, Yaokun
Pfeiffer, Tom
Weller, Marcel
Wieser, Wolfgang
Huber, Robert
Raczkowsky, Jörg
Schipper, Jörg
Wörn, Heinz
Klenzner, Thomas
author_facet Zhang, Yaokun
Pfeiffer, Tom
Weller, Marcel
Wieser, Wolfgang
Huber, Robert
Raczkowsky, Jörg
Schipper, Jörg
Wörn, Heinz
Klenzner, Thomas
author_sort Zhang, Yaokun
collection PubMed
description Lasers have been proven to be precise tools for bone ablation. Applying no mechanical stress to the patient, they are potentially very suitable for microsurgery on fragile structures such as the inner ear. However, it remains challenging to control the laser-bone ablation without injuring embedded soft tissue. In this work, we demonstrate a closed-loop control of a short-pulsed CO(2) laser to perform laser cochleostomy under the monitoring of an optical coherence tomography (OCT) system. A foresighted detection of the bone-endosteum-perilymph boundary several hundred micrometers before its exposure has been realized. Position and duration of the laser pulses are planned based on the residual bone thickness distribution. OCT itself is also used as a highly accurate tracking system for motion compensation between the target area and the optics. During ex vivo experimental evaluation on fresh porcine cochleae, the ablation process terminated automatically when the thickness of the residual tissue layer uniformly reached a predefined value. The shape of the resulting channel bottom converged to the natural curvature of the endosteal layer without injuring the critical structure. Preliminary measurements in OCT scans indicated that the mean absolute accuracy of the shape approximation was only around 20 μm.
format Online
Article
Text
id pubmed-4177734
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41777342014-10-07 Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale Zhang, Yaokun Pfeiffer, Tom Weller, Marcel Wieser, Wolfgang Huber, Robert Raczkowsky, Jörg Schipper, Jörg Wörn, Heinz Klenzner, Thomas Biomed Res Int Research Article Lasers have been proven to be precise tools for bone ablation. Applying no mechanical stress to the patient, they are potentially very suitable for microsurgery on fragile structures such as the inner ear. However, it remains challenging to control the laser-bone ablation without injuring embedded soft tissue. In this work, we demonstrate a closed-loop control of a short-pulsed CO(2) laser to perform laser cochleostomy under the monitoring of an optical coherence tomography (OCT) system. A foresighted detection of the bone-endosteum-perilymph boundary several hundred micrometers before its exposure has been realized. Position and duration of the laser pulses are planned based on the residual bone thickness distribution. OCT itself is also used as a highly accurate tracking system for motion compensation between the target area and the optics. During ex vivo experimental evaluation on fresh porcine cochleae, the ablation process terminated automatically when the thickness of the residual tissue layer uniformly reached a predefined value. The shape of the resulting channel bottom converged to the natural curvature of the endosteal layer without injuring the critical structure. Preliminary measurements in OCT scans indicated that the mean absolute accuracy of the shape approximation was only around 20 μm. Hindawi Publishing Corporation 2014 2014-09-11 /pmc/articles/PMC4177734/ /pubmed/25295253 http://dx.doi.org/10.1155/2014/251814 Text en Copyright © 2014 Yaokun Zhang et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhang, Yaokun
Pfeiffer, Tom
Weller, Marcel
Wieser, Wolfgang
Huber, Robert
Raczkowsky, Jörg
Schipper, Jörg
Wörn, Heinz
Klenzner, Thomas
Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale
title Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale
title_full Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale
title_fullStr Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale
title_full_unstemmed Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale
title_short Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale
title_sort optical coherence tomography guided laser cochleostomy: towards the accuracy on tens of micrometer scale
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4177734/
https://www.ncbi.nlm.nih.gov/pubmed/25295253
http://dx.doi.org/10.1155/2014/251814
work_keys_str_mv AT zhangyaokun opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale
AT pfeiffertom opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale
AT wellermarcel opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale
AT wieserwolfgang opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale
AT huberrobert opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale
AT raczkowskyjorg opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale
AT schipperjorg opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale
AT wornheinz opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale
AT klenznerthomas opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale