Cargando…
Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale
Lasers have been proven to be precise tools for bone ablation. Applying no mechanical stress to the patient, they are potentially very suitable for microsurgery on fragile structures such as the inner ear. However, it remains challenging to control the laser-bone ablation without injuring embedded s...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4177734/ https://www.ncbi.nlm.nih.gov/pubmed/25295253 http://dx.doi.org/10.1155/2014/251814 |
_version_ | 1782336824846319616 |
---|---|
author | Zhang, Yaokun Pfeiffer, Tom Weller, Marcel Wieser, Wolfgang Huber, Robert Raczkowsky, Jörg Schipper, Jörg Wörn, Heinz Klenzner, Thomas |
author_facet | Zhang, Yaokun Pfeiffer, Tom Weller, Marcel Wieser, Wolfgang Huber, Robert Raczkowsky, Jörg Schipper, Jörg Wörn, Heinz Klenzner, Thomas |
author_sort | Zhang, Yaokun |
collection | PubMed |
description | Lasers have been proven to be precise tools for bone ablation. Applying no mechanical stress to the patient, they are potentially very suitable for microsurgery on fragile structures such as the inner ear. However, it remains challenging to control the laser-bone ablation without injuring embedded soft tissue. In this work, we demonstrate a closed-loop control of a short-pulsed CO(2) laser to perform laser cochleostomy under the monitoring of an optical coherence tomography (OCT) system. A foresighted detection of the bone-endosteum-perilymph boundary several hundred micrometers before its exposure has been realized. Position and duration of the laser pulses are planned based on the residual bone thickness distribution. OCT itself is also used as a highly accurate tracking system for motion compensation between the target area and the optics. During ex vivo experimental evaluation on fresh porcine cochleae, the ablation process terminated automatically when the thickness of the residual tissue layer uniformly reached a predefined value. The shape of the resulting channel bottom converged to the natural curvature of the endosteal layer without injuring the critical structure. Preliminary measurements in OCT scans indicated that the mean absolute accuracy of the shape approximation was only around 20 μm. |
format | Online Article Text |
id | pubmed-4177734 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-41777342014-10-07 Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale Zhang, Yaokun Pfeiffer, Tom Weller, Marcel Wieser, Wolfgang Huber, Robert Raczkowsky, Jörg Schipper, Jörg Wörn, Heinz Klenzner, Thomas Biomed Res Int Research Article Lasers have been proven to be precise tools for bone ablation. Applying no mechanical stress to the patient, they are potentially very suitable for microsurgery on fragile structures such as the inner ear. However, it remains challenging to control the laser-bone ablation without injuring embedded soft tissue. In this work, we demonstrate a closed-loop control of a short-pulsed CO(2) laser to perform laser cochleostomy under the monitoring of an optical coherence tomography (OCT) system. A foresighted detection of the bone-endosteum-perilymph boundary several hundred micrometers before its exposure has been realized. Position and duration of the laser pulses are planned based on the residual bone thickness distribution. OCT itself is also used as a highly accurate tracking system for motion compensation between the target area and the optics. During ex vivo experimental evaluation on fresh porcine cochleae, the ablation process terminated automatically when the thickness of the residual tissue layer uniformly reached a predefined value. The shape of the resulting channel bottom converged to the natural curvature of the endosteal layer without injuring the critical structure. Preliminary measurements in OCT scans indicated that the mean absolute accuracy of the shape approximation was only around 20 μm. Hindawi Publishing Corporation 2014 2014-09-11 /pmc/articles/PMC4177734/ /pubmed/25295253 http://dx.doi.org/10.1155/2014/251814 Text en Copyright © 2014 Yaokun Zhang et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Yaokun Pfeiffer, Tom Weller, Marcel Wieser, Wolfgang Huber, Robert Raczkowsky, Jörg Schipper, Jörg Wörn, Heinz Klenzner, Thomas Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale |
title | Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale |
title_full | Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale |
title_fullStr | Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale |
title_full_unstemmed | Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale |
title_short | Optical Coherence Tomography Guided Laser Cochleostomy: Towards the Accuracy on Tens of Micrometer Scale |
title_sort | optical coherence tomography guided laser cochleostomy: towards the accuracy on tens of micrometer scale |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4177734/ https://www.ncbi.nlm.nih.gov/pubmed/25295253 http://dx.doi.org/10.1155/2014/251814 |
work_keys_str_mv | AT zhangyaokun opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale AT pfeiffertom opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale AT wellermarcel opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale AT wieserwolfgang opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale AT huberrobert opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale AT raczkowskyjorg opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale AT schipperjorg opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale AT wornheinz opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale AT klenznerthomas opticalcoherencetomographyguidedlasercochleostomytowardstheaccuracyontensofmicrometerscale |