Cargando…

Dependence of the Contact Resistance on the Design of Stranded Conductors

During the manufacturing process multi-strand conductors are subject to compressive force and rotation moments. The current distribution in the multi-strand conductors is not uniform and is controlled by the transverse resistivity. This is mainly determined by the contact resistance at the strand cr...

Descripción completa

Detalles Bibliográficos
Autores principales: Zeroukhi, Youcef, Napieralska-Juszczak, Ewa, Vega, Guillaume, Komeza, Krzysztof, Morganti, Fabrice, Wiak, Slawomir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4179016/
https://www.ncbi.nlm.nih.gov/pubmed/25196112
http://dx.doi.org/10.3390/s140813925
Descripción
Sumario:During the manufacturing process multi-strand conductors are subject to compressive force and rotation moments. The current distribution in the multi-strand conductors is not uniform and is controlled by the transverse resistivity. This is mainly determined by the contact resistance at the strand crossovers and inter-strand contact resistance. The surface layer properties, and in particular the crystalline structure and degree of oxidation, are key parameters in determining the transverse resistivity. The experimental set-ups made it possible to find the dependence of contact resistivity as a function of continuous working stresses and cable design. A study based on measurements and numerical simulation is made to identify the contact resistivity functions.