Cargando…

A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement

An in-fiber Mach-Zehnder interferometer (MZI) for high temperature measurement is proposed and experimentally demonstrated. The device is constructed of a piece of thin-core fiber (TCF) sandwiched between two short sections of multimode fiber (MMF), i.e., a MMF-TCF-MMF structure. A well-defined inte...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, Zhongyao, Li, Jiacheng, Qiao, Xueguang, Li, Ling, Yang, Hangzhou, Hu, Manli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4179077/
https://www.ncbi.nlm.nih.gov/pubmed/25093347
http://dx.doi.org/10.3390/s140814210
_version_ 1782337015673520128
author Feng, Zhongyao
Li, Jiacheng
Qiao, Xueguang
Li, Ling
Yang, Hangzhou
Hu, Manli
author_facet Feng, Zhongyao
Li, Jiacheng
Qiao, Xueguang
Li, Ling
Yang, Hangzhou
Hu, Manli
author_sort Feng, Zhongyao
collection PubMed
description An in-fiber Mach-Zehnder interferometer (MZI) for high temperature measurement is proposed and experimentally demonstrated. The device is constructed of a piece of thin-core fiber (TCF) sandwiched between two short sections of multimode fiber (MMF), i.e., a MMF-TCF-MMF structure. A well-defined interference spectrum is obtained owing to the core-mismatch, and the interference dips are sensitive to the ambient temperature. The experimental results show that the proposed interferometer is capable of high temperature measurement up to 875 °C with a sensitivity of 92 pm/°C over repeated measurements. The explored wavelength drop point may limit the measurement range, which can be improved by repeated thermal annealing.
format Online
Article
Text
id pubmed-4179077
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-41790772014-10-02 A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement Feng, Zhongyao Li, Jiacheng Qiao, Xueguang Li, Ling Yang, Hangzhou Hu, Manli Sensors (Basel) Article An in-fiber Mach-Zehnder interferometer (MZI) for high temperature measurement is proposed and experimentally demonstrated. The device is constructed of a piece of thin-core fiber (TCF) sandwiched between two short sections of multimode fiber (MMF), i.e., a MMF-TCF-MMF structure. A well-defined interference spectrum is obtained owing to the core-mismatch, and the interference dips are sensitive to the ambient temperature. The experimental results show that the proposed interferometer is capable of high temperature measurement up to 875 °C with a sensitivity of 92 pm/°C over repeated measurements. The explored wavelength drop point may limit the measurement range, which can be improved by repeated thermal annealing. MDPI 2014-08-04 /pmc/articles/PMC4179077/ /pubmed/25093347 http://dx.doi.org/10.3390/s140814210 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Feng, Zhongyao
Li, Jiacheng
Qiao, Xueguang
Li, Ling
Yang, Hangzhou
Hu, Manli
A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
title A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
title_full A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
title_fullStr A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
title_full_unstemmed A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
title_short A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
title_sort thermally annealed mach-zehnder interferometer for high temperature measurement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4179077/
https://www.ncbi.nlm.nih.gov/pubmed/25093347
http://dx.doi.org/10.3390/s140814210
work_keys_str_mv AT fengzhongyao athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT lijiacheng athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT qiaoxueguang athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT liling athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT yanghangzhou athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT humanli athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT fengzhongyao thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT lijiacheng thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT qiaoxueguang thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT liling thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT yanghangzhou thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement
AT humanli thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement