Cargando…
A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
An in-fiber Mach-Zehnder interferometer (MZI) for high temperature measurement is proposed and experimentally demonstrated. The device is constructed of a piece of thin-core fiber (TCF) sandwiched between two short sections of multimode fiber (MMF), i.e., a MMF-TCF-MMF structure. A well-defined inte...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4179077/ https://www.ncbi.nlm.nih.gov/pubmed/25093347 http://dx.doi.org/10.3390/s140814210 |
_version_ | 1782337015673520128 |
---|---|
author | Feng, Zhongyao Li, Jiacheng Qiao, Xueguang Li, Ling Yang, Hangzhou Hu, Manli |
author_facet | Feng, Zhongyao Li, Jiacheng Qiao, Xueguang Li, Ling Yang, Hangzhou Hu, Manli |
author_sort | Feng, Zhongyao |
collection | PubMed |
description | An in-fiber Mach-Zehnder interferometer (MZI) for high temperature measurement is proposed and experimentally demonstrated. The device is constructed of a piece of thin-core fiber (TCF) sandwiched between two short sections of multimode fiber (MMF), i.e., a MMF-TCF-MMF structure. A well-defined interference spectrum is obtained owing to the core-mismatch, and the interference dips are sensitive to the ambient temperature. The experimental results show that the proposed interferometer is capable of high temperature measurement up to 875 °C with a sensitivity of 92 pm/°C over repeated measurements. The explored wavelength drop point may limit the measurement range, which can be improved by repeated thermal annealing. |
format | Online Article Text |
id | pubmed-4179077 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-41790772014-10-02 A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement Feng, Zhongyao Li, Jiacheng Qiao, Xueguang Li, Ling Yang, Hangzhou Hu, Manli Sensors (Basel) Article An in-fiber Mach-Zehnder interferometer (MZI) for high temperature measurement is proposed and experimentally demonstrated. The device is constructed of a piece of thin-core fiber (TCF) sandwiched between two short sections of multimode fiber (MMF), i.e., a MMF-TCF-MMF structure. A well-defined interference spectrum is obtained owing to the core-mismatch, and the interference dips are sensitive to the ambient temperature. The experimental results show that the proposed interferometer is capable of high temperature measurement up to 875 °C with a sensitivity of 92 pm/°C over repeated measurements. The explored wavelength drop point may limit the measurement range, which can be improved by repeated thermal annealing. MDPI 2014-08-04 /pmc/articles/PMC4179077/ /pubmed/25093347 http://dx.doi.org/10.3390/s140814210 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Feng, Zhongyao Li, Jiacheng Qiao, Xueguang Li, Ling Yang, Hangzhou Hu, Manli A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement |
title | A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement |
title_full | A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement |
title_fullStr | A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement |
title_full_unstemmed | A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement |
title_short | A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement |
title_sort | thermally annealed mach-zehnder interferometer for high temperature measurement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4179077/ https://www.ncbi.nlm.nih.gov/pubmed/25093347 http://dx.doi.org/10.3390/s140814210 |
work_keys_str_mv | AT fengzhongyao athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT lijiacheng athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT qiaoxueguang athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT liling athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT yanghangzhou athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT humanli athermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT fengzhongyao thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT lijiacheng thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT qiaoxueguang thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT liling thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT yanghangzhou thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement AT humanli thermallyannealedmachzehnderinterferometerforhightemperaturemeasurement |