Comparative Diagnostic Accuracy of Ganglion Cell-Inner Plexiform and Retinal Nerve Fiber Layer Thickness Measures by Cirrus and Spectralis Optical Coherence Tomography in Relapsing-Remitting Multiple Sclerosis
Objective. To estimate sensitivity and specificity of several optical coherence tomography (OCT) measurements for detecting retinal thickness changes in patients with relapsing-remitting multiple sclerosis (RRMS), such as macular ganglion cell-inner plexiform layer (GCIPL) thickness measured with Ci...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4182893/ https://www.ncbi.nlm.nih.gov/pubmed/25313352 http://dx.doi.org/10.1155/2014/128517 |
_version_ | 1782337629826580480 |
---|---|
author | González-López, Julio J. Rebolleda, Gema Leal, Marina Oblanca, Noelia Muñoz-Negrete, Francisco J. Costa-Frossard, Lucienne Álvarez-Cermeño, José C. |
author_facet | González-López, Julio J. Rebolleda, Gema Leal, Marina Oblanca, Noelia Muñoz-Negrete, Francisco J. Costa-Frossard, Lucienne Álvarez-Cermeño, José C. |
author_sort | González-López, Julio J. |
collection | PubMed |
description | Objective. To estimate sensitivity and specificity of several optical coherence tomography (OCT) measurements for detecting retinal thickness changes in patients with relapsing-remitting multiple sclerosis (RRMS), such as macular ganglion cell-inner plexiform layer (GCIPL) thickness measured with Cirrus (OCT) and peripapillary retinal nerve fiber layer (pRNFL) thickness measured with Cirrus and Spectralis OCT. Methods. Seventy patients (140 eyes) with RRMS and seventy matched healthy subjects underwent pRNFL and GCIPL thickness analysis using Cirrus OCT and pRNFL using Spectralis OCT. A prospective, cross-sectional evaluation of sensitivities and specificities was performed using latent class analysis due to the absence of a gold standard. Results. GCIPL measures had higher sensitivity and specificity than temporal pRNFL measures obtained with both OCT devices. Average GCIPL thickness was significantly more sensitive than temporal pRNFL by Cirrus (96.34% versus 58.41%) and minimum GCIPL thickness was significantly more sensitive than temporal pRNFL by Spectralis (96.41% versus 69.69%). Generalised estimating equation analysis revealed that age (P = 0.030), optic neuritis antecedent (P = 0.001), and disease duration (P = 0.002) were significantly associated with abnormal results in average GCIPL thickness. Conclusion. Average and minimum GCIPL measurements had significantly better sensitivity to detect retinal thickness changes in RRMS than temporal pRNFL thickness measured by Cirrus and Spectralis OCT, respectively. |
format | Online Article Text |
id | pubmed-4182893 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-41828932014-10-13 Comparative Diagnostic Accuracy of Ganglion Cell-Inner Plexiform and Retinal Nerve Fiber Layer Thickness Measures by Cirrus and Spectralis Optical Coherence Tomography in Relapsing-Remitting Multiple Sclerosis González-López, Julio J. Rebolleda, Gema Leal, Marina Oblanca, Noelia Muñoz-Negrete, Francisco J. Costa-Frossard, Lucienne Álvarez-Cermeño, José C. Biomed Res Int Clinical Study Objective. To estimate sensitivity and specificity of several optical coherence tomography (OCT) measurements for detecting retinal thickness changes in patients with relapsing-remitting multiple sclerosis (RRMS), such as macular ganglion cell-inner plexiform layer (GCIPL) thickness measured with Cirrus (OCT) and peripapillary retinal nerve fiber layer (pRNFL) thickness measured with Cirrus and Spectralis OCT. Methods. Seventy patients (140 eyes) with RRMS and seventy matched healthy subjects underwent pRNFL and GCIPL thickness analysis using Cirrus OCT and pRNFL using Spectralis OCT. A prospective, cross-sectional evaluation of sensitivities and specificities was performed using latent class analysis due to the absence of a gold standard. Results. GCIPL measures had higher sensitivity and specificity than temporal pRNFL measures obtained with both OCT devices. Average GCIPL thickness was significantly more sensitive than temporal pRNFL by Cirrus (96.34% versus 58.41%) and minimum GCIPL thickness was significantly more sensitive than temporal pRNFL by Spectralis (96.41% versus 69.69%). Generalised estimating equation analysis revealed that age (P = 0.030), optic neuritis antecedent (P = 0.001), and disease duration (P = 0.002) were significantly associated with abnormal results in average GCIPL thickness. Conclusion. Average and minimum GCIPL measurements had significantly better sensitivity to detect retinal thickness changes in RRMS than temporal pRNFL thickness measured by Cirrus and Spectralis OCT, respectively. Hindawi Publishing Corporation 2014 2014-09-18 /pmc/articles/PMC4182893/ /pubmed/25313352 http://dx.doi.org/10.1155/2014/128517 Text en Copyright © 2014 Julio J. González-López et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study González-López, Julio J. Rebolleda, Gema Leal, Marina Oblanca, Noelia Muñoz-Negrete, Francisco J. Costa-Frossard, Lucienne Álvarez-Cermeño, José C. Comparative Diagnostic Accuracy of Ganglion Cell-Inner Plexiform and Retinal Nerve Fiber Layer Thickness Measures by Cirrus and Spectralis Optical Coherence Tomography in Relapsing-Remitting Multiple Sclerosis |
title | Comparative Diagnostic Accuracy of Ganglion Cell-Inner Plexiform and Retinal Nerve Fiber Layer Thickness Measures by Cirrus and Spectralis Optical Coherence Tomography in Relapsing-Remitting Multiple Sclerosis |
title_full | Comparative Diagnostic Accuracy of Ganglion Cell-Inner Plexiform and Retinal Nerve Fiber Layer Thickness Measures by Cirrus and Spectralis Optical Coherence Tomography in Relapsing-Remitting Multiple Sclerosis |
title_fullStr | Comparative Diagnostic Accuracy of Ganglion Cell-Inner Plexiform and Retinal Nerve Fiber Layer Thickness Measures by Cirrus and Spectralis Optical Coherence Tomography in Relapsing-Remitting Multiple Sclerosis |
title_full_unstemmed | Comparative Diagnostic Accuracy of Ganglion Cell-Inner Plexiform and Retinal Nerve Fiber Layer Thickness Measures by Cirrus and Spectralis Optical Coherence Tomography in Relapsing-Remitting Multiple Sclerosis |
title_short | Comparative Diagnostic Accuracy of Ganglion Cell-Inner Plexiform and Retinal Nerve Fiber Layer Thickness Measures by Cirrus and Spectralis Optical Coherence Tomography in Relapsing-Remitting Multiple Sclerosis |
title_sort | comparative diagnostic accuracy of ganglion cell-inner plexiform and retinal nerve fiber layer thickness measures by cirrus and spectralis optical coherence tomography in relapsing-remitting multiple sclerosis |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4182893/ https://www.ncbi.nlm.nih.gov/pubmed/25313352 http://dx.doi.org/10.1155/2014/128517 |
work_keys_str_mv | AT gonzalezlopezjulioj comparativediagnosticaccuracyofganglioncellinnerplexiformandretinalnervefiberlayerthicknessmeasuresbycirrusandspectralisopticalcoherencetomographyinrelapsingremittingmultiplesclerosis AT rebolledagema comparativediagnosticaccuracyofganglioncellinnerplexiformandretinalnervefiberlayerthicknessmeasuresbycirrusandspectralisopticalcoherencetomographyinrelapsingremittingmultiplesclerosis AT lealmarina comparativediagnosticaccuracyofganglioncellinnerplexiformandretinalnervefiberlayerthicknessmeasuresbycirrusandspectralisopticalcoherencetomographyinrelapsingremittingmultiplesclerosis AT oblancanoelia comparativediagnosticaccuracyofganglioncellinnerplexiformandretinalnervefiberlayerthicknessmeasuresbycirrusandspectralisopticalcoherencetomographyinrelapsingremittingmultiplesclerosis AT munoznegretefranciscoj comparativediagnosticaccuracyofganglioncellinnerplexiformandretinalnervefiberlayerthicknessmeasuresbycirrusandspectralisopticalcoherencetomographyinrelapsingremittingmultiplesclerosis AT costafrossardlucienne comparativediagnosticaccuracyofganglioncellinnerplexiformandretinalnervefiberlayerthicknessmeasuresbycirrusandspectralisopticalcoherencetomographyinrelapsingremittingmultiplesclerosis AT alvarezcermenojosec comparativediagnosticaccuracyofganglioncellinnerplexiformandretinalnervefiberlayerthicknessmeasuresbycirrusandspectralisopticalcoherencetomographyinrelapsingremittingmultiplesclerosis |