Cargando…
Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis
Idiopathic bilateral vocal cord paralysis (VCP) is a rare and difficult condition often undiagnosed and frequently confused with asthma and other respiratory conditions. Accurate diagnosis is crucial since 80% of cases patients require surgical intervention, such as tracheostomy or laser surgery, to...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4184725/ https://www.ncbi.nlm.nih.gov/pubmed/25473555 http://dx.doi.org/10.1002/rcr2.37 |
_version_ | 1782337900653838336 |
---|---|
author | Ruane, Laurence E Lau, Kenneth K Low, Kathy Crossett, Marcus Vallance, Neil Bardin, Philip G |
author_facet | Ruane, Laurence E Lau, Kenneth K Low, Kathy Crossett, Marcus Vallance, Neil Bardin, Philip G |
author_sort | Ruane, Laurence E |
collection | PubMed |
description | Idiopathic bilateral vocal cord paralysis (VCP) is a rare and difficult condition often undiagnosed and frequently confused with asthma and other respiratory conditions. Accurate diagnosis is crucial since 80% of cases patients require surgical intervention, such as tracheostomy or laser surgery, to relieve symptoms. The “gold standard” for diagnosing VCP has been laryngoscopy. In this case study, we demonstrate for the first time that idiopathic bilateral VCP can be accurately diagnosed by means of a novel noninvasive methodology: dynamic volume 320-slice computed tomography larynx. Three-dimensional reconstruction of laryngeal motion during the breathing cycle permitted functional assessment of the larynx showing absence of vocal cord movements. The new methodology may be valuable for noninvasive diagnosis of vocal cord movement disorders before and for follow-up after surgery. |
format | Online Article Text |
id | pubmed-4184725 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Blackwell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-41847252014-12-03 Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis Ruane, Laurence E Lau, Kenneth K Low, Kathy Crossett, Marcus Vallance, Neil Bardin, Philip G Respirol Case Rep Case Reports Idiopathic bilateral vocal cord paralysis (VCP) is a rare and difficult condition often undiagnosed and frequently confused with asthma and other respiratory conditions. Accurate diagnosis is crucial since 80% of cases patients require surgical intervention, such as tracheostomy or laser surgery, to relieve symptoms. The “gold standard” for diagnosing VCP has been laryngoscopy. In this case study, we demonstrate for the first time that idiopathic bilateral VCP can be accurately diagnosed by means of a novel noninvasive methodology: dynamic volume 320-slice computed tomography larynx. Three-dimensional reconstruction of laryngeal motion during the breathing cycle permitted functional assessment of the larynx showing absence of vocal cord movements. The new methodology may be valuable for noninvasive diagnosis of vocal cord movement disorders before and for follow-up after surgery. Blackwell Publishing Ltd 2014-03 2013-12-20 /pmc/articles/PMC4184725/ /pubmed/25473555 http://dx.doi.org/10.1002/rcr2.37 Text en © 2013 The Authors. Respirology Case Reports published by John Wiley & Sons Ltd on behalf of The Asian Pacific Society of Respirology. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Case Reports Ruane, Laurence E Lau, Kenneth K Low, Kathy Crossett, Marcus Vallance, Neil Bardin, Philip G Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis |
title | Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis |
title_full | Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis |
title_fullStr | Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis |
title_full_unstemmed | Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis |
title_short | Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis |
title_sort | dynamic 320-slice ct larynx for detection and management of idiopathic bilateral vocal cord paralysis |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4184725/ https://www.ncbi.nlm.nih.gov/pubmed/25473555 http://dx.doi.org/10.1002/rcr2.37 |
work_keys_str_mv | AT ruanelaurencee dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis AT laukennethk dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis AT lowkathy dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis AT crossettmarcus dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis AT vallanceneil dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis AT bardinphilipg dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis |