Cargando…

Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis

Idiopathic bilateral vocal cord paralysis (VCP) is a rare and difficult condition often undiagnosed and frequently confused with asthma and other respiratory conditions. Accurate diagnosis is crucial since 80% of cases patients require surgical intervention, such as tracheostomy or laser surgery, to...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruane, Laurence E, Lau, Kenneth K, Low, Kathy, Crossett, Marcus, Vallance, Neil, Bardin, Philip G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4184725/
https://www.ncbi.nlm.nih.gov/pubmed/25473555
http://dx.doi.org/10.1002/rcr2.37
_version_ 1782337900653838336
author Ruane, Laurence E
Lau, Kenneth K
Low, Kathy
Crossett, Marcus
Vallance, Neil
Bardin, Philip G
author_facet Ruane, Laurence E
Lau, Kenneth K
Low, Kathy
Crossett, Marcus
Vallance, Neil
Bardin, Philip G
author_sort Ruane, Laurence E
collection PubMed
description Idiopathic bilateral vocal cord paralysis (VCP) is a rare and difficult condition often undiagnosed and frequently confused with asthma and other respiratory conditions. Accurate diagnosis is crucial since 80% of cases patients require surgical intervention, such as tracheostomy or laser surgery, to relieve symptoms. The “gold standard” for diagnosing VCP has been laryngoscopy. In this case study, we demonstrate for the first time that idiopathic bilateral VCP can be accurately diagnosed by means of a novel noninvasive methodology: dynamic volume 320-slice computed tomography larynx. Three-dimensional reconstruction of laryngeal motion during the breathing cycle permitted functional assessment of the larynx showing absence of vocal cord movements. The new methodology may be valuable for noninvasive diagnosis of vocal cord movement disorders before and for follow-up after surgery.
format Online
Article
Text
id pubmed-4184725
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-41847252014-12-03 Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis Ruane, Laurence E Lau, Kenneth K Low, Kathy Crossett, Marcus Vallance, Neil Bardin, Philip G Respirol Case Rep Case Reports Idiopathic bilateral vocal cord paralysis (VCP) is a rare and difficult condition often undiagnosed and frequently confused with asthma and other respiratory conditions. Accurate diagnosis is crucial since 80% of cases patients require surgical intervention, such as tracheostomy or laser surgery, to relieve symptoms. The “gold standard” for diagnosing VCP has been laryngoscopy. In this case study, we demonstrate for the first time that idiopathic bilateral VCP can be accurately diagnosed by means of a novel noninvasive methodology: dynamic volume 320-slice computed tomography larynx. Three-dimensional reconstruction of laryngeal motion during the breathing cycle permitted functional assessment of the larynx showing absence of vocal cord movements. The new methodology may be valuable for noninvasive diagnosis of vocal cord movement disorders before and for follow-up after surgery. Blackwell Publishing Ltd 2014-03 2013-12-20 /pmc/articles/PMC4184725/ /pubmed/25473555 http://dx.doi.org/10.1002/rcr2.37 Text en © 2013 The Authors. Respirology Case Reports published by John Wiley & Sons Ltd on behalf of The Asian Pacific Society of Respirology. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Case Reports
Ruane, Laurence E
Lau, Kenneth K
Low, Kathy
Crossett, Marcus
Vallance, Neil
Bardin, Philip G
Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis
title Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis
title_full Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis
title_fullStr Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis
title_full_unstemmed Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis
title_short Dynamic 320-slice CT larynx for detection and management of idiopathic bilateral vocal cord paralysis
title_sort dynamic 320-slice ct larynx for detection and management of idiopathic bilateral vocal cord paralysis
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4184725/
https://www.ncbi.nlm.nih.gov/pubmed/25473555
http://dx.doi.org/10.1002/rcr2.37
work_keys_str_mv AT ruanelaurencee dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis
AT laukennethk dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis
AT lowkathy dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis
AT crossettmarcus dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis
AT vallanceneil dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis
AT bardinphilipg dynamic320slicectlarynxfordetectionandmanagementofidiopathicbilateralvocalcordparalysis