Cargando…

Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations

[Image: see text] A Structures for Lossless Ion Manipulations (SLIM) module that allows ion mobility separations and the switching of ions between alternative drift paths is described. The SLIM switch component has a “Tee” configuration and allows the efficient switching of ions between a linear pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Webb, Ian K., Garimella, Sandilya V. B., Tolmachev, Aleksey V., Chen, Tsung-Chi, Zhang, Xinyu, Cox, Jonathan T., Norheim, Randolph V., Prost, Spencer A., LaMarche, Brian, Anderson, Gordon A., Ibrahim, Yehia M., Smith, Richard D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4188271/
https://www.ncbi.nlm.nih.gov/pubmed/25222548
http://dx.doi.org/10.1021/ac502139e
_version_ 1782338228604370944
author Webb, Ian K.
Garimella, Sandilya V. B.
Tolmachev, Aleksey V.
Chen, Tsung-Chi
Zhang, Xinyu
Cox, Jonathan T.
Norheim, Randolph V.
Prost, Spencer A.
LaMarche, Brian
Anderson, Gordon A.
Ibrahim, Yehia M.
Smith, Richard D.
author_facet Webb, Ian K.
Garimella, Sandilya V. B.
Tolmachev, Aleksey V.
Chen, Tsung-Chi
Zhang, Xinyu
Cox, Jonathan T.
Norheim, Randolph V.
Prost, Spencer A.
LaMarche, Brian
Anderson, Gordon A.
Ibrahim, Yehia M.
Smith, Richard D.
author_sort Webb, Ian K.
collection PubMed
description [Image: see text] A Structures for Lossless Ion Manipulations (SLIM) module that allows ion mobility separations and the switching of ions between alternative drift paths is described. The SLIM switch component has a “Tee” configuration and allows the efficient switching of ions between a linear path and a 90-degree bend. By controlling switching times, ions can be efficiently directed to an alternative channel as a function of their mobilities. In the initial evaluation the switch is used in a static mode and shown compatible with high performance ion mobility separations at 4 Torr. In the dynamic mode, we show that mobility-selected ions can be switched into the alternative channel, and that various ion species can be independently selected based on their mobilities for time-of-flight mass spectrometer (TOF MS) IMS detection and mass analysis. This development also provides the basis of, for example, the selection of specific mobilities for storage and accumulation, and the key component of modules for the assembly of SLIM devices enabling much more complex sequences of ion manipulations.
format Online
Article
Text
id pubmed-4188271
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-41882712015-09-15 Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations Webb, Ian K. Garimella, Sandilya V. B. Tolmachev, Aleksey V. Chen, Tsung-Chi Zhang, Xinyu Cox, Jonathan T. Norheim, Randolph V. Prost, Spencer A. LaMarche, Brian Anderson, Gordon A. Ibrahim, Yehia M. Smith, Richard D. Anal Chem [Image: see text] A Structures for Lossless Ion Manipulations (SLIM) module that allows ion mobility separations and the switching of ions between alternative drift paths is described. The SLIM switch component has a “Tee” configuration and allows the efficient switching of ions between a linear path and a 90-degree bend. By controlling switching times, ions can be efficiently directed to an alternative channel as a function of their mobilities. In the initial evaluation the switch is used in a static mode and shown compatible with high performance ion mobility separations at 4 Torr. In the dynamic mode, we show that mobility-selected ions can be switched into the alternative channel, and that various ion species can be independently selected based on their mobilities for time-of-flight mass spectrometer (TOF MS) IMS detection and mass analysis. This development also provides the basis of, for example, the selection of specific mobilities for storage and accumulation, and the key component of modules for the assembly of SLIM devices enabling much more complex sequences of ion manipulations. American Chemical Society 2014-09-15 2014-10-07 /pmc/articles/PMC4188271/ /pubmed/25222548 http://dx.doi.org/10.1021/ac502139e Text en Copyright © 2014 American Chemical Society Terms of Use (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html)
spellingShingle Webb, Ian K.
Garimella, Sandilya V. B.
Tolmachev, Aleksey V.
Chen, Tsung-Chi
Zhang, Xinyu
Cox, Jonathan T.
Norheim, Randolph V.
Prost, Spencer A.
LaMarche, Brian
Anderson, Gordon A.
Ibrahim, Yehia M.
Smith, Richard D.
Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations
title Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations
title_full Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations
title_fullStr Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations
title_full_unstemmed Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations
title_short Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations
title_sort mobility-resolved ion selection in uniform drift field ion mobility spectrometry/mass spectrometry: dynamic switching in structures for lossless ion manipulations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4188271/
https://www.ncbi.nlm.nih.gov/pubmed/25222548
http://dx.doi.org/10.1021/ac502139e
work_keys_str_mv AT webbiank mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT garimellasandilyavb mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT tolmachevalekseyv mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT chentsungchi mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT zhangxinyu mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT coxjonathant mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT norheimrandolphv mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT prostspencera mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT lamarchebrian mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT andersongordona mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT ibrahimyehiam mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations
AT smithrichardd mobilityresolvedionselectioninuniformdriftfieldionmobilityspectrometrymassspectrometrydynamicswitchinginstructuresforlosslessionmanipulations