Cargando…
X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage
PURPOSE: The aim of the study was to investigate microstructural changes occurring in unilateral renal ischemia-reperfusion injury in a murine animal model using synchrotron radiation. MATERIAL AND METHODS: The effects of renal ischemia-reperfusion were investigated in a murine animal model of unila...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4192129/ https://www.ncbi.nlm.nih.gov/pubmed/25299243 http://dx.doi.org/10.1371/journal.pone.0109562 |
_version_ | 1782338742549217280 |
---|---|
author | Velroyen, Astrid Bech, Martin Zanette, Irene Schwarz, Jolanda Rack, Alexander Tympner, Christiane Herrler, Tanja Staab-Weijnitz, Claudia Braunagel, Margarita Reiser, Maximilian Bamberg, Fabian Pfeiffer, Franz Notohamiprodjo, Mike |
author_facet | Velroyen, Astrid Bech, Martin Zanette, Irene Schwarz, Jolanda Rack, Alexander Tympner, Christiane Herrler, Tanja Staab-Weijnitz, Claudia Braunagel, Margarita Reiser, Maximilian Bamberg, Fabian Pfeiffer, Franz Notohamiprodjo, Mike |
author_sort | Velroyen, Astrid |
collection | PubMed |
description | PURPOSE: The aim of the study was to investigate microstructural changes occurring in unilateral renal ischemia-reperfusion injury in a murine animal model using synchrotron radiation. MATERIAL AND METHODS: The effects of renal ischemia-reperfusion were investigated in a murine animal model of unilateral ischemia. Kidney samples were harvested on day 18. Grating-Based Phase-Contrast Imaging (GB-PCI) of the paraffin-embedded kidney samples was performed at a Synchrotron Radiation Facility (beam energy of 19 keV). To obtain phase information, a two-grating Talbot interferometer was used applying the phase stepping technique. The imaging system provided an effective pixel size of 7.5 µm. The resulting attenuation and differential phase projections were tomographically reconstructed using filtered back-projection. Semi-automated segmentation and volumetry and correlation to histopathology were performed. RESULTS: GB-PCI provided good discrimination of the cortex, outer and inner medulla in non-ischemic control kidneys. Post-ischemic kidneys showed a reduced compartmental differentiation, particularly of the outer stripe of the outer medulla, which could not be differentiated from the inner stripe. Compared to the contralateral kidney, after ischemia a volume loss was detected, while the inner medulla mainly retained its volume (ratio 0.94). Post-ischemic kidneys exhibited severe tissue damage as evidenced by tubular atrophy and dilatation, moderate inflammatory infiltration, loss of brush borders and tubular protein cylinders. CONCLUSION: In conclusion GB-PCI with synchrotron radiation allows for non-destructive microstructural assessment of parenchymal kidney disease and vessel architecture. If translation to lab-based approaches generates sufficient density resolution, and with a time-optimized image analysis protocol, GB-PCI may ultimately serve as a non-invasive, non-enhanced alternative for imaging of pathological changes of the kidney. |
format | Online Article Text |
id | pubmed-4192129 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-41921292014-10-14 X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage Velroyen, Astrid Bech, Martin Zanette, Irene Schwarz, Jolanda Rack, Alexander Tympner, Christiane Herrler, Tanja Staab-Weijnitz, Claudia Braunagel, Margarita Reiser, Maximilian Bamberg, Fabian Pfeiffer, Franz Notohamiprodjo, Mike PLoS One Research Article PURPOSE: The aim of the study was to investigate microstructural changes occurring in unilateral renal ischemia-reperfusion injury in a murine animal model using synchrotron radiation. MATERIAL AND METHODS: The effects of renal ischemia-reperfusion were investigated in a murine animal model of unilateral ischemia. Kidney samples were harvested on day 18. Grating-Based Phase-Contrast Imaging (GB-PCI) of the paraffin-embedded kidney samples was performed at a Synchrotron Radiation Facility (beam energy of 19 keV). To obtain phase information, a two-grating Talbot interferometer was used applying the phase stepping technique. The imaging system provided an effective pixel size of 7.5 µm. The resulting attenuation and differential phase projections were tomographically reconstructed using filtered back-projection. Semi-automated segmentation and volumetry and correlation to histopathology were performed. RESULTS: GB-PCI provided good discrimination of the cortex, outer and inner medulla in non-ischemic control kidneys. Post-ischemic kidneys showed a reduced compartmental differentiation, particularly of the outer stripe of the outer medulla, which could not be differentiated from the inner stripe. Compared to the contralateral kidney, after ischemia a volume loss was detected, while the inner medulla mainly retained its volume (ratio 0.94). Post-ischemic kidneys exhibited severe tissue damage as evidenced by tubular atrophy and dilatation, moderate inflammatory infiltration, loss of brush borders and tubular protein cylinders. CONCLUSION: In conclusion GB-PCI with synchrotron radiation allows for non-destructive microstructural assessment of parenchymal kidney disease and vessel architecture. If translation to lab-based approaches generates sufficient density resolution, and with a time-optimized image analysis protocol, GB-PCI may ultimately serve as a non-invasive, non-enhanced alternative for imaging of pathological changes of the kidney. Public Library of Science 2014-10-09 /pmc/articles/PMC4192129/ /pubmed/25299243 http://dx.doi.org/10.1371/journal.pone.0109562 Text en © 2014 Velroyen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Velroyen, Astrid Bech, Martin Zanette, Irene Schwarz, Jolanda Rack, Alexander Tympner, Christiane Herrler, Tanja Staab-Weijnitz, Claudia Braunagel, Margarita Reiser, Maximilian Bamberg, Fabian Pfeiffer, Franz Notohamiprodjo, Mike X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage |
title | X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage |
title_full | X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage |
title_fullStr | X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage |
title_full_unstemmed | X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage |
title_short | X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage |
title_sort | x-ray phase-contrast tomography of renal ischemia-reperfusion damage |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4192129/ https://www.ncbi.nlm.nih.gov/pubmed/25299243 http://dx.doi.org/10.1371/journal.pone.0109562 |
work_keys_str_mv | AT velroyenastrid xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT bechmartin xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT zanetteirene xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT schwarzjolanda xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT rackalexander xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT tympnerchristiane xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT herrlertanja xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT staabweijnitzclaudia xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT braunagelmargarita xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT reisermaximilian xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT bambergfabian xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT pfeifferfranz xrayphasecontrasttomographyofrenalischemiareperfusiondamage AT notohamiprodjomike xrayphasecontrasttomographyofrenalischemiareperfusiondamage |