Cargando…
The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management
BACKGROUND: Real-time patient respiratory mechanics estimation can be used to guide mechanical ventilation settings, particularly, positive end-expiratory pressure (PEEP). This work presents a software, Clinical Utilisation of Respiratory Elastance (CURE Soft), using a time-varying respiratory elast...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4192763/ https://www.ncbi.nlm.nih.gov/pubmed/25270094 http://dx.doi.org/10.1186/1475-925X-13-140 |
_version_ | 1782338833340170240 |
---|---|
author | Szlavecz, Akos Chiew, Yeong Shiong Redmond, Daniel Beatson, Alex Glassenbury, Daniel Corbett, Simon Major, Vincent Pretty, Christopher Shaw, Geoffrey M Benyo, Balazs Desaive, Thomas Chase, J Geoffrey |
author_facet | Szlavecz, Akos Chiew, Yeong Shiong Redmond, Daniel Beatson, Alex Glassenbury, Daniel Corbett, Simon Major, Vincent Pretty, Christopher Shaw, Geoffrey M Benyo, Balazs Desaive, Thomas Chase, J Geoffrey |
author_sort | Szlavecz, Akos |
collection | PubMed |
description | BACKGROUND: Real-time patient respiratory mechanics estimation can be used to guide mechanical ventilation settings, particularly, positive end-expiratory pressure (PEEP). This work presents a software, Clinical Utilisation of Respiratory Elastance (CURE Soft), using a time-varying respiratory elastance model to offer this ability to aid in mechanical ventilation treatment. IMPLEMENTATION: CURE Soft is a desktop application developed in JAVA. It has two modes of operation, 1) Online real-time monitoring decision support and, 2) Offline for user education purposes, auditing, or reviewing patient care. The CURE Soft has been tested in mechanically ventilated patients with respiratory failure. The clinical protocol, software testing and use of the data were approved by the New Zealand Southern Regional Ethics Committee. RESULTS AND DISCUSSION: Using CURE Soft, patient’s respiratory mechanics response to treatment and clinical protocol were monitored. Results showed that the patient’s respiratory elastance (Stiffness) changed with the use of muscle relaxants, and responded differently to ventilator settings. This information can be used to guide mechanical ventilation therapy and titrate optimal ventilator PEEP. CONCLUSION: CURE Soft enables real-time calculation of model-based respiratory mechanics for mechanically ventilated patients. Results showed that the system is able to provide detailed, previously unavailable information on patient-specific respiratory mechanics and response to therapy in real-time. The additional insight available to clinicians provides the potential for improved decision-making, and thus improved patient care and outcomes. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/1475-925X-13-140) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4192763 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-41927632014-10-11 The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management Szlavecz, Akos Chiew, Yeong Shiong Redmond, Daniel Beatson, Alex Glassenbury, Daniel Corbett, Simon Major, Vincent Pretty, Christopher Shaw, Geoffrey M Benyo, Balazs Desaive, Thomas Chase, J Geoffrey Biomed Eng Online Software BACKGROUND: Real-time patient respiratory mechanics estimation can be used to guide mechanical ventilation settings, particularly, positive end-expiratory pressure (PEEP). This work presents a software, Clinical Utilisation of Respiratory Elastance (CURE Soft), using a time-varying respiratory elastance model to offer this ability to aid in mechanical ventilation treatment. IMPLEMENTATION: CURE Soft is a desktop application developed in JAVA. It has two modes of operation, 1) Online real-time monitoring decision support and, 2) Offline for user education purposes, auditing, or reviewing patient care. The CURE Soft has been tested in mechanically ventilated patients with respiratory failure. The clinical protocol, software testing and use of the data were approved by the New Zealand Southern Regional Ethics Committee. RESULTS AND DISCUSSION: Using CURE Soft, patient’s respiratory mechanics response to treatment and clinical protocol were monitored. Results showed that the patient’s respiratory elastance (Stiffness) changed with the use of muscle relaxants, and responded differently to ventilator settings. This information can be used to guide mechanical ventilation therapy and titrate optimal ventilator PEEP. CONCLUSION: CURE Soft enables real-time calculation of model-based respiratory mechanics for mechanically ventilated patients. Results showed that the system is able to provide detailed, previously unavailable information on patient-specific respiratory mechanics and response to therapy in real-time. The additional insight available to clinicians provides the potential for improved decision-making, and thus improved patient care and outcomes. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/1475-925X-13-140) contains supplementary material, which is available to authorized users. BioMed Central 2014-09-30 /pmc/articles/PMC4192763/ /pubmed/25270094 http://dx.doi.org/10.1186/1475-925X-13-140 Text en © Szlavecz et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Software Szlavecz, Akos Chiew, Yeong Shiong Redmond, Daniel Beatson, Alex Glassenbury, Daniel Corbett, Simon Major, Vincent Pretty, Christopher Shaw, Geoffrey M Benyo, Balazs Desaive, Thomas Chase, J Geoffrey The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management |
title | The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management |
title_full | The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management |
title_fullStr | The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management |
title_full_unstemmed | The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management |
title_short | The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management |
title_sort | clinical utilisation of respiratory elastance software (cure soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management |
topic | Software |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4192763/ https://www.ncbi.nlm.nih.gov/pubmed/25270094 http://dx.doi.org/10.1186/1475-925X-13-140 |
work_keys_str_mv | AT szlaveczakos theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT chiewyeongshiong theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT redmonddaniel theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT beatsonalex theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT glassenburydaniel theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT corbettsimon theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT majorvincent theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT prettychristopher theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT shawgeoffreym theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT benyobalazs theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT desaivethomas theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT chasejgeoffrey theclinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT szlaveczakos clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT chiewyeongshiong clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT redmonddaniel clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT beatsonalex clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT glassenburydaniel clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT corbettsimon clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT majorvincent clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT prettychristopher clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT shawgeoffreym clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT benyobalazs clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT desaivethomas clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement AT chasejgeoffrey clinicalutilisationofrespiratoryelastancesoftwarecuresoftabedsidesoftwareforrealtimerespiratorymechanicsmonitoringandmechanicalventilationmanagement |